Characterization of an attenuated total reflection-based sensor for integrated solid-phase extraction and infrared detection

被引:20
作者
Alcudia-Leon, M. Carmen [1 ]
Lucena, Rafael [1 ]
Cardenas, Soledad [1 ]
Valcarcel, Miguel [1 ]
机构
[1] Univ Cordoba, Dept Analyt Chem, E-14071 Cordoba, Spain
关键词
D O I
10.1021/ac0713757
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel attenuated total reflection (ATR) sensor, which integrates solid-phase extraction (SPE) and infrared detection, is presented. The flow cell, which enables the online coupling with a sequential injection system, is the core of the proposed sensor since it allows the continuous delivery of different solutions through the ATR and also the continuous spectrum acquisition. A SPE sorbent material (LiChrolut EN) was located in the sensitive element of the ATR without using any external coating substance, increasing the versatility of the system. A marked sensitivity enhancement was obtained as the analyte was concentrated before detection. The new sensor was qualitatively and quantitatively validated using the determination of caffeine in soft drinks as the model analytical problem. Umearity, precision (RSD = 4%), and sensitivity (LOD = 7 eta g/mL) levels have been established. Finally, the main advantages and limitations of the new proposal are presented and compared with existing alternatives.
引用
收藏
页码:1146 / 1151
页数:6
相关论文
共 21 条
[1]   Microorganism characterization using ATR-FTIR on an ultrathin polystyrene layer [J].
Branan, Nicole ;
Wells, Todd A. .
VIBRATIONAL SPECTROSCOPY, 2007, 44 (01) :192-196
[2]   Flow injection Fourier transform infrared determination of caffeine in soft drinks [J].
Daghbouche, Y ;
Garrigues, S ;
Vidal, MT ;
delaGuardia, M .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :1086-1091
[3]   FTIR-determination of sterols from the red alga Asparagopsis armata:: Comparative studies with HPLC [J].
El Hattab, N ;
Daghbouche, Y ;
El Hattab, M ;
Piovetti, L ;
Garrigues, S ;
de la Guardia, M .
TALANTA, 2006, 68 (04) :1230-1235
[4]   The development of novel organically modified sol-gel media for use with ATR/FTIR sensing [J].
Flavin, K. ;
Mullowney, J. ;
Murphy, B. ;
Owens, E. ;
Kirwan, P. ;
Murphy, K. ;
Hughes, H. ;
McLoughlin, P. .
ANALYST, 2007, 132 (03) :224-229
[5]   Infrared detection in flow analysis - developments and trends (review) [J].
Gallignani, M ;
Brunetto, MD .
TALANTA, 2004, 64 (05) :1127-1146
[6]   Attenuated total reflection infrared spectroscopy of proteins and lipids in biological membranes [J].
Goormaghtigh, E ;
Raussens, V ;
Ruysschaert, JM .
BIOCHIMICA ET BIOPHYSICA ACTA-REVIEWS ON BIOMEMBRANES, 1999, 1422 (02) :105-185
[7]   Blood diagnostics using fiberoptic evanescent wave spectroscopy and neural networks analysis [J].
Gotshal, Y ;
Simhi, R ;
Sela, BA ;
Katzir, A .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 42 (03) :157-161
[8]   At the solid/liquid interface: FTIR/ATR - the tool of choice [J].
Hind, AR ;
Bhargava, SK ;
McKinnon, A .
ADVANCES IN COLLOID AND INTERFACE SCIENCE, 2001, 93 (1-3) :91-114
[9]   Towards a remote IR fiber-optic sensor system for the determination of chlorinated hydrocarbons in water [J].
Jakusch, M ;
Mizaikoff, B ;
Kellner, R .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 38 (1-3) :83-87
[10]   Simultaneous quantitative determination of benzene, toluene, and xylenes in water using mid-infrared evanescent field spectroscopy [J].
Karlowatz, M ;
Kraft, M ;
Mizalkoff, B .
ANALYTICAL CHEMISTRY, 2004, 76 (09) :2643-2648