Receiver-operating characteristic (ROC) curves: A fundamental tool for improving the clinical usefulness of in vitro IgE tests

被引:17
作者
Plebani, M
Borghesan, F
Basso, D
Faggian, D
机构
[1] UNIV HOSP,CENT LAB,DEPT LAB MED,PADUA,ITALY
[2] CTR BIOMED RES,CASTELFRANCO VENE,ITALY
关键词
allergen-specific IgE; inhalant allergies; receiver-operating characteristic (ROC) curves; skin prick test;
D O I
10.1111/j.1398-9995.1996.tb04638.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
In order to establish the most efficient thresholds for serum allergen-specific IgE measured by the Pharmacia CAP System, a ''second-generation'' in vitro method, we evaluated results from 89 subjects with suspected inhalant allergies, using receiver-operating characteristic (ROC) curve analysis. Sera samples were analyzed by the Pharmacia CAP System for specific IgE, the choice of allergens to be tested being based upon the symptoms and clinical history of each patient. Results were analyzed by ROC analysis for the five most representative allergens, cat dander (e(1)), Dermatophagoides pteronyssinus (d(1)), Lolium perenne (g(5)), wall pellitory (W-19), and wormwood (w(5)). The areas under the ROC curves were found to be satisfactory, ranging from 0.931 (e(1)) to 0.974 (g(5)) when we excluded w(5), which had a significantly smaller area (0.81). To establish the most efficient threshold for each allergen, we calculated the clinical sensitivity, specificity, efficiency, and negative and positive predictive values. The thresholds giving a higher diagnostic efficiency were as follows: 0.40 kUa/l for d(1), 0.55 kUa/l for g(5), 0.50 for e(1), 0.65 kUa/l for w(19), and 1.00 kUa/l for w(5). It is concluded that quantitative reporting of specific IgE measurement has numerous advantages, but the choice of the positive threshold seems to be a prerequisite for obtaining the optimal clinical efficiency. It is also suggested that a specific threshold should be adopted for each allergen.
引用
收藏
页码:407 / 411
页数:5
相关论文
共 16 条
[1]   COMPARISON BETWEEN RAST AND PHARMACIA CAP SYSTEM - A NEW AUTOMATED SPECIFIC IGE ASSAY [J].
BOUSQUET, J ;
CHANEZ, P ;
CHANAL, I ;
MICHEL, FB .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1990, 85 (06) :1039-1043
[2]   RECEIVER OPERATING CHARACTERISTIC ANALYSIS - A USEFUL METHOD FOR A COMPARISON OF THE CLINICAL RELEVANCE OF 2 IN-VITRO IGE TESTS [J].
DEBLAY, F ;
ZANA, H ;
OFFNER, M ;
VEROT, A ;
VELTEN, M ;
PAULI, G .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1993, 92 (02) :255-263
[3]   EVALUATION OF A CAPSULATED HYDROPHILIC CARRIER POLYMER (THE IMMUNOCAP) FOR MEASUREMENT OF SPECIFIC IGE ANTIBODIES [J].
EWAN, PW ;
COOTE, D .
ALLERGY, 1990, 45 (01) :22-29
[4]  
Galen RS, 1975, NORMALITY PREDICTIVE
[5]  
GERHARDT W, 1986, SCAND J CLIN LAB I S, V181, P1
[6]  
HANLEY JA, 1989, CRIT REV DIAGN IMAG, V29, P307
[7]   SOFTWARE FOR ILLUSTRATIVE PRESENTATION OF BASIC CLINICAL CHARACTERISTICS OF LABORATORY TESTS - GRAPHROC FOR WINDOWS [J].
KAIRISTO, V ;
POOLA, A .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1995, 55 :43-60
[8]   COMPARISON BETWEEN MAGIC LITE(R)-SYSTEM AND CAP(R)-SYSTEM - 2 AUTOMATED SPECIFIC IGE ANTIBODY-ASSAYS [J].
KLEINETEBBE, J ;
EICKHOLT, M ;
GATJEN, M ;
BRUNNEE, T ;
OCONNOR, A ;
KUNKEL, G .
CLINICAL AND EXPERIMENTAL ALLERGY, 1992, 22 (04) :475-484
[9]   CLINICAL-EVALUATION OF A NEW INVITRO ASSAY FOR SPECIFIC IGE, THE IMMUNO CAP SYSTEM [J].
LEIMGRUBER, A ;
MOSIMANN, B ;
CLAEYS, M ;
SEPPEY, M ;
JACCARD, Y ;
AUBERT, V ;
PEITREQUIN, R ;
NISOLI, MP ;
PECOUD, A .
CLINICAL AND EXPERIMENTAL ALLERGY, 1991, 21 (01) :127-131
[10]  
PLEBANI M, 1995, ANN ALLERG ASTHMA IM, V74, P23