Three-way partial least-squares regression for the simultaneous kinetic-enzymatic determination of xanthine and hypoxanthine in human urine

被引:39
作者
Amigo, JM [1 ]
Coello, J [1 ]
Maspoch, S [1 ]
机构
[1] Univ Autonoma Barcelona, Barcelona 08193, Spain
关键词
oxipurines; urine analysis; three-way principal component analysis; three-way partial least-squares regression; simultaneous kinetic determination;
D O I
10.1007/s00216-005-3275-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The performance of three-way principal component analysis and three-way partial least-squares regression when applied to a complex kinetic-enzymatic system is studied, in order to investigate the analytical potential of the combined use of these chemometric technologies for non-selective enzymatic systems. A enzymatic-kinetic procedure for the simultaneous determination of hypoxanthine and xanthine in spiked samples of human urine is proposed. The chemical system involves two consecutive reactions catalyzed by xanthine oxidase (EC 1.17.3.2). This enzyme catalyzes the oxidation of hypoxanthine, first to xanthine and then to uric acid, a competitive inhibitor of the reactions. The influence of uric acid during quantitative determination was considered in the design of the calibration set. The sample and enzyme solution were mixed in a stopped-flow module and the reaction was monitored using a diode array spectrophotometer. The recorded data have an intrinsical three-component structure (samples, time and wavelength). This data array was studied via three-way principal component analysis and was modeled for quantitative purposes using a three-way partial least-squares calibration procedure. Results are compared with those obtained by applying classical bilinear PLS to the previously unfolded data matrix.
引用
收藏
页码:1380 / 1388
页数:9
相关论文
共 32 条
  • [1] [Anonymous], 1990, Journal ofChemometrics, DOI DOI 10.1002/CEM.1180040105
  • [2] Simultaneous enzymatic spectrophotometric determination of ethanol and methanol by use of artificial neural networks for calibration
    Blanco, M
    Coello, J
    Iturriaga, H
    Maspoch, S
    Porcel, M
    [J]. ANALYTICA CHIMICA ACTA, 1999, 398 (01) : 83 - 92
  • [3] Review of chemometrics applied to spectroscopy: 1985-95 .3. Multi-way analysis
    Bro, R
    Workman, JJ
    Mobley, PR
    Kowalski, BR
    [J]. APPLIED SPECTROSCOPY REVIEWS, 1997, 32 (03) : 237 - 261
  • [4] Bro R, 1996, J CHEMOMETR, V10, P47, DOI 10.1002/(SICI)1099-128X(199601)10:1<47::AID-CEM400>3.0.CO
  • [5] 2-C
  • [6] Development of a system with enzyme reactors for the determination of fish freshness
    Carsol, MA
    Mascini, M
    [J]. TALANTA, 1998, 47 (02) : 335 - 342
  • [7] Separation of six purine bases by capillary electrophoresis with electrochemical detection
    Chen, G
    Chu, QC
    Zhang, LY
    Ye, JN
    [J]. ANALYTICA CHIMICA ACTA, 2002, 457 (02) : 225 - 233
  • [8] Simultaneous kinetic-spectrophotometric determination of levodopa and benserazide by bi- and three-way partial least squares calibration
    Coello, J
    Maspoch, S
    Villegas, N
    [J]. TALANTA, 2000, 53 (03) : 627 - 637
  • [9] Evaluation of classical and three-way multivariate calibration procedures in kinetic-spectrophotometric analysis
    Crouch, SR
    Coello, J
    Maspoch, S
    Porcel, M
    [J]. ANALYTICA CHIMICA ACTA, 2000, 424 (01) : 115 - 126
  • [10] Simultaneous measurement of allantoin, uric acid, xanthine and hypoxanthine in blood by high-performance liquid chromatography
    Czauderna, M
    Kowalczyk, J
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1997, 704 (1-2): : 89 - 98