Selective determination of Ni(II) and Co(II) by flow injection analysis and adsorptive cathodic stripping voltammetry on a wall jet mercury film electrode

被引:52
作者
Economou, A [1 ]
Fielden, PR [1 ]
机构
[1] Univ Manchester, Inst Sci & Technol, Dept Instrumentat & Analyt Sci, POB 88, Manchester M60 1QD, Lancs, England
关键词
nickel; cobalt; adsorptive cathodic stripping voltammetry; flow injection analysis;
D O I
10.1016/S0039-9140(97)00381-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ni(II) and Co(II) have been determined simultaneously by means of adsorptive cathodic stripping voltammetry (AdCSV) in a computerised flow injection system. The working electrode was a glassy carbon disk that was fitted in a wall-jet flow cell. The electrode was initially electrochemically coated with a mercury film at - 1.0 V by injecting a HE(II) solution in the flow stream. Then, the sample, containing Ni(II) and Co(II), was mixed on-line with a solution containing dimethylgyoxime (DMG) at pH 9 in order to selectively complex the metal ions and was injected in the flow system. After a number of successive injections during which accumulation took place under controlled potentiostatic conditions, the surface-bound complexes were reduced in ammonia buffer at pH 9 by a cathodic scan of the potential of the working electrode in the square wave mode and the current-potential response was recorded. Finally, the electrode surface was regenerated by a potentiostatic polarisation at - 1.4 V in the same buffer. The apparatus could be easily converted for continuous flow accumulation in order to increase the sensitivity; in this mode of operation, instead of performing discrete injections, the sample was continuously pumped through the cell. Various parameters associated with the preconcentration. stripping and regeneration steps were optimised for the determination of Ni(II) and Co(II). The selectivity of the method was demonstrated for the analysis of high purity iron; the accuracy for the determination of Ni(II) and Co(II) was 11 and 3%, respectively while the coefficient of variation was 10 and 8%, respectively. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1137 / 1146
页数:10
相关论文
共 20 条
[1]   ASSESSMENT OF DIFFERENTIAL-PULSE ADSORPTION VOLTAMMETRY FOR THE SIMULTANEOUS DETERMINATION OF NICKEL AND COBALT IN BIOLOGICAL-MATERIALS [J].
ADELOJU, SB ;
BOND, AM ;
BRIGGS, MH .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :181-194
[2]   Batch injection analysis with adsorptive stripping voltammetry for the determination of traces of nickel and cobalt [J].
Brett, CMA ;
Brett, AMO ;
Tugulea, L .
ELECTROANALYSIS, 1996, 8 (07) :639-642
[3]   ADSORPTIVE STRIPPING VOLTAMMETRY OF COBALT AND NICKEL IN FLOW SYSTEMS AT WALL-JET ELECTRODES [J].
BRETT, CMA ;
BRETT, AMCFO ;
PEREIRA, JLC .
ELECTROANALYSIS, 1991, 3 (07) :683-689
[4]   Square wave adsorptive stripping voltammetry of nickel and cobalt at wall-jet electrodes in continuous flow [J].
Brett, CMA ;
Garcia, MBQ ;
Lima, JLFC .
ELECTROANALYSIS, 1996, 8 (12) :1169-1173
[5]   AUTOMATIC ADSORPTIVE STRIPPING VOLTAMMETRY AT THIN-MERCURY FILM ELECTRODES (TMFE) - THE HIGHLY-REPRODUCIBLE PLATING AND RENEWING OF THIN MERCURY FILMS ON GLASSY-CARBON FOR THE DETERMINATION OF NICKEL [J].
DIEDERICH, HJ ;
MEYER, S ;
SCHOLZ, F .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 349 (8-9) :670-675
[6]   SQUARE-WAVE ADSORPTIVE STRIPPING VOLTAMMETRY ON MERCURY FILM ELECTRODES [J].
ECONOMOU, A ;
FIELDEN, PR .
ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) :27-34
[7]   ADSORPTIVE STRIPPING VOLTAMMETRY ON MERCURY FILM ELECTRODES IN THE PRESENCE OF SURFACTANTS [J].
ECONOMOU, A ;
FIELDEN, PR .
ANALYST, 1993, 118 (11) :1399-1404
[8]   Determination of copper(II) by anodic stripping voltammetry using a flow-through system [J].
Economou, A ;
Fielden, PR .
ANALYST, 1996, 121 (12) :1903-1906
[9]   SIMULTANEOUS DETERMINATION OF NICKEL(II) AND COBALT(II) BY SQUARE-WAVE ADSORPTIVE STRIPPING VOLTAMMETRY ON A ROTATING-DISK MERCURY FILM ELECTRODE [J].
ECONOMOU, A ;
FIELDEN, PR .
ANALYST, 1993, 118 (01) :47-51
[10]   Applications, potentialities and limitations of adsorptive stripping analysis on mercury film electrodes [J].
Economou, A ;
Fielden, PR .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1997, 16 (05) :286-292