Computer-aided placement of endosseous oral implants in patients after ablative tumour surgery: assessment of accuracy

被引:101
作者
Wagner, A
Wanschitz, F
Birkfellner, W
Zauza, K
Klug, C
Schicho, K
Kainberger, F
Czerny, C
Bergmann, H
Ewers, R
机构
[1] Univ Vienna, Hosp Craniomaxillofacial & Oral Surg, Sch Med, A-1090 Vienna, Austria
[2] Univ Vienna, Gen Hosp, Dept Biomed Engn & Phys, A-1090 Vienna, Austria
[3] Univ Vienna, Sch Dent, A-1090 Vienna, Austria
[4] Ludwig Boltzmann Inst Nucl Med & Endocrinol, Vienna, Austria
[5] Univ Vienna, Gen Hosp Vienna, Dept Radiol, Div Osteoradiol, A-1090 Vienna, Austria
关键词
accuracy; computer-aided surgery; implant dentistry; mutual information matching;
D O I
10.1034/j.1600-0501.2003.110812.x
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
The objective of this study was to evaluate the feasibility and accuracy of a novel surgical computer-aided navigation system for the placement of endosseous implants in patients after ablative tumour surgery. Pre-operative planning was performed by developing a prosthetic concept and modifying the implant position according to surgical requirements after high-resolution computed tomography (HRCT) scans with VISIT, a surgical planning and navigation software developed at the Vienna General Hospital. The pre-operative plan was transferred to the patients intraoperatively using surgical navigation software and optical tracking technology. The patients were HRCT-scanned again to compare the position of the implants with the pre-operative plan on reformatted CT-slices after matching of the pre- and post-operative data sets using the mutual information-technique. A total of 32 implants was evaluated. The mean deviation was 1.1 mm (range: 0-3.5 mm). The mean angular deviation of the implants was 6.4degrees (range: 0.4degrees- 17.4degrees, variance: 13.3degrees). The results demonstrate, that adequate accuracy in placing endosseous oral implants can be delivered to patients with most difficult implantologic situations.
引用
收藏
页码:340 / 348
页数:9
相关论文
共 30 条
[1]
DENTAL IMPLANT TREATMENT PLANNING WITH REFORMATTED COMPUTED-TOMOGRAPHY [J].
BESIMO, C ;
LAMBRECHT, JT ;
NIDECKER, A .
DENTOMAXILLOFACIAL RADIOLOGY, 1995, 24 (04) :264-267
[2]
Accuracy of implant treatment planning utilizing template-guided reformatted computed tomography [J].
Besimo, CE ;
Lambrecht, JT ;
Guindy, JS .
DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (01) :46-51
[3]
A modular software system for computer-aided surgery and its first application in oral implantology [J].
Birkfellner, W ;
Huber, K ;
Larson, A ;
Hanson, D ;
Diemling, M ;
Homolka, P ;
Bergmann, H .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (06) :616-620
[4]
Calibration of tracking systems in a surgical environment [J].
Birkfellner, W ;
Watzinger, F ;
Wanschitz, F ;
Ewers, R ;
Bergmann, H .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) :737-742
[5]
The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: an animal experimental study [J].
Duyck, J ;
Ronold, HJ ;
Van Oosterwyck, H ;
Naert, I ;
Sloten, JV ;
Ellingsen, JE .
CLINICAL ORAL IMPLANTS RESEARCH, 2001, 12 (03) :207-218
[6]
Biological factors contributing to failures of osseointegrated oral implants - (II). Etiopathogenesis [J].
Esposito, M ;
Hirsch, JM ;
Lekholm, U ;
Thomsen, P .
EUROPEAN JOURNAL OF ORAL SCIENCES, 1998, 106 (03) :721-764
[7]
Biological factors contributing to failures of osseointegrated oral implants (I). Success criteria and epidemiology [J].
Esposito, M ;
Hirsch, JM ;
Lekholm, U ;
Thomsen, P .
EUROPEAN JOURNAL OF ORAL SCIENCES, 1998, 106 (01) :527-551
[8]
Fortin T, 1995, J Image Guid Surg, V1, P53, DOI 10.1002/(SICI)1522-712X(1995)1:1<53::AID-IGS8>3.3.CO
[9]
2-B
[10]
IDENTIFICATION OF BONE QUALITY IN CONJUNCTION WITH INSERTION OF TITANIUM IMPLANTS - A PILOT-STUDY IN JAW AUTOPSY SPECIMENS [J].
FRIBERG, B ;
SENNERBY, L ;
ROOS, J ;
LEKHOLM, U .
CLINICAL ORAL IMPLANTS RESEARCH, 1995, 6 (04) :213-219