Evaluation of classical and three-way multivariate calibration procedures in kinetic-spectrophotometric analysis

被引:32
作者
Crouch, SR
Coello, J
Maspoch, S [1 ]
Porcel, M
机构
[1] Univ Autonoma Barcelona, Fac Ciencias, Unidad Quim Analit, Dept Quim, E-08193 Barcelona, Spain
[2] Michigan State Univ, Dept Chem, E Lansing, MI 48824 USA
关键词
simultaneous kinetic determination; multivariate calibration; N-way methods; 4-(2-pyridylazo)resorcinol; metal ions determination; stopped-flow photodiode array spectrophotometry;
D O I
10.1016/S0003-2670(00)01108-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The bidimensional multivariate regression procedures: multiple linear regression (MLR), principal component regression (PCR), partial least squares regression (PLS) and continuum regression (CR), and several N-way methods such as N-way PLS (nPLS) and parallel factor analysis (PARAFAC) are tested as calibration methods for the kinetic-spectrophotometric determination of ternary mixtures in a pseudo first-order kinetic system. The different calibration procedures were first applied to computer simulated kinetic-spectrophotometric data where the effect of spectral overlap and the differences in the kinetic constants were evaluated at a low level of experimental noise. Later they were applied to the stopped-flow kinetic-spectrophotometric simultaneous resolution of Co(II), Ni(II) and Ga(III) using 4-(2-pyridylazo)resorcinol (PAR) as a chromogenic reagent. Accurate estimations of concentrations with relative standard errors of prediction of about 8% were obtained even though a high degree of spectral overlap and similar rate constants were present. The study of the influence of experimental noise on the 3-component system justifies the difference between the simulations and the experimental results for the different calibration procedures. PARAFAC and MLR did not allow the resolution of the proposed 3-component system. CR provided slightly better results than those obtained by PLS, PCR and nPLS. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:115 / 126
页数:12
相关论文
共 28 条
[11]  
BLANCO M, 1999, 9AS JORNADES ANAL IN
[12]  
Bro R, 1996, J CHEMOMETR, V10, P47, DOI 10.1002/(SICI)1099-128X(199601)10:1<47::AID-CEM400>3.3.CO
[13]  
2-3
[14]   RESOLUTION OF SIMULTANEOUS KINETIC SPECTROPHOTOMETRIC PROCESSES BY FACTOR-ANALYSIS [J].
CLADERA, A ;
GOMEZ, E ;
ESTELA, JM ;
CERDA, V .
ANALYTICAL CHEMISTRY, 1993, 65 (06) :707-715
[15]  
Crouch SR, 1998, ANAL CHEM, V70, p53R
[16]   Factors affecting the accuracy of multicomponent kinetic-spectrophotometric determinations based on multivariate calibration methods [J].
Cullen, TF ;
Crouch, SR .
ANALYTICA CHIMICA ACTA, 2000, 407 (1-2) :135-146
[17]   Multicomponent kinetic determinations using multivariate calibration techniques [J].
Cullen, TF ;
Crouch, SR .
MIKROCHIMICA ACTA, 1997, 126 (1-2) :1-9
[18]  
CULLEN TF, 1999, THESIS MICHIGAN STAT
[19]   Parafac decomposition of three-way kinetic-spectrophotometric spectral matrices corresponding to mixtures of heavy metal ions [J].
da Silva, JCGE ;
Oliveira, CJS .
TALANTA, 1999, 49 (04) :889-897
[20]  
Izquierdo A, 1998, QUIM ANAL, V17, P67