Comparison real-time and intermittent triggered myocardial contrast echocardiography for quantification coronary stenosis severity and transmural perfusion gradient

被引:50
作者
Masugata, H [1 ]
Lafitte, S [1 ]
Peters, B [1 ]
Strachan, GM [1 ]
DeMaria, AN [1 ]
机构
[1] Univ Calif San Diego, Med Ctr, Div Cardiovasc, San Diego, CA 92103 USA
关键词
echocardiography; perfusion; blood flow;
D O I
10.1161/hc3801.095694
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Both intermittent triggered and real-time myocardial contrast echocardiography (MCE) have been proposed to detect impaired myocardial perfusion. We compared the ability of these 2 methods to quantify altered myocardial blood flow (MBF) and transmural distribution of MBF produced by graded coronary stenoses. Methods and Results-In 8 open-chest dogs, we created 4 graded left anterior descending coronary artery (LAD) stenoses: 3 levels of reduced adenosine hyperemia (non-flow-limiting at rest) and 1 grade of flow-limiting at rest. Real-time MCE was performed with SonoVue infusion using low-energy power pulse inversion (ATL) imaging, whereas ECG-gated intermittent triggered imaging used high energy at pulsing intervals from 1:1 to 1:10. LAD signal intensity (SI) was plotted versus time by real-time MCE and versus pulsing intervals by triggered MCE and was fitted to a 1-exponential function to obtain plateau SI (A) and the rate of SI rise (b). Visual detection of decreased opacification was equivalent by triggered and real-time MCE. Fluorescent microsphere-derived MBF ratio in LAD/left circumflex artery beds demonstrated close correlation with both real-time imaging (b, r=0.79; AXb, r=0.81) and triggered imaging (b, r=0.78; AXb, r=0.80). The endocardial/epicardial ratio of MBF in the LAD bed demonstrated closer correlation with the endocardial/epicardial ratios of b (r=0.71) and AXb (r=0.67) obtained by real-time than triggered imaging (b, r=0.42; AXb, r=0.52). Conclusions-Real-time and triggered MCE are equivalent in their ability to identify coronary stenosis and quantify altered MBF.
引用
收藏
页码:1550 / 1556
页数:7
相关论文
共 8 条
[1]   VALIDATION OF FLUORESCENT-LABELED MICROSPHERES FOR MEASUREMENT OF REGIONAL ORGAN PERFUSION [J].
GLENNY, RW ;
BERNARD, S ;
BRINKLEY, M .
JOURNAL OF APPLIED PHYSIOLOGY, 1993, 74 (05) :2585-2597
[2]   Assessment of transmural distribution of myocardial perfusion with contrast echocardiography [J].
Linka, AZ ;
Sklenar, J ;
Wei, K ;
Jayaweera, AR ;
Skyba, DM ;
Kaul, S .
CIRCULATION, 1998, 98 (18) :1912-1920
[3]   Clinical applications of transpulmonary contrast echocardiography [J].
Main, ML ;
Grayburn, PA .
AMERICAN HEART JOURNAL, 1999, 137 (01) :144-153
[4]   Assessment of coronary stenosis severity and transmural perfusion gradient by myocardial contrast echocardiography - Comparison of gray-scale B-mode with power Doppler imaging [J].
Masugata, H ;
Cotter, B ;
Peters, B ;
Ohmori, K ;
Mizushige, K ;
DeMaria, AN .
CIRCULATION, 2000, 102 (12) :1427-1433
[5]   Real-time visualization of myocardial perfusion and wall thickening in human beings with intravenous ultrasonographic contrast and accelerated intermittent harmonic imaging [J].
Porter, TR ;
Li, SP ;
Jiang, L ;
Grayburn, P ;
Deligonul, U .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (04) :266-271
[6]   TRANSIENT MYOCARDIAL CONTRAST AFTER INITIAL EXPOSURE TO DIAGNOSTIC ULTRASOUND PRESSURES WITH MINUTE DOSES OF INTRAVENOUSLY INJECTED MICROBUBBLES - DEMONSTRATION AND POTENTIAL MECHANISMS [J].
PORTER, TR ;
XIE, F .
CIRCULATION, 1995, 92 (09) :2391-2395
[7]   Real-time contrast echo assessment of myocardial perfusion at low emission power:: First experimental and clinical results using power pulse inversion imaging [J].
Tiemann, K ;
Lohmeier, S ;
Kuntz, S ;
Köster, J ;
Pohl, C ;
Burns, P ;
Porter, TR ;
Nanda, NC ;
Lüderitz, B ;
Becher, H .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1999, 16 (08) :799-809
[8]  
Wei K, 1998, CIRCULATION, V97, P473