Enhancing chemi-mechanical transduction in microcantilever chemical sensing by surface modification

被引:42
作者
Headrick, JJ
Sepaniak, MJ
Lavrik, NV
Datskos, PG
机构
[1] Oak Ridge Natl Lab, Oak Ridge, TN 37831 USA
[2] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
关键词
microcantilevers; selective coatings; surface modification; chemical sensors;
D O I
10.1016/S0304-3991(03)00069-X
中图分类号
TH742 [显微镜];
学科分类号
摘要
The use of chemically selective thin-film coatings has been shown to enhance both the chemical selectivity and sensitivity of microcantilever (MC) chemical sensors. As an analyte absorbs into the coating, the coating can swell or contract causing an in-plane stress at the associated MC surface. However, much of the stress upon absorption of an analyte may be lost through slippage of the chemical coatings on the MC surface, or through relaxation of the coating in a manner that minimizes stress to the cantilever. Structural modificatibn of MC chemical sensors can improve the stress transduction between,the chemical coating and the MC. Surfaces of silicon MC were modified with focused ion beam milling. Sub-micron channels were milled across the width of the MC. Responses of the nanostructured, coated MCs to 2,3-dihydroxynaphthalene and a series of volatile organic compounds (VOCs) were compared to smooth, coated MCs. The analytical figures of merit for the nanostructured, coated MCs in the sensing of VOCs were found to be better than the unstructured MCs. A comparison is made with a previously reported method of creating disordered nanostructured MC surfaces. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:417 / 424
页数:8
相关论文
共 37 条
[1]   A cantilever array-based artificial nose [J].
Baller, MK ;
Lang, HP ;
Fritz, J ;
Gerber, C ;
Gimzewski, JK ;
Drechsler, U ;
Rothuizen, H ;
Despont, M ;
Vettiger, P ;
Battiston, FM ;
Ramseyer, JP ;
Fornaro, P ;
Meyer, E ;
Güntherodt, HJ .
ULTRAMICROSCOPY, 2000, 82 (1-4) :1-9
[2]   Surface stress in the self-assembly of alkanethiols on gold [J].
Berger, R ;
Delamarche, E ;
Lang, HP ;
Gerber, C ;
Gimzewski, JK ;
Meyer, E ;
Guntherodt, HJ .
SCIENCE, 1997, 276 (5321) :2021-2024
[3]   Selectivity of chemical sensors based on micro-cantilevers coated with thin polymer films [J].
Betts, TA ;
Tipple, CA ;
Sepaniak, MJ ;
Datskos, PG .
ANALYTICA CHIMICA ACTA, 2000, 422 (01) :89-99
[4]   Environmental sensors based on micromachined cantilevers with integrated read-out [J].
Boisen, A ;
Thaysen, J ;
Jensenius, H ;
Hansen, O .
ULTRAMICROSCOPY, 2000, 82 (1-4) :11-16
[5]   Multiple-input microcantilever sensors [J].
Britton, CL ;
Jones, RL ;
Oden, PI ;
Hu, Z ;
Warmack, RJ ;
Smith, SF ;
Bryan, WL ;
Rochelle, JM .
ULTRAMICROSCOPY, 2000, 82 (1-4) :17-21
[6]   MECHANISMS OF ENANTIOMERIC RESOLUTION IN CYCLODEXTRIN-MODIFIED CAPILLARY ELECTROPHORETIC SEPARATIONS OF BINAPHTHYL COMPOUNDS [J].
COPPER, CL ;
DAVIS, JB ;
SEPANIAK, MJ .
CHIRALITY, 1995, 7 (06) :401-408
[7]   SEPARATIONS OF DERIVATIZED AMINO-ACID ENANTIOMERS BY CYCLODEXTRIN-MODIFIED CAPILLARY ELECTROPHORESIS - MECHANISTIC AND MOLECULAR MODELING STUDIES [J].
COPPER, CL ;
DAVIS, JB ;
COLE, RO ;
SEPANIAK, MJ .
ELECTROPHORESIS, 1994, 15 (06) :785-792
[8]   Selectivity in capillary electrochromatography using native and single isomer anionic cyclodextrin reagents [J].
Culha, M ;
Fox, S ;
Sepaniak, M .
ANALYTICAL CHEMISTRY, 2000, 72 (01) :88-95
[9]  
CULHA M, 2002, THESIS U TENNESSEE K
[10]   Detection of 2-mercaptoethanol using gold-coated micromachined cantilevers [J].
Datskos, PG ;
Sauers, I .