Dynamic cine mode imaging of the normal aortic valve using 16-channel multidetector row computed tomography

被引:23
作者
Baumert, B
Plass, A
Bettex, D
Alkadhi, H
Desbiolles, L
Wildermuth, S
Marincek, B
Boehm, T
机构
[1] Kantonsspital, Dept Radiol, CH-7000 Chur, Switzerland
[2] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[3] Univ Zurich Hosp, Clin Cardiovasc Surg, CH-8091 Zurich, Switzerland
[4] Univ Zurich Hosp, Inst Anesthesia, Div Cardiovasc Anesthesia, CH-8091 Zurich, Switzerland
关键词
computed tomography; MDCT; transesophageal echocardiography; aortic valve;
D O I
10.1097/01.rli.0000178363.79489.ef
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: We investigated the feasibility and image quality of dynamic cine-mode imaging of the normal aortic valve using multidetector row computed tomography (MDCT). Materials and Methods: We acquired contrast-enhanced retrospectively echocardiography (ECG)-gated cardiac MDCT datasets of 35 patients (mean age, 62 years; range, 53-77) who received a transoesophageal echocardiography (TOE) precedent to cardiac bypass graft surgery. Twenty data sets in 5% steps of the R-R interval were reconstructed, and data analysis was performed using a 4D software. Read-out of the MDCT data was performed in parallel and perpendicular planes, similar to TOE standard planes, by 2 independent, blinded readers using a 4-point Likert scale (best score: 4) for the following parameters: image quality of the aortic valve components, contrast media enhancement, contrast media inflow related artifacts, and ECG gating-related artifacts. The aortic valve area (AVA) was measured planimetrically and was compared between TOE and MDCT, Results: The best phase for assessing the open valve using MDCT was at 5% and the closed valve at 65% of the cardiac cycle. The mean image quality scores for cine-mode MDCT ranged between 3.26 and 3.75, with inter-reader agreements ranging between good (kappa = 0.723) and excellent (kappa = 1.00). They did not differ significantly from TOE scores for assessment of the closed and open valve. In transitional phases (close-to-open and open-to-close) TOE performed significantly better when compared with static MDCT images, whereas no significant difference was present between cinemode presentation of MDCT and TOE. Planimetric AVA measurements correlated significantly between TOE and MDCT (Pearson correlation coefficient, r = 0.96; P < 0.0001). Contrast media inflow-related and ECG gating related artifacts were rated as slightly compromising (scores 3.24 and 3.21). Conclusion: Retrospectively ECG-gated MDCT offers a noninvasive, accurate, and dynamic imaging method for quantitative and qualitative evaluation of the normal aortic valve allowing determination of morphology and function throughout the cardiac cycle. Further studies regarding assessment of diseased valves are necessary.
引用
收藏
页码:637 / 647
页数:11
相关论文
共 55 条
[1]   Comparison of image quality in contrast-enhanced coronary artery visualization by electron beam tomography and retrospectively electrocardiogram-gated multislice spiral computed tomography [J].
Achenbach, S ;
Giesler, T ;
Ropers, D ;
Ulzheimer, S ;
Anders, K ;
Wenkel, E ;
Pohle, K ;
Kachelriess, M ;
Derlien, H ;
Kalender, WA ;
Daniel, WG ;
Bautz, W ;
Baum, U .
INVESTIGATIVE RADIOLOGY, 2003, 38 (02) :119-128
[2]   CINEANGIOGRAPHY OF THE HEART IN A SINGLE BREATH HOLD WITH A SEGMENTED TURBOFLASH SEQUENCE [J].
ATKINSON, DJ ;
EDELMAN, RR .
RADIOLOGY, 1991, 178 (02) :357-360
[3]   Evaluation of spatial and temporal resolution for ECG-gated 16-row multidetector CT using a dynamic cardiac phantom [J].
Begemann, PGC ;
van Stevendaal, U ;
Manzke, R ;
Stork, A ;
Weiss, F ;
Nolte-Ernsting, C ;
Grass, M ;
Adam, G .
EUROPEAN RADIOLOGY, 2005, 15 (05) :1015-1026
[4]   Planimetry of aortic valve area using multiplane transoesophageal echocardiography is not a reliable method for assessing severity of aortic stenosis [J].
Bernard, Y ;
Meneveau, N ;
Vuillemenot, A ;
Magnin, D ;
Anguenot, T ;
Schiele, F ;
Bassand, JP .
HEART, 1997, 78 (01) :68-73
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]  
Blobel J, 2003, ROFO-FORTSCHR RONTG, V175, P1264
[7]   Time-effectiveness, observer-dependence, and accuracy of measurements of left ventricular ejection fraction using 4-channel MDCT [J].
Boehm, T ;
Alkadhi, H ;
Roffi, M ;
Willmann, JK ;
Desbiolles, LM ;
Marincek, B ;
Wildermuth, S .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (04) :529-537
[8]  
Bonow R O, 1998, J Heart Valve Dis, V7, P672
[9]   Reproducibility of electron-beam CT measures of aortic valve calcification [J].
Budoff, MJ ;
Mao, SS ;
Takasu, J ;
Shavelle, DM ;
Zhao, XQ ;
O'Brien, KD .
ACADEMIC RADIOLOGY, 2002, 9 (10) :1122-1127
[10]   Aortic valve calcification on computed tomography predicts the severity of aortic stenosis [J].
Cowell, SJ ;
Newby, DE ;
Burton, J ;
White, A ;
Northridge, DB ;
Boon, NA ;
Reid, J .
CLINICAL RADIOLOGY, 2003, 58 (09) :712-716