Investigation of TiO2 thick film capacitors for use as strain gauge sensors

被引:31
作者
Arshak, A [1 ]
Arshak, K
Morris, D
Korostynska, O
Jafer, E
机构
[1] Univ Limerick, Dept Phys, Limerick, Ireland
[2] Univ Limerick, Dept Elect & Comp Engn, Limerick, Ireland
关键词
TiO2; thick-film; capacitor; strain gauge;
D O I
10.1016/j.sna.2005.06.004
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this work the strain sensing properties of interdigitated and sandwich thick film capacitors, using titanium dioxide as the dielectric, are investigated. By pre-firing the TiO2 powder and forming a polymer thick film paste the use of expensive paste ingredients, such as ruthenium or palladium oxide, was avoided. After firing, XRD was used to verify the composition and crystallite size of the TiO2 powder, while SEM allowed the particle sizes of the powder to be examined. It was found that the powder has a crystallite and particle size, which is less than 1 mu m. Following this, the sensors were fabricated by screen-printing onto glass substrates and placed in a cantilever beam arrangement so that the change in their capacitance with strain could be measured. The gauge factor, which demonstrates the devices sensitivity, was found by dividing the fractional change in capacitance by the applied strain. A gauge factor of 5 and 30 was recorded for interdigitated and sandwich capacitors, respectively. In the case of sandwich capacitors, this gauge factor is higher than normally achieved using oxide films (3-15). Furthermore, the sensors showed a high degree of linearity with low hysteresis. The TCC has been measured for temperatures ranging from 25 to 70 degrees C so that the effect of temperature on the devices is known. Values, typical of thick film capacitors (876-2834 ppm/degrees C) have been recorded for temperatures up to 60 degrees C. Finally, ac electrical measurements have been used to shown that tunnelling is the dominant conduction mechanism within the TiO2 film. (C) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:242 / 249
页数:8
相关论文
共 28 条
[21]   Interdigital sensors and transducers [J].
Mamishev, AV ;
Sundara-Rajan, K ;
Yang, F ;
Du, YQ ;
Zahn, M .
PROCEEDINGS OF THE IEEE, 2004, 92 (05) :808-845
[22]   FABRICATING BIOMEDICAL SENSORS WITH THIN-FILM TECHNOLOGY [J].
NEUMAN, MR ;
BUCK, RP ;
COSOFRET, VV ;
LINDNER, E ;
LIU, CC .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1994, 13 (03) :409-419
[23]   Influence of substrate on the gauge factor of polymer thick-film resistors [J].
Papakostas, TV ;
White, NM .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2000, 33 (14) :L73-L75
[24]   LOW-FREQUENCY CONDUCTIVITY DUE TO HOPPING PROCESSES IN SILICON [J].
POLLAK, M ;
GEBALLE, TH .
PHYSICAL REVIEW, 1961, 122 (06) :1742-&
[25]   CAPACITIVE SENSORS - WHEN AND HOW TO USE THEM [J].
PUERS, R .
SENSORS AND ACTUATORS A-PHYSICAL, 1993, 37-8 :93-105
[26]   Thick-film sensors: Past, present and future [J].
White, NM ;
Turner, JD .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1997, 8 (01) :1-20
[27]   Preparation of anatase TiO2 supported on alumina by different metal organic chemical vapor deposition methods [J].
Zhang, XW ;
Zhou, MH ;
Lei, LC .
APPLIED CATALYSIS A-GENERAL, 2005, 282 (1-2) :285-293
[28]   Significant effect of lanthanide doping on the texture and properties of nanocrystalline mesoporous TiO2 [J].
Zhang, YH ;
Zhang, HX ;
Xu, YX ;
Wang, YG .
JOURNAL OF SOLID STATE CHEMISTRY, 2004, 177 (10) :3490-3498