Flow-injection system with glucose oxidase immobilized on a tubular reactor for determination of glucose in blood samples

被引:14
作者
de Oliveira, ACA [1 ]
Assis, VC [1 ]
Matos, MAC [1 ]
Matos, RC [1 ]
机构
[1] Univ Fed Juiz De Fora, Inst Ciencias Exatas, Dept Quim, BR-36038300 Juiz De Fora, MG, Brazil
关键词
glucose oxidase; glucose; blood; flow-injection system; spectrophotometric detection;
D O I
10.1016/j.aca.2004.11.053
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A spectrophotometric method for the determination of glucose in blood sample is proposed. This method is based on selective oxidation of beta-D-glucose to D-gluconate and hydrogen peroxide using an on-line tubular reactor containing glucose oxidase immobilized on Amberlite IRA-743 resin. The hydrogen peroxide, in the presence of phenol, 4-aminoantipyrine and peroxidase, produces a red compound (lambda(max) = 505 mn). Beer's law is obeyed in a concentration range of 10-100 mu mol/L glucose with an excellent correlation coefficient (r = 0.9991), at pH 6.5, with a relative standard deviation (R.S.D) < 3%. The flow rate of 2.0 mL/min and injecting 200 mu l sample volumes was adopted. The detection limit of the method is 5.7 mu mol/l. Rectors prepared, presented high stability for at last I week under intense use in flowing solutions. The results show a simple, accurate, selective and readily applied method to the determination of glucose in blood sample. The analytical results obtained for these products by the proposed method are in agreement with those of obtained by the classical the spectrophotometric method with enzyme, free in solution. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:213 / 217
页数:5
相关论文
共 22 条
[1]   A FIA procedure for enzymatic determination of high glucose concentrations. Application to parenteral solutions analysis [J].
Barrado, E ;
Vela, MH ;
Lapa, RAS ;
Lima, JLFC .
ANALUSIS, 1999, 27 (02) :170-174
[2]   ENZYME MEMBRANE BASED UPON POLYAMIDE-6 FOR OIL HYDROLYSIS [J].
CEYNOWA, J ;
ADAMCZAK, P .
JOURNAL OF APPLIED POLYMER SCIENCE, 1992, 46 (05) :749-755
[3]   DISTRIBUTION OF IMMOBILIZED ENZYMES ON POROUS MEMBRANES [J].
DALVIE, SK ;
BALTUS, RE .
BIOTECHNOLOGY AND BIOENGINEERING, 1992, 40 (10) :1173-1180
[4]   SPECTROPHOTOMETRIC DETERMINATION OF HYDROGEN-PEROXIDE USING O-HYDROXYHYDROQUINONEPHTHALEIN, TITANIUM(IV) AND ETHYLENEDIAMINETETRAACETIC ACID [J].
FUJITA, Y ;
MORI, I ;
TOYODA, M ;
MATSUO, T .
ANALYTICAL SCIENCES, 1994, 10 (05) :827-830
[5]   ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
GUILBAULT, GG ;
LUBRANO, GJ .
ANALYTICA CHIMICA ACTA, 1973, 64 (03) :439-455
[6]   AMPEROMETRIC FLOW-INJECTION TECHNIQUE FOR DETERMINATION OF HYDROGEN-PEROXIDE AND SULFUR(IV) IN ATMOSPHERIC LIQUID WATER [J].
GUTZ, IGR ;
KLOCKOW, D .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 335 (08) :919-923
[7]   A versatile and pulsation free pneumatic impeller for flow analysis systems [J].
Matos, RC ;
Gutz, IGR ;
Angnes, L ;
Fontenele, RS ;
Pedrotti, JJ .
QUIMICA NOVA, 2001, 24 (06) :795-798
[8]   Flow-injection system with enzyme reactor for differential amperometric determination of hydrogen peroxide in rainwater [J].
Matos, RC ;
Pedrotti, JJ ;
Angnes, L .
ANALYTICA CHIMICA ACTA, 2001, 441 (01) :73-79
[9]  
MEIZERAITYTE M, 1987, BIOTECHNOLOGY, V3, P661
[10]  
MILLER JC, 1992, STAT ANAL CHEM