A critical evaluation of the planning target volume for 3-D conformal radiotherapy of prostate cancer

被引:84
作者
Tinger, A [1 ]
Michalski, JM [1 ]
Cheng, A [1 ]
Low, DA [1 ]
Zhu, R [1 ]
Bosch, WR [1 ]
Purdy, JA [1 ]
Perez, CA [1 ]
机构
[1] Washington Univ, Sch Med, Barnes Jewish Hosp, Mallinckrodt Inst Radiol,Radiat Oncol Ctr, St Louis, MO USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1998年 / 42卷 / 01期
关键词
radiotherapy; 3D conformal; prostate cancer; uncertainty; organ motion; treatment planning;
D O I
10.1016/S0360-3016(98)00189-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To determine an adequate planning target volume (PTV) margin for three-dimensional conformal radiotherapy (3D CRT) of prostate cancer, the uncertainties in the internal positions of the prostate and seminal vesicles (SV) and in the treatment setups were measured. Methods and Materials: Weekly computed tomography (CT) scans of the pelvis (n = 51) and daily electronic portal images (n = 1630) were reviewed for eight patients who received seven-held 3D CRT for prostate cancer. The CT scans were registered in three dimensions to the original planning CT scan using commercially available software to measure the center-of volume (COV) motion of the prostate and SV. The daily portal images were registered to the corresponding simulation films to measure the setup displacements. The standard deviation (SD) of the internal organ motions was added to the SD of the setups in quadrature to determine the total uncertainty. Positive directions were left, anterior, and superior. Rotations necessary to register the CT scans and portal images were minimal and not further analyzed. Results: The mean motion for the COV of the prostate +/- the SD was 0 +/- 0.9 mm in the left-right (LR), 0.5 +/- 2.6 mm in the anterior-posterior (AP), and 1.5 +/- 3.9 mm in the superior-inferior (SI) directions. The mean motion for the COV of the SV a the SD was 0.3 +/- 1.7 mm in the LR, 0.7 +/- 3.8 mm in the AP, and 0.9 +/- 3.5 mm in the SI directions. For all patients the mean isocenter displacement a the SD was 0 +/- 3.1 mm in the LR, 1.4 +/- 3.0 mm in the AP, and -0.4 +/- 2.1 mm in the SI directions. The total uncertainty for the prostate was 3.2 mm, 4.0 mm, and 4.4 mm in the LR, AP, and SI directions, respectively. For the SV, the total uncertainty was 3.5, 4.8, and 4.1 mm in the LR, AP, and SI directions, respectively. Conclusions: PTV margins of 10 to 16 mm are required to encompass all (99%) possible positions of the prostate or SV during 3D CRT. PTV margins of 7 to 11 mm will encompass the measured uncertainties with a 95% probability. PTV margins of 5 mm may not adequately cover the intended volume. (C) 1998 Elsevier Science Inc.
引用
收藏
页码:213 / 221
页数:9
相关论文
共 31 条
[1]   Tumor and target delineation: Current research and future challenges [J].
AustinSeymour, M ;
Chen, GTY ;
Rosenman, J ;
Michalski, J ;
Lindsley, K ;
Goitein, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1041-1052
[2]  
BAGSHAW MA, 1985, UROLOGY, V25, P17
[3]   MEASUREMENT OF PROSTATE MOVEMENT OVER THE COURSE OF ROUTINE RADIOTHERAPY USING IMPLANTED MARKERS [J].
BALTER, JM ;
SANDLER, HM ;
LAM, K ;
BREE, RL ;
LICHTER, AS ;
TENHAKEN, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01) :113-118
[4]   Analysis of prostate and seminal vesicle motion: Implications for treatment planning [J].
Beard, CJ ;
Kijewski, P ;
Bussiere, M ;
Gelman, R ;
Gladstone, D ;
Shaffer, K ;
Plunkett, M ;
Costello, P ;
Coleman, CN .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (02) :451-458
[5]   WEEKLY LOCALIZATION FILMS AND DETECTION OF FIELD PLACEMENT ERRORS [J].
BYHARDT, RW ;
COX, JD ;
HORNBURG, A ;
LIERMANN, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1978, 4 (9-10) :881-887
[6]   EVALUATION OF CHANGES IN THE LOCATION AND SHAPE OF THE PROSTATE AND RECTUM DURING A 7 WEEK COURSE OF CONFORMAL RADIOTHERAPY [J].
FORMAN, JD ;
MESINA, CF ;
HE, T ;
DEVI, SB ;
BENJOSEF, E ;
PELIZZARI, C ;
VIJAYAKUMAR ;
CHEN, GT .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 :222-222
[7]   A METHOD TO ANALYZE 2-DIMENSIONAL DAILY RADIOTHERAPY PORTAL IMAGES FROM AN ONLINE FIBEROPTIC IMAGING-SYSTEM [J].
GRAHAM, ML ;
CHENG, AY ;
GEER, LY ;
BINNS, WR ;
VANNIER, MW ;
WONG, JW .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (03) :613-619
[8]   STUDY OF TREATMENT VARIATION IN THE RADIOTHERAPY OF HEAD AND NECK TUMORS USING A FIBEROPTIC ONLINE RADIOTHERAPY IMAGING-SYSTEM [J].
HALVERSON, KJ ;
LEUNG, TC ;
PELLET, JB ;
GERBER, RL ;
WEINHOUS, MS ;
WONG, JW .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (05) :1327-1336
[9]   PATTERNS OF CARE AND RTOG STUDIES IN PROSTATE-CANCER - LONG-TERM SURVIVAL, HAZARD RATE OBSERVATIONS, AND POSSIBILITIES OF CURE [J].
HANKS, GE ;
KRALL, JM ;
HANLON, AL ;
ASBELL, SO ;
PILEPICH, MV ;
OWEN, JB .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (01) :39-45
[10]   PSA CONFIRMATION OF CURE AT 10 YEARS OF T-1B, T-2, N-0, M(0) PROSTATE-CANCER PATIENTS TREATED IN RTOG PROTOCOL-7706 WITH EXTERNAL-BEAM IRRADIATION [J].
HANKS, GE ;
PEREZ, CA ;
KOZAR, M ;
ASBELL, SO ;
PILEPICH, MV ;
PAJAK, TF .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 30 (02) :289-292