Construction of a novel peptide nucleic acid piezoelectric gene sensor microarray detection system

被引:22
作者
Chen, M
Liu, MH
Yu, LL
Cai, GR
Chen, QH
Wu, R
Wang, F
Zhang, B
Jiang, TL
Fu, WL [1 ]
机构
[1] Third Mil Med Univ, SW Hosp, Dept Lab Diag, Chongqing 400038, Peoples R China
[2] Third Mil Med Univ, Daping Hosp, Dept Gynecol & Obstet, Chongqing 400042, Peoples R China
[3] Chinese Elect Sci & Tech Grp Co, Res Inst 26, Chongqing 400060, Peoples R China
关键词
peptide nucleic acid; gene sensor; microarray; HBV;
D O I
10.1166/jnn.2005.223
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A novel 2 x 5 clamped style piezoelectric gene sensor microarray has been successfully constructed. Every crystal unit of the fabricated gene sensor can oscillate independently without interfering with each other. The bis-peptide nucleic acid (bis-PNA) probe, which can combine with target DNA or RNA sequences more effectively and specifically than a DNA probe, was designed and immobilized on the surface of the gene sensor microarray to substitute the conventional DNA probe for direct detection of the hepatitis B virus (HBV) genomic DNA. Detection conditions were then explored and optimized. Results showed that PBS buffer of pH 6.8, an ion concentration of 20 mmol/liter, and a probe concentration of 1.5 mu mol/liter were optimal for the detection system. Under such optimized experimental conditions, the specificity of bis-PNA was proved much higher than that of DNA probe. The relationship between quantity of target and decrease of frequency showed a typical saturation curve when concentrations of target HBV DNA varied from 10 pg/liter to 100 mu g/liter, and 10 mu g/liter was the watershed, with a statistic linear regression equation of I gC = -2.7455 + 0.0691 Delta F and the correlating coefficient of 0.9923. Fortunately, this is exactly the most ordinary variant range of the HBV virus concentration in clinical hepatitis samples. So, a good technical platform is successfully constructed and it will be applied to detect HBV quantitatively in clinical samples.
引用
收藏
页码:1266 / 1272
页数:7
相关论文
共 43 条
[11]  
FAWCETT NC, 1988, ANAL LETT, V21, P1099
[12]  
FRANK C, 1997, ANAL CHEM, V69, P2043
[13]   Effect of temperature and ionic strength on the dissociation kinetics and lifetime of PNA-DNA triplexes [J].
Kosaganov, YN ;
Stetsenko, DA ;
Lubyako, EN ;
Kvitko, NP ;
Lazurkin, YS ;
Nielsen, PE .
BIOCHEMISTRY, 2000, 39 (38) :11742-11747
[14]   An experimental study of mechanism and specificity of peptide nucleic acid (PNA) binding to duplex DNA [J].
Kuhn, H ;
Demidov, VV ;
Nielsen, PE ;
Frank-Kamenetskii, MD .
JOURNAL OF MOLECULAR BIOLOGY, 1999, 286 (05) :1337-1345
[15]   Study of DNA hybridization on polypyrrole grafted with oligonucleotides by photocurrent spectroscopy [J].
Lassalle, N ;
Vieil, E ;
Correia, JP ;
Abrantes, LM .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (4-5) :295-303
[16]   Study on colloidal Au-enhanced DNA sensing by quartz crystal microbalance [J].
Lin, L ;
Zhao, HQ ;
Li, JR ;
Tang, JA ;
Duan, MX ;
Jiang, L .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2000, 274 (03) :817-820
[17]   A theoretical analysis of specificity of nucleic acid interactions with oligonucleotides and peptide nucleic acids (PNAs) [J].
Lomakin, A ;
Frank-Kamenetskii, MD .
JOURNAL OF MOLECULAR BIOLOGY, 1998, 276 (01) :57-70
[18]   Quartz crystal microbalance (QCM) affinity biosensor for genetically modified organisms (GMOs) detection [J].
Mannelli, I ;
Minunni, M ;
Tombelli, S ;
Mascini, M .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (2-3) :129-140
[19]   Monitoring, and estimation of kinetic data, by piezoelectric impedance analysis, of the binding of the anticancer drug mitoxantrone to surface-immobilized DNA [J].
Mao, YA ;
Wei, WZ ;
Zhang, SF ;
Zeng, GM .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (4-5) :215-221
[20]   RETRACTED: Detection of human apolipoprotein E genotypes by DNA biosensors coupled with PCR (Retracted article. See vol. 329, pg. 157, 2003) [J].
Marrazza, G ;
Tombelli, S ;
Mascini, N ;
Manzoni, A .
CLINICA CHIMICA ACTA, 2001, 307 (1-2) :241-248