We present a study that helped optimize a three-dimensional isotropic contrast-enhanced MR angiographic (CE-MRA) technique, using sensitivity encoding ( SENSE) and random elliptic centric k-space filling. Two-dimensional gradient-echo sequence (TR/TE/flip angle 3.4/0.97/40 degrees) was used to generate time - intensity curves in porcine carotid arteries for a fixed dose of Gd-DTPA (0.02 mmol/kg) at the following intravenous injection rates: 0.1, 0.3, 0.5, 1.0, 1.5, 2.0, and 3.0 ml/s. The time of contrast arrival and time to peak were recorded. Based on the time - intensity curves, three-dimensional high-resolution isotropic ( 1 mm(3)) CE-MRA sequence (TR/TE/flip angle: 4.9/2.4/ 30 degrees), using SENSE ( reduction factor of 2) and random elliptic centric k-space filling, was initiated twice for each of the above injection rates: first at the time of contrast arrival and second at the time of peak contrast. The three-dimensional CE-MRA images were analyzed for artifacts, signal-to-noise ratio, and venous contamination. For the three-dimensional CE-MRA acquisitions that were initiated at the time of contrast arrival, there was a gradual improvement in signal-to-noise ratio (SNR) in the carotid arteries with increasing injection rate. The same trend was not observed for the acquisitions that were initiated at the time of peak contrast. SENSE combined with random elliptic k-space acquisition in CE-MRA allows for higher SNR with fewer ringing artifacts at faster contrast injection rates.
引用
收藏
页码:668 / 673
页数:6
相关论文
共 11 条
[1]   The effect of injection rate on time-resolved contrast-enhanced peripheral MRA [J].
Carroll, TJ ;
Korosec, FR ;
Swan, JS ;
Hany, TF ;
Grist, TM ;
Mistretta, CA .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (04) :401-410
[2]  
Golay X, 2001, AM J NEURORADIOL, V22, P1615
[3]  
Pruessmann KP, 1999, MAGNET RESON MED, V42, P952, DOI 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO
[4]  
2-S
[5]   Optimal dose of Gd-DTPA in dynamic MR studies [J].
Rusinek, H ;
Lee, VS ;
Johnson, G .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (02) :312-316
[6]  
Svensson J, 1999, J MAGN RESON IMAGING, V10, P919, DOI 10.1002/(SICI)1522-2586(199912)10:6<919::AID-JMRI3>3.3.CO
[7]  
2-N
[8]  
Weiger M, 2000, J MAGN RESON IMAGING, V12, P671, DOI 10.1002/1522-2586(200011)12:5<671::AID-JMRI3>3.0.CO
[9]  
2-F
[10]   Randomly segmented central k-space ordering in high-spatial-resolution contrast-enhanced MR angiography of the supraaortic arteries: Initial experience [J].
Willinek, WA ;
Gieseke, J ;
Conrad, R ;
Strunk, H ;
Hoogeveen, R ;
von Falkenhausen, M ;
Keller, E ;
Urbach, H ;
Kuhl, CK ;
Schild, HH .
RADIOLOGY, 2002, 225 (02) :583-588