The importance of computed tomography slice thickness in radiographic patient positioning for radiosurgery

被引:36
作者
Murphy, MJ [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
关键词
D O I
10.1118/1.598500
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new radiographic patient positioning technique developed for radiosurgery has been analyzed to show the effect of computed tomography (CT) slice thickness on the precision of target localization during treatment. The positioning technique establishes the pose of the patient's anatomy during treatment by comparing treatment room radiographs with digitally reconstructed radiographs derived from a CT study. The measured pose is then used to align the x-ray therapy beam with the treatment site, without resorting to mechanical fixation. The technique has been found to be sensitive to submillimeter changes in skull position, which is the level of precision desired for radiosurgery. In this report it is shown that the precision of head localization improves by a factor of 2 when the CT slice thickness is reduced from 3.0 to 1.5 mm. This indicates that, in radiosurgical applications, image-guided beam alignment can be significantly influenced by the spatial resolution of the reference CT study. This result is relevant to all high-precision radiographic positioning techniques that utilize CT images. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)00102-9].
引用
收藏
页码:171 / 175
页数:5
相关论文
共 10 条
[1]  
Adler JR, 1996, RADIOSURG, V1, P316
[2]   CORRELATION OF PROJECTION RADIOGRAPHS IN RADIATION-THERAPY USING OPEN CURVE SEGMENTS AND POINTS [J].
BALTER, JM ;
PELIZZARI, CA ;
CHEN, GTY .
MEDICAL PHYSICS, 1992, 19 (02) :329-334
[3]  
Brink J, 1995, HELICAL SPIRAL CT PR
[4]   An image correlation procedure for digitally reconstructed radiographs and electronic portal images [J].
Dong, L ;
Boyer, AL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1053-1060
[5]   A grey-level image alignment algorithm for registration of portal images and digitally reconstructed radiographs [J].
Hristov, DH ;
Fallone, BG .
MEDICAL PHYSICS, 1996, 23 (01) :75-84
[6]   A PATIENT-TO-COMPUTED-TOMOGRAPHY IMAGE REGISTRATION METHOD BASED ON DIGITALLY RECONSTRUCTED RADIOGRAPHS [J].
LEMIEUX, L ;
JAGOE, R ;
FISH, DR ;
KITCHEN, ND ;
THOMAS, DGT .
MEDICAL PHYSICS, 1994, 21 (11) :1749-1760
[7]   THE APPLICATION ACCURACY OF STEREOTAXIC FRAMES [J].
MACIUNAS, RJ ;
GALLOWAY, RL ;
LATIMER, JW .
NEUROSURGERY, 1994, 35 (04) :682-694
[8]   An automatic six-degree-of-freedom image registration algorithm for image-guided frameless stereotaxic radiosurgery [J].
Murphy, MJ .
MEDICAL PHYSICS, 1997, 24 (06) :857-866
[9]   The accuracy of dose localization for an image-guided frameless radiosurgery system [J].
Murphy, MJ ;
Cox, RS .
MEDICAL PHYSICS, 1996, 23 (12) :2043-2049
[10]  
SCHELL MC, 1995, 42 APPM TASK GROUP