Biosensor Regeneration: A Review of Common Techniques and Outcomes

被引:257
作者
Goode, J. A. [1 ,2 ]
Rushworth, J. V. H. [1 ,3 ]
Millner, P. A. [1 ]
机构
[1] Univ Leeds, Fac Biol Sci, Sch Biomed Sci, Leeds, W Yorkshire, England
[2] AbCam Plc, Cambridge, England
[3] De Montfort Univ, Fac Hlth & Life Sci, Sch Allied Hlth Sci, Leicester LE1 9BH, Leics, England
基金
英国生物技术与生命科学研究理事会;
关键词
QUARTZ-CRYSTAL MICROBALANCE; ANTIGEN-ANTIBODY BINDING; LABEL-FREE; PIEZOELECTRIC IMMUNOSENSOR; ELECTROCHEMICAL BIOSENSOR; MOLECULAR RECOGNITION; OPTICAL BIOSENSOR; AFFINITY SENSOR; HUMAN SERUM; QCM;
D O I
10.1021/la503533g
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Biosensors are ideally portable, low-cost tools for the rapid detection of pathogens, proteins, and other analytes. The global biosensor market is currently worth over 10 billion dollars annually and is a burgeoning field of interdisciplinary research that is hailed as a potential revolution in consumer, healthcare, and industrial testing. A key barrier to the widespread adoption of biosensors, however, is their cost. Although many systems have been validated in the laboratory setting and biosensors for a range of analytes are proven at the concept level, many have yet to make a strong commercial case for their acceptance. Though it is true with the development of cheaper electrodes, circuits, and components that there is a downward pressure on costs, there is also an emerging trend toward the development of multianalyte biosensors that is pushing in the other direction. One way to reduce the cost that is suitable for certain systems is to enable their reuse, thus reducing the cost per test. Regenerating biosensors is a technique that can often be used in conjunction with existing systems in order to reduce costs and accelerate the commercialization process. This article discusses the merits and drawbacks of regeneration schemes that have been proven in various biosensor systems and indicates parameters for successful regeneration based on a systematic review of the literature. It also outlines some of the difficulties encountered when considering the role of regeneration at the point of use. A brief meta-analysis has been included in this review to develop a working definition for biosensor regeneration, and using this analysis only similar to 60% of the reported studies analyzed were deemed a success. This highlights the variation within the field and the need to normalize regeneration as a standard process across the field by establishing a consensus term.
引用
收藏
页码:6267 / 6276
页数:10
相关论文
共 108 条
[91]   An integrated approach for the design and synthesis of oligonucleotide probes and their interfacing to a QCM-based RNA biosensor [J].
Tedeschi, L ;
Citti, L ;
Domenici, C .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (11) :2376-2385
[92]   Antibody immobilisation on fibre optic TIRF sensors [J].
Tedeschi, L ;
Domenici, C ;
Ahluwalia, A ;
Baldini, F ;
Mencaglia, A .
BIOSENSORS & BIOELECTRONICS, 2003, 19 (02) :85-93
[93]   Adhiron: a stable and versatile peptide display scaffold for molecular recognition applications [J].
Tiede, Christian ;
Tang, Anna A. S. ;
Deacon, Sarah E. ;
Mandal, Upasana ;
Nettleship, Joanne E. ;
Owen, Robin L. ;
George, Suja E. ;
Harrison, David J. ;
Owens, Raymond J. ;
Tomlinson, Darren C. ;
McPherson, Michael J. .
PROTEIN ENGINEERING DESIGN & SELECTION, 2014, 27 (05) :145-155
[94]   Role of salt bridge formation in antigen-antibody interaction - Entropic contribution to the complex between hen egg white lysozyme and its monoclonal antibody HyHEL10 [J].
Tsumoto, K ;
Ogasahara, K ;
Ueda, Y ;
Watanabe, K ;
Yutani, K ;
Kumagai, I .
JOURNAL OF BIOLOGICAL CHEMISTRY, 1996, 271 (51) :32612-32616
[95]   Porous gold surfaces for biosensor applications [J].
van Noort, D ;
Mandenius, CF .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (3-4) :203-209
[96]   HYDROPHOBIC, HYDROPHILIC AND OTHER INTERACTIONS IN EPITOPE PARATOPE BINDING [J].
VANOSS, CJ .
MOLECULAR IMMUNOLOGY, 1995, 32 (03) :199-211
[97]   Biosensors in fish production and quality control [J].
Venugopal, V .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (03) :147-157
[98]   Amperometric cholesterol biosensor based on in situ reconstituted cholesterol oxidase on an immobilized monolayer of flavin adenine dinucleotide cofactor [J].
Vidal, JC ;
Espuelas, J ;
Castillo, JR .
ANALYTICAL BIOCHEMISTRY, 2004, 333 (01) :88-98
[99]  
Voet V., 1998, FUNDAMENTALS BIOCH L
[100]   Highly parallel affinity sensor for the detection of environmental contaminants in water [J].
Weller, MG ;
Schuetz, AJ ;
Winklmair, M ;
Niessner, R .
ANALYTICA CHIMICA ACTA, 1999, 393 (1-3) :29-41