Novel flow injection strategies for study and control of matrix interferences by inductively coupled plasma time-of-flight mass spectrometry

被引:19
作者
McClenathan, DM [1 ]
Ray, SJ [1 ]
Hieftje, GM [1 ]
机构
[1] Indiana Univ, Dept Chem, Bloomington, IN 47405 USA
关键词
D O I
10.1039/b104047m
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Inductively coupled plasma time-of-flight mass spectrometry is ideally suited for use with flow injection because of its virtually simultaneous multi-elemental and multi-isotope capabilities. Here, novel flow injection strategies are employed for characterizing matrix interferences, as a diagnostic tool for detecting interferences and as a method for calculating the dilution factors necessary to overcome interferences. Gradient dilution flow injection allows rapid characterization of interferences and avoids problems that arise in steady-state evaluations, such Lis orifice clogging and baseline drift. Unfortunately, more severe matrix effects are obtained with this technique than in steady-state experiments. In addition, by calculating analyte ratios across the flow injection profile, it is possible to diagnose interference effects as well as to determine the dilution factors necessary for alleviating the interference. However, at this time, this ratio technique is not completely effective, as it is limited by element-specific dispersion Curves. Unlike conventional interference approaches that are often time-consuming, these methods offer efficient alternatives for evaluating and possibly avoiding matrix effects.
引用
收藏
页码:987 / 990
页数:4
相关论文
共 9 条
[1]   Trace metal analysis of natural waters and biological samples by axial inductively coupled plasma time of flight mass spectrometry (ICP-TOFMS) with flow injection on-line adsorption preconcentration using a knotted reactor [J].
Benkhedda, K ;
Infante, HG ;
Ivanova, E ;
Adams, FC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (10) :1349-1356
[2]   Flow injection analysis with inductively coupled plasma time-of-flight mass spectrometry for the simultaneous determination of elements forming hydrides and its application to urine [J].
Centineo, G ;
Bayón, MM ;
Sanz-Medel, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (10) :1357-1362
[3]   INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY - A REVIEW [J].
EVANS, EH ;
GIGLIO, JJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (01) :1-18
[4]  
Ruzicka Jaromir., 1988, FLOW INJECTION ANAL, V2nd
[5]  
SANZMEDEL A, 1999, ANAL SPECTROSCOPY LI, V9, P467
[6]   EXPANSION OF DYNAMIC WORKING RANGE AND CORRECTION FOR INTERFERENCES IN FLAME ATOMIC-ABSORPTION SPECTROMETRY USING FLOW-INJECTION GRADIENT RATIO CALIBRATION WITH A SINGLE STANDARD [J].
SPERLING, M ;
FANG, ZL ;
WELZ, B .
ANALYTICAL CHEMISTRY, 1991, 63 (02) :151-159
[7]   Analytical performance of axial inductively coupled plasma time of flight mass spectrometry (ICP-TOFMS) [J].
Tian, XD ;
Emteborg, H ;
Adams, FC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (12) :1807-1814
[8]   FLOW-INJECTION TECHNIQUES OF METHOD DEVELOPMENT FOR FLAME ATOMIC-ABSORPTION SPECTROMETRY [J].
TYSON, JF ;
ADEEYINWO, CE ;
APPLETON, JMH ;
BYSOUTH, SR ;
IDRIS, AB ;
SARKISSIAN, LL .
ANALYST, 1985, 110 (05) :487-492
[9]   Evaluation of the isotope ratio performance of an axial time-of-flight ICP mass spectrometer [J].
Vanhaecke, F ;
Moens, L ;
Dams, R ;
Allen, L ;
Georgitis, S .
ANALYTICAL CHEMISTRY, 1999, 71 (15) :3297-3303