Evaluation of regional pulmonary perfusion using ultrafast magnetic resonance imaging

被引:91
作者
Levin, DL [1 ]
Chen, Q [1 ]
Zhang, M [1 ]
Edelman, RR [1 ]
Hatabu, H [1 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
关键词
MRI; pulmonary circulation; human studies; contrast studies; lung imaging;
D O I
10.1002/mrm.1172
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An ultrafast MR sequence was used to measure changes in signal intensity during the first pass of intravascular contrast through the pulmonary circulation, From this, mean transit time, relative blood volume, and relative blood flow were calculated, Data were collected in an isogravitational plane in six healthy subjects, A slight hut significant gradient in transit time was present, with faster times at the lung apex. A significant decrease in blood volume, compared with the lung base, was also seen in the apex. Significant decreases in blood volume and blood flow, compared with central portions of the lung, were seen in the lung periphery, Six additional subjects were imaged along a gravitational plane, A significant gradient in transit time was seen, with faster transit in dependent regions of the lung. MRI is. able to evaluate regional differences in pulmonary perfusion with high spatial and temporal resolution, Magn Reson Med 46:166-171, 2001. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:166 / 171
页数:6
相关论文
共 26 条
[1]   A SINGLE-STEP METHOD FOR ESTIMATION OF LOCAL CEREBRAL BLOOD-VOLUME FROM SUSCEPTIBILITY CONTRAST MRI IMAGES [J].
BAHN, MM .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (03) :309-317
[2]   INTERRELATIONSHIPS BETWEEN REGIONAL BLOOD-FLOW, BLOOD-VOLUME, AND VENTILATION IN SUPINE HUMANS [J].
BRUDIN, LH ;
RHODES, CG ;
VALIND, SO ;
JONES, T ;
HUGHES, JMB .
JOURNAL OF APPLIED PHYSIOLOGY, 1994, 76 (03) :1205-1210
[3]   Pulmonary disorders: Ventilation-perfusion MR imaging with animal models [J].
Chen, Q ;
Levin, DL ;
Kim, D ;
David, V ;
McNicholas, M ;
Chen, V ;
Jakob, PM ;
Griswold, MA ;
Goldfarb, JW ;
Hatabu, H ;
Edelman, RR .
RADIOLOGY, 1999, 213 (03) :871-879
[4]   Water diffusion and exchange as they influence contrast enhancement [J].
Donahue, KM ;
Weisskoff, RM ;
Burstein, D .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (01) :102-110
[5]   VALIDATION OF FLUORESCENT-LABELED MICROSPHERES FOR MEASUREMENT OF REGIONAL ORGAN PERFUSION [J].
GLENNY, RW ;
BERNARD, S ;
BRINKLEY, M .
JOURNAL OF APPLIED PHYSIOLOGY, 1993, 74 (05) :2585-2597
[6]   GRAVITY-INDEPENDENT INEQUALITY IN PULMONARY BLOOD-FLOW IN HUMANS [J].
HAKIM, TS ;
LISBONA, R ;
DEAN, GW .
JOURNAL OF APPLIED PHYSIOLOGY, 1987, 63 (03) :1114-1121
[7]   EFFECT OF BODY POSTURE ON SPATIAL-DISTRIBUTION OF PULMONARY BLOOD-FLOW [J].
HAKIM, TS ;
DEAN, GW ;
LISBONA, R .
JOURNAL OF APPLIED PHYSIOLOGY, 1988, 64 (03) :1160-1170
[8]   Pulmonary perfusion: Qualitative assessment with dynamic contrast-enhanced MRI using ultra-short TE and inversion recovery turbo FLASH [J].
Hatabu, H ;
Gaa, J ;
Kim, D ;
Li, W ;
Prasad, PV ;
Edelman, RR .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) :503-508
[9]  
Hatabu H, 1999, MAGNET RESON MED, V42, P1033, DOI 10.1002/(SICI)1522-2594(199912)42:6<1033::AID-MRM7>3.0.CO
[10]  
2-7