Tracking moving organs in real time

被引:251
作者
Murphy, MJ [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
[2] Accuray Inc, Sunnyvale, CA USA
关键词
D O I
10.1053/j.semradonc.2003.10.005
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
In an ideal radiotherapy procedure, the treatment system would continuously adapt the radiation beam delivery to changes in the tumor position. The development of such a tracking capability has been underway for more than 10 years, beginning with the CyberKnife image-guided radiosurgery system. In that time, much has been learned about the nature of tumor motion and the technical issues that it presents to a practical real-time tracking system. In this article, I will review the basic concepts behind existing and proposed radiotherapy beam-tracking systems, show clinical evidence of the types of movement that are encountered in real-time tracking situations, describe the corresponding technical problems and solutions, and discuss the unresolved issues in making real-time tumor tracking a practical response to tumor motion. © 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:91 / 100
页数:10
相关论文
共 33 条
[21]   The effectiveness of breath-holding to stabilize lung and pancreas tumors during radiosurgery [J].
Murphy, MJ ;
Martin, D ;
Whyte, R ;
Hai, J ;
Ozhasoglu, C ;
Le, QT .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (02) :475-482
[22]   The importance of computed tomography slice thickness in radiographic patient positioning for radiosurgery [J].
Murphy, MJ .
MEDICAL PHYSICS, 1999, 26 (02) :171-175
[23]   Synchronized moving aperture radiation therapy (SMART): average tumour trajectory for lung patients [J].
Neicu, T ;
Shirato, H ;
Seppenwoolde, Y ;
Jiang, SB .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (05) :587-598
[24]   Issues in respiratory motion compensation during external-beam radiotherapy [J].
Ozhasoglu, C ;
Murphy, MJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (05) :1389-1399
[25]  
PATIL CP, 1989, BMMODELING BREATH BR, P343
[26]   Image-guided hypo-fractionated stereotactic radiosurgery to spinal lesions [J].
Ryu, SI ;
Chang, SD ;
Kim, DH ;
Murphy, MJ ;
Le, QT ;
Martin, DP ;
Adler, JR .
NEUROSURGERY, 2001, 49 (04) :838-846
[27]  
Schweikard A, 2000, Comput Aided Surg, V5, P263, DOI 10.1002/1097-0150(2000)5:4<263::AID-IGS5>3.0.CO
[28]  
2-2
[29]   A novel tracking technique for the continuous precise measurement of tumour positions in conformal radiotherapy [J].
Seiler, PG ;
Blattmann, H ;
Kirsch, S ;
Muench, RK ;
Schilling, C .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (09) :N103-N110
[30]   Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy [J].
Seppenwoolde, Y ;
Shirato, H ;
Kitamura, K ;
Shimizu, S ;
van Herk, M ;
Lebesque, JV ;
Miyasaka, K .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (04) :822-834