Evaluation of classical and three-way multivariate calibration procedures in kinetic-spectrophotometric analysis

被引:32
作者
Crouch, SR
Coello, J
Maspoch, S [1 ]
Porcel, M
机构
[1] Univ Autonoma Barcelona, Fac Ciencias, Unidad Quim Analit, Dept Quim, E-08193 Barcelona, Spain
[2] Michigan State Univ, Dept Chem, E Lansing, MI 48824 USA
关键词
simultaneous kinetic determination; multivariate calibration; N-way methods; 4-(2-pyridylazo)resorcinol; metal ions determination; stopped-flow photodiode array spectrophotometry;
D O I
10.1016/S0003-2670(00)01108-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The bidimensional multivariate regression procedures: multiple linear regression (MLR), principal component regression (PCR), partial least squares regression (PLS) and continuum regression (CR), and several N-way methods such as N-way PLS (nPLS) and parallel factor analysis (PARAFAC) are tested as calibration methods for the kinetic-spectrophotometric determination of ternary mixtures in a pseudo first-order kinetic system. The different calibration procedures were first applied to computer simulated kinetic-spectrophotometric data where the effect of spectral overlap and the differences in the kinetic constants were evaluated at a low level of experimental noise. Later they were applied to the stopped-flow kinetic-spectrophotometric simultaneous resolution of Co(II), Ni(II) and Ga(III) using 4-(2-pyridylazo)resorcinol (PAR) as a chromogenic reagent. Accurate estimations of concentrations with relative standard errors of prediction of about 8% were obtained even though a high degree of spectral overlap and similar rate constants were present. The study of the influence of experimental noise on the 3-component system justifies the difference between the simulations and the experimental results for the different calibration procedures. PARAFAC and MLR did not allow the resolution of the proposed 3-component system. CR provided slightly better results than those obtained by PLS, PCR and nPLS. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:115 / 126
页数:12
相关论文
共 28 条
[1]   SIMULTANEOUS STOPPED-FLOW KINETIC DETERMINATION OF GALLIUM AND INDIUM BY A LIGAND SUBSTITUTION-REACTION [J].
ABOLLINO, O ;
MENTASTI, E ;
SARZANINI, C ;
PORTA, V ;
KIRSCHENBAUM, LJ .
ANALYST, 1991, 116 (11) :1167-1170
[2]   Novel application and comparison of multivariate calibration for the simultaneous determination of Cu, Zn and Mn at trace levels using flow injection diode array spectrophotometry [J].
Azubel, M ;
Fernández, FM ;
Tudino, MB ;
Troccoli, OE .
ANALYTICA CHIMICA ACTA, 1999, 398 (01) :93-102
[3]  
1998, HDB CHEMOMETRICS QUA, V11, P310
[4]   AUTOMATED STOPPED-FLOW SPECTROPHOTOMETER WITH DIGITAL SEQUENCING FOR MILLISECOND ANALYSES [J].
BECKWITH, PM ;
CROUCH, SR .
ANALYTICAL CHEMISTRY, 1972, 44 (02) :221-&
[5]   Simultaneous enzymatic spectrophotometric determination of ethanol and methanol by use of artificial neural networks for calibration [J].
Blanco, M ;
Coello, J ;
Iturriaga, H ;
Maspoch, S ;
Porcel, M .
ANALYTICA CHIMICA ACTA, 1999, 398 (01) :83-92
[6]   KINETIC SPECTROPHOTOMETRIC METHOD FOR ANALYZING MIXTURES OF METAL-IONS BY STOPPED-FLOW INJECTION-ANALYSIS USING PARTIAL LEAST-SQUARES REGRESSION [J].
BLANCO, M ;
COELLO, J ;
ITURRIAGA, H ;
MASPOCH, S ;
RIBA, J .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :2905-2911
[7]   KINETIC SPECTROPHOTOMETRIC DETERMINATION OF GA(III)-AL(III) MIXTURES BY STOPPED-FLOW INJECTION-ANALYSIS USING PRINCIPAL COMPONENT REGRESSION [J].
BLANCO, M ;
COELLO, J ;
ITURRIAGA, H ;
MASPOCH, S ;
RIBA, J ;
ROVIRA, E .
TALANTA, 1993, 40 (02) :261-267
[8]   ARTIFICIAL NEURAL NETWORKS FOR MULTICOMPONENT KINETIC DETERMINATIONS [J].
BLANCO, M ;
COELLO, J ;
ITURRIAGA, H ;
MASPOCH, S ;
REDON, M .
ANALYTICAL CHEMISTRY, 1995, 67 (24) :4477-4483
[9]   PARTIAL LEAST-SQUARES REGRESSION FOR MULTICOMPONENT KINETIC DETERMINATIONS IN LINEAR AND NONLINEAR-SYSTEMS [J].
BLANCO, M ;
COELLO, J ;
ITURRIAGA, H ;
MASPOCH, S ;
REDON, M .
ANALYTICA CHIMICA ACTA, 1995, 303 (2-3) :309-320
[10]   Artificial neural networks and partial least squares regression for pseudo-first-order with respect to the reagent multicomponent kinetic-spectrophotometric determinations [J].
Blanco, M ;
Coello, J ;
Iturriaga, H ;
Maspoch, S ;
Redon, M ;
Villegas, N .
ANALYST, 1996, 121 (04) :395-400