Acute and long-term outcomes of cutting balloon angioplasty followed by gamma brachytherapy for in-stent restenosis

被引:10
作者
Kobayashi, Y
Mehran, R
Mintz, GS
Dangas, G
Moussa, I
Collins, M
Brara, P
Moussavian, M
Lansky, AJ
Stone, GW
Leon, MB
Moses, JW
Teirstein, PS
机构
[1] Lenox Hill Heart & Vasc Inst, Cardiovasc Res Fdn, New York, NY 10022 USA
[2] Scripps Res Inst, Div Cardiovasc Dis, La Jolla, CA USA
关键词
D O I
10.1016/j.amjcard.2003.08.018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In-stent restenosis lesions were divided into 2 groups according to the use of cutting balloon (n = 76) or conventional balloon angioplasty (n = 407) before gamma-brachytherapy. Cutting balloon angioplasty, compared with conventional balloon angioplasty, in patients undergoing gamma-brachytherapy for in-stent restenosis is associated with less requirement for new stents (11% vs 22%, p = 0.02) but similar target vessel revascularization (35.1% vs 29.8%, p = 0.4) at follow-up. (C) 2003 by Excerpta Medica, Inc.
引用
收藏
页码:1329 / 1331
页数:3
相关论文
共 10 条
[1]   Cutting balloon angioplasty for the treatment of in-stent restenosis: A matched comparison with rotational atherectomy, additional stent implantation and balloon angioplasty [J].
Adamian, M ;
Colombo, A ;
Briguori, C ;
Nishida, T ;
Marsico, F ;
Di Mario, C ;
Albiero, R ;
Moussa, I ;
Moses, JW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (03) :672-679
[2]  
Ahmed JM, 2001, CIRCULATION, V103, P188
[3]  
Ajani A E, 2001, J Invasive Cardiol, V13, P554
[4]  
Chen SL, 2002, CHINESE MED J-PEKING, V115, P166
[5]   Localized intracoronary gamma-radiation therapy to inhibit the recurrence of restenosis after stenting. [J].
Leon, MB ;
Teirstein, PS ;
Moses, JW ;
Tripuraneni, P ;
Lansky, AJ ;
Jani, S ;
Wong, SC ;
Fish, D ;
Ellis, S ;
Holmes, DR ;
Kerieakes, D ;
Kuntz, RE .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 344 (04) :250-256
[6]   Late vascular response to repeat stenting for in-stent restenosis with and without radiation - An intravascular ultrasound volumetric analysis [J].
Morino, Y ;
Limpijankit, T ;
Honda, Y ;
Lansky, AJ ;
Waksman, R ;
Bonneau, HN ;
Yock, PG ;
Mintz, GS ;
Fitzgerald, PJ .
CIRCULATION, 2002, 105 (21) :2465-2468
[7]  
Muramatsu T, 2001, J Invasive Cardiol, V13, P439
[8]   Geographic miss -: A cause of treatment failure in radio-oncology applied to intracoronary radiation therapy [J].
Sabaté, M ;
Costa, MA ;
Kozuma, K ;
Kay, IP ;
van der Giessen, WJ ;
Coen, VLMA ;
Ligthart, JMR ;
Serrano, P ;
Levendag, PC ;
Serruys, PW .
CIRCULATION, 2000, 101 (21) :2467-2471
[9]   Catheter-based radiotherapy to inhibit restenosis after coronary stenting [J].
Teirstein, PS ;
Massullo, V ;
Jani, S ;
Popma, JJ ;
Mintz, GS ;
Russo, RJ ;
Schatz, RA ;
Guarneri, EM ;
Steuterman, S ;
Morris, NB ;
Leon, MB ;
Tripuraneni, P .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (24) :1697-1703
[10]   Intracoronary γ-radiation therapy after angioplasty inhibits recurrence in patients with in-stent restenosis [J].
Waksman, R ;
White, L ;
Chan, RC ;
Bass, BG ;
Geirlach, L ;
Mintz, GS ;
Satler, LF ;
Mehran, R ;
Serruys, PW ;
Lansky, AJ ;
Fitzgerald, P ;
Bhargava, B ;
Kent, KM ;
Pichard, AD ;
Leon, MB .
CIRCULATION, 2000, 101 (18) :2165-2171