Intravascular ultrasound evaluation of optimal drug-eluting stent expansion after poststent balloon dilation using a noncompliant balloon versus a semicompliant balloon (from the poststent optimal stent expansion trial [POET])

被引:12
作者
Kim, Jung-Sun [1 ]
Moon, Jae-Youn [2 ]
Ko, Young-Guk [1 ]
Choi, Donghoon [1 ]
Jang, Yangsoo [1 ]
Kang, Woong Chol [3 ]
Ahn, Taehoon [3 ]
Kim, Byoung-Keuk [4 ]
Oh, Seong Jin [4 ]
Jeon, Dong Woon [4 ]
Yang, Joo-Young [4 ]
机构
[1] Yonsei Univ, Coll Med, Ctr Cardiovasc, Div Cardiol, Seoul 120749, South Korea
[2] Pochon CHA Univ, Coll Med, Dept Internal Med, Songnam, South Korea
[3] Gachon Med Sch, Div Cardiol, Inchon, South Korea
[4] NHIC Ilsan Hosp, Div Cardiol, Koyang, South Korea
关键词
D O I
10.1016/j.amjcard.2008.03.059
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The impact of type of balloon such as noncompliant (NC; Quantum) or semicompliant (SC; Maverick 2) used after stent dilation on optimal stent expansion (OSE) has not been established for drug-eluting stents (DESs). We conducted a prospective multicenter, randomized study to compare NC with SC balloons after stent balloon dilatation. A total of 301 patients (127 men, 83 women, 62 +/- 9 years of age) treated with a DES (sirolimus-eluting stent [SES], n = 152; paclitaxel-eluting stent, n = 149) were included. OSE followed the definition of the Multicenter Ultrasound Stenting in Coronaries (MUSIC) study. The primary end point was the incidence of OSE using intravascular ultrasound according to type of balloon. Baseline characteristics of each group showed no significant differences. OSE in the SC balloon group was achieved at higher rates than the NC balloon group (53 +/- 35%, vs 73 +/- 48%, p = 0.022 in all stents; 25 +/- 33%, vs 36, 48%, p = 0.051 in SESs). However, any differences in the achievement of OSE between the NC and SC balloon groups were not present in paclitaxel-eluting stents. In conclusion, despite postadjuvant balloon inflations with high pressures, underexpansion of the DES was seen commonly. Between the 2 types of balloon for adjuvant dilation after DES implantation, same-size SC balloons could be more useful for obtaining OSE than NC balloons, especially in SESs. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:304 / 310
页数:7
相关论文
共 17 条
[1]  
Brodie Bruce R, 2006, J Interv Cardiol, V19, P43, DOI 10.1111/j.1540-8183.2006.00103.x
[2]   Underexpansion of sirollimus-elluting stents: Incidence and relationship to delivery pressure [J].
Cheneau, E ;
Satler, LF ;
Escolar, E ;
Suddath, WI ;
Kent, KM ;
Weissman, NJ ;
Waksman, R ;
Pichard, AD .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 65 (02) :222-226
[3]   Intravascular ultrasound-guided optimized stent deployment - Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study) [J].
de Jaegere, P ;
Mudra, H ;
Figulla, H ;
Almagor, Y ;
Doucet, S ;
Penn, I ;
Colombo, A ;
Hamm, C ;
Bartorelli, A ;
Rothman, M ;
Nobuyoshi, M ;
Yamaguchi, T ;
Voudris, V ;
DiMario, C ;
Makovski, S ;
Hausmann, D ;
Rowe, S ;
Rabinovich, S ;
Sunamura, M ;
van Es, GA .
EUROPEAN HEART JOURNAL, 1998, 19 (08) :1214-1223
[4]  
Desmet WJ, 1997, CATHETER CARDIO DIAG, V41, P5, DOI 10.1002/(SICI)1097-0304(199705)41:1<5::AID-CCD3>3.0.CO
[5]  
2-C
[6]   Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting Stent implantation [J].
Fujii, K ;
Carlier, SG ;
Mintz, GS ;
Yang, YM ;
Moussa, I ;
Weisz, G ;
Dangas, G ;
Mehran, R ;
Lansky, AJ ;
Kreps, EM ;
Collins, M ;
Stone, GW ;
Lansky, AJ ;
Kreps, EM ;
Collins, M ;
Stone, GW ;
Moses, JW ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (07) :995-998
[7]   Comparison of aggressive versus nonaggressive balloon dilatation for stent deployment on late loss and restenosis in native coronary arteries [J].
Goldberg, SL ;
Di Mario, C ;
Hall, P ;
Colombo, A .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (06) :708-712
[8]   Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation [J].
Hong, Myeong-Ki ;
Mintz, Gary S. ;
Lee, Cheol Whan ;
Park, Duk-Woo ;
Choi, Bong-Ryong ;
Park, Kyoung-Ha ;
Kim, Young-Hak ;
Cheong, Sang-Sig ;
Song, Jae-Kwan ;
Kim, Jae-Joong ;
Park, Seong-Wook ;
Park, Seung-Jung .
EUROPEAN HEART JOURNAL, 2006, 27 (11) :1305-1310
[9]   Efficacy of postdeployment balloon dilatation for current generation stents as assessed by intravascular ultrasound [J].
Hur, SH ;
Kitamura, K ;
Morino, Y ;
Honda, Y ;
Jones, M ;
Korr, KS ;
Reen, B ;
Cooper, CJ ;
Niess, GS ;
Christie, L ;
Corey, W ;
Messenger, J ;
Yock, PG ;
Cummins, F ;
Fitzgerald, PJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (10) :1114-1119
[10]   Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents [J].
Iakovou, I ;
Schmidt, T ;
Bonizzoni, E ;
Ge, L ;
Sangiorgi, GM ;
Stankovic, G ;
Airoldi, F ;
Chieffo, A ;
Montorfano, M ;
Carlino, M ;
Michev, I ;
Corvaja, N ;
Briguori, C ;
Gerckens, U ;
Grube, E ;
Colombo, A .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (17) :2126-2130