Surface treated large bore catheters with silver based coatings versus untreated catheters for extracorporeal detoxification methods

被引:21
作者
Bambauer, R [1 ]
Mestres, P
Schiel, R
Schneidewind, JM
Goudjinou, R
Latza, R
Inniger, R
Bambauer, S
Sioshansi, P
机构
[1] Univ Saarland, Inst Blood Purificat, D-66424 Homburg, Germany
[2] Univ Saarland, Inst Anat, D-66424 Homburg, Germany
[3] Krankenhaus Gummersbach, Gummersbach, Germany
[4] Spire Corp, Bedford, MA 01730 USA
关键词
D O I
10.1097/00002480-199807000-00012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Infection, thrombosis, and stenosis are among the most frequent complications associated with blood contacting catheters. Because these problems are usually related to surface properties of the base catheter material, surface treatment processes, such as ion implantation and ion beam assisted deposition (silver based coatings), can be used to mitigate such complications. Because these ion beam based processes affect only the near-surface region (approximately the outer 1 mu m), there is little effect on bulk material properties. This study evaluated silver coated large bore catheters used for extracorporeal detoxification. In a 122 patient prospective study, 156 large bore catheters were inserted into the internal jugular or subclavian veins. Seventy-eight surface treated catheters (SPI-ARGENT, Spire Corporation, Bedford, MA; n = 32 acute catheters, n = 45 long-term catheters) were Bambauer inserted in 55 patients. Seventy-eight untreated catheters placed in 67 patients served as controls (n = 35 acute catheters, n = 43 long-term catheters). After removal, the catheters were cultured for bacterial colonization using standard microbiologic assays. They were also examined using a scanning electron microscope (SEM). Bacterial colonization was observed in 15.4% of the treated catheters compared with 44.9% of untreated catheters. The SEM investigations showed all treated catheters to possess low thrombogenicity. Results of the study indicate that ion beam based processes can be used to improve thrombus and infection resistance of blood contacting catheters.
引用
收藏
页码:303 / 308
页数:6
相关论文
共 31 条
[1]   RASTER-ELECTRON-MICROSCOPIC INVESTIGATIONS IN LARGE-BORE CATHETERS FOR EXTRACORPOREAL DETOXIFICATION [J].
BAMBAUER, R ;
MESTRES, P ;
PIROUNG, KJ .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1990, 13 (10) :667-671
[2]  
BAMBAUER R, 1982, DIALYSIS TRANSPLANT, V11, P766
[3]  
Bambauer R, 1992, ASAIO J, V38, P96, DOI 10.1097/00002480-199204000-00006
[4]   Scanning electron microscopic investigation of catheters for blood access [J].
Bambauer, R ;
Schiel, R ;
Mestres, P ;
Klinkmann, J ;
Sioshansi, P .
BLOOD PURIFICATION, 1996, 14 (03) :249-256
[5]  
BAMBAUER R, 1995, DIALYSIS TRANSPLANT, V24, P228
[6]   SCANNING ELECTRON-MICROSCOPIC INVESTIGATION OF CATHETERS FOR BLOOD ACCESS [J].
BAMBAUER, R ;
MESTRES, P ;
PIRRUNG, KJ ;
SIOSHANSI, P .
ARTIFICIAL ORGANS, 1994, 18 (04) :272-275
[7]   SCANNING ELECTRON-MICROSCOPIC INVESTIGATIONS OF LARGE-BORE CATHETERS USED FOR EXTRACORPOREAL DETOXIFICATION METHODS [J].
BAMBAUER, R ;
MESTRES, P ;
PIRRUNG, KJ ;
INNIGER, R .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 1993, 77 (02) :171-177
[8]  
BAMBAUER R, 1994, ECC INT, V6, P5
[9]  
BAMBAUER S, 1996, COST REDUCTION BENEF
[10]  
DECUBBER A, 1978, DIALYSIS TRANSPLANT, V7, P1261