An image correlation procedure for digitally reconstructed radiographs and electronic portal images

被引:67
作者
Dong, L
Boyer, AL
机构
[1] Department of Radiation Physics, The University of Texas M. D. Anderson Cancer Center, Houston, TX
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1995年 / 33卷 / 05期
关键词
treatment verification; digitally reconstructed radiographs; electronic portal imaging devices; image alignment; image correlation; three-dimensional conformal radiotherapy; virtual simulation;
D O I
10.1016/0360-3016(95)02082-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To study a procedure that uses megavoltage digitally reconstructed radiographs (DRRs) calculated from patient's three-dimensional (3D) computed tomography (CT) data as a reference image for correlation with on-line electronic portal images (EPIs) to detect patient setup errors. Methods and Materials: Megavoltage DRRs were generated by ray tracing through a modified volumetric CT data set in which CT numbers were converted into linear attenuation coefficients for the beam energy, The DRR transmission image was transformed to the grayscale window of the EPI by a histogram-matching technique, An alternative approach was to calibrate the transmission DRR using a measured response curve of the electronic portal imaging device (EPID). This forces the calculated transmission fluence values to be distributed in the same range as that of the EPID image, A cross-correlation technique was used to determine the degree of alignment of the patient anatomy found in the EPID image relative to the reference DRR. Results: Phantom studies demonstrated that the correlation procedure had a standard deviation of 0.5 mm and 0.5 degrees in aligning translational shifts and in-plane rotations, Systematic errors were found between a reference DRR and a reference EPID image, The automated grayscale image-correlation profess was completed within 3 s on a workstation computer or 12 s on a PC. Conclusion: The alignment procedure allows the direct comparison of a patient's treatment portal designed with a 3D planning computer with a patient's on-line portal image acquired at the treatment unit, The image registration process is automated to the extent that it requires minimal user intervention, and it is fast and accurate enough for on-line clinical applications.
引用
收藏
页码:1053 / 1060
页数:8
相关论文
共 21 条
[1]   CORRELATION OF PROJECTION RADIOGRAPHS IN RADIATION-THERAPY USING OPEN CURVE SEGMENTS AND POINTS [J].
BALTER, JM ;
PELIZZARI, CA ;
CHEN, GTY .
MEDICAL PHYSICS, 1992, 19 (02) :329-334
[2]   3-DIMENSIONAL VERIFICATION OF PATIENT PLACEMENT DURING RADIOTHERAPY USING PORTAL IMAGES [J].
BIJHOLD, J .
MEDICAL PHYSICS, 1993, 20 (02) :347-356
[3]   FAST EVALUATION OF PATIENT SET-UP DURING RADIOTHERAPY BY ALIGNING FEATURES IN PORTAL AND SIMULATOR IMAGES [J].
BIJHOLD, J ;
VANHERK, M ;
VIJLBRIEF, R ;
LEBESQUE, JV .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (12) :1665-1679
[4]  
BOYER A, 1992, MED PHYS, V19, P802
[5]   A SOLID WATER PHANTOM MATERIAL FOR RADIOTHERAPY X-RAY AND GAMMA-RAY BEAM CALIBRATIONS [J].
CONSTANTINOU, C ;
ATTIX, FH ;
PALIWAL, BR .
MEDICAL PHYSICS, 1982, 9 (03) :436-441
[6]  
DONG L, 1994, MED PHYS, V21, P886
[7]   METHODS FOR FULLY AUTOMATED VERIFICATION OF PATIENT SET-UP IN EXTERNAL-BEAM RADIOTHERAPY WITH POLYGON SHAPED FIELDS [J].
EILERTSEN, K ;
SKRETTING, A ;
TENNVASSAS, TL .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (06) :993-1012
[8]  
ESSERS M, 1994, MED PHYS, V21, P943
[9]  
GALL KP, 1993, MED PHYS, V20, P1153, DOI 10.1118/1.596969
[10]   AUTOMATIC ONLINE INSPECTION OF PATIENT SETUP IN RADIATION-THERAPY USING DIGITAL PORTAL IMAGES [J].
GILHUIJS, KGA ;
VANHERK, M .
MEDICAL PHYSICS, 1993, 20 (03) :667-677