Partial discharge diagnostics and electrical equipment insulation condition assessment

被引:271
作者
Stone, GC [1 ]
机构
[1] Iris Power Engn, Unit 2, Toronto, ON M9C 1B2, Canada
关键词
D O I
10.1109/TDEI.2005.1522184
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Partial discharge (PD) measurement has long been used as a test to evaluate different insulation system designs, and as a quality control test for new equipment. However, in the past 20 years, PD measurement has been widely applied to diagnose the condition of the electrical insulation in operating apparatus such as switchgear, transformers, cables, as well as motor and generator stator windings. Improvements in the capabilities as well the lower cost of sensors, electronics and memory is partly the reason for the increased popularity of PD diagnostics. Another reason has been the development of methods - including the use of ultrawide band detection - to improve the reliability of the PD measurement in the presence of noise. In addition, rapid progress is being made in automated pattern recognition techniques that also helps to suppress noise. This paper reviews the various PD measurement technologies that have been specifically developed to improve PD diagnostic methods, and outlines how they have been implemented for stators, cables, transformers and switchgear. Areas for further research are also presented.
引用
收藏
页码:891 / 904
页数:14
相关论文
共 50 条
[31]   Continuous on-line partial discharge monitoring of generator stator windings [J].
Lloyd, BA ;
Campbell, SR ;
Stone, GC .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1999, 14 (04) :1131-1137
[32]   Interpretation of wavelet analysis and its application in partial discharge detection [J].
Ma, X ;
Zhou, C ;
Kemp, IJ .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2002, 9 (03) :446-457
[33]  
MARSH T, 2001, REAL TIME ASSESSED C
[34]   EVALUATION OF FIELD AGED CROSS-LINKED POLYETHYLENE CABLES BY PARTIAL DISCHARGE LOCATION [J].
MASHIKIAN, MS ;
LUTHER, R ;
MCIVER, JC ;
JURCISIN, J ;
SPENCER, PW .
IEEE TRANSACTIONS ON POWER DELIVERY, 1994, 9 (02) :620-628
[35]   ASSESSMENT OF DIELECTRIC DEGRADATION BY ULTRAWIDE-BAND PD DETECTION [J].
MORSHUIS, P .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1995, 2 (05) :744-760
[36]   NOVEL PARTIAL DISCHARGE MEASUREMENT COMPUTER-AIDED MEASUREMENT SYSTEMS [J].
OKAMOTO, T ;
TANAKA, T .
IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1986, 21 (06) :1015-1019
[37]  
RIZZETTO S, 1987, IEEE PUBLICATION, P89
[38]   Fuzzy logic applied to PD pattern classification [J].
Salama, MMA ;
Bartnikas, R .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2000, 7 (01) :118-123
[39]   Determination of neural-network topology for partial discharge pulse pattern recognition [J].
Salama, MMA ;
Bartnikas, R .
IEEE TRANSACTIONS ON NEURAL NETWORKS, 2002, 13 (02) :446-456
[40]   CAN FRACTAL FEATURES BE USED FOR RECOGNIZING 3-D PARTIAL DISCHARGE PATTERNS [J].
SATISH, L ;
ZAENGL, WS .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1995, 2 (03) :352-359