Serum protein profiling by miniaturized solid-phase extraction and matrix-assisted laser desorption/ionization mass spectrometry

被引:49
作者
Callesen, AK
Mohammed, S
Bunkenborg, J
Kruse, TA
Cold, S
Mogensen, O
Christensen, RD
Vach, W
Jorgensen, PE
Jensen, ON [1 ]
机构
[1] Univ So Denmark, Dept Biochem & Mol Biol, Prot Res Grp, Odense, Denmark
[2] Odense Univ Hosp, Dept KKA Clin Biochem, DK-5000 Odense, Denmark
[3] Odense Univ Hosp, Dept Oncol, DK-5000 Odense, Denmark
[4] Univ So Denmark, Dept Stat & Demog, Odense, Denmark
关键词
D O I
10.1002/rcm.1960
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Serum profiling by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) holds promise as a clinical tool for early diagnosis of cancer and other human diseases. Sample preparation is key to achieving reproducible and well-resolved signals in MALDI-MS; a prerequisite for translation of MALDI-MS based diagnostic methods to clinical applications. We have investigated a number of MALDI matrices and several miniaturized solid-phase extraction (SPE) methods for serum protein concentration and desalting with the aim of generating reproducible, high-quality protein profiles by MALDI-MS. We developed a simple protocol for serum profiling that combines a matrix mixture of 2,5-dihydroxybenzoic acid and x-cyano-4-hydroxycinnarnic acid with miniaturized SPE and MALDI-MS. Functionalized membrane discs with hydrophobic, ion-exchange or chelating properties allowed reproducible MALDI mass spectra (m/z 1000-12000) to be obtained from serum. In a proof-of-principle application, SPE with chelating material and MALDI-MS identified protein peaks in serum that had been previously reported for distinguishing a person diagnosed with breast cancer from a control. These preliminary results indicate that this simple SPE/MALDI-MS method for serum profiling provides a versatile and scalable platform for clinical proteomics. Copyright (c) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:1578 / 1586
页数:9
相关论文
共 34 条
[11]   Identification and validation of a potential lung cancer serum biomarker detected by matrix-assisted laser desorption/ionization-time of flight spectra analysis [J].
Howard, BA ;
Wang, MZ ;
Campa, MJ ;
Corro, C ;
Fitzgerald, MC ;
Patz, EF .
PROTEOMICS, 2003, 3 (09) :1720-1724
[12]   MATRIX-ASSISTED LASER-DESORPTION IONIZATION MASS-SPECTROMETRY WITH ADDITIVES TO 2,5-DIHYDROXYBENZOIC ACID [J].
KARAS, M ;
EHRING, H ;
NORDHOFF, E ;
STAHL, B ;
STRUPAT, K ;
HILLENKAMP, F ;
GREHL, M ;
KREBS, B .
ORGANIC MASS SPECTROMETRY, 1993, 28 (12) :1476-1481
[13]  
Larsen MR, 2002, PROTEOMICS, V2, P1277, DOI 10.1002/1615-9861(200209)2:9<1277::AID-PROT1277>3.0.CO
[14]  
2-P
[15]   Combination of two matrices results in improved performance of MALDI MS for peptide mass mapping and protein analysis [J].
Laugesen, S ;
Roepstorff, P .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2003, 14 (09) :992-1002
[16]  
LI J, 2004, CLIN CHEM, V48, P1296
[17]  
Li JN, 2002, CLIN CHEM, V48, P1296
[18]   Human serum proteins preseparated by electrophoresis or chromatography followed by tandem mass spectrometry [J].
Marshall, J ;
Jankowski, A ;
Furesz, S ;
Kireeva, I ;
Barker, L ;
Dombrovsky, M ;
Zhu, WM ;
Jacks, K ;
Ingratta, L ;
Bruin, J ;
Kristensen, E ;
Zhang, RL ;
Stanton, E ;
Takahashi, M ;
Jackowski, G .
JOURNAL OF PROTEOME RESEARCH, 2004, 3 (03) :364-382
[19]   Processing of serum proteins underlies the mass spectral fingerprinting of myocardial infarction [J].
Marshall, J ;
Kupchak, P ;
Zhu, WM ;
Yantha, J ;
Vrees, T ;
Furesz, S ;
Jacks, K ;
Smith, C ;
Kireeva, I ;
Zhang, R ;
Takahashi, M ;
Stanton, E ;
Jackowski, G .
JOURNAL OF PROTEOME RESEARCH, 2003, 2 (04) :361-372
[20]   Clinical proteomics: Translating benchside promise into bedside reality [J].
Petricoin, EF ;
Zoon, KC ;
Kohn, EC ;
Barrett, JC ;
Liotta, LA .
NATURE REVIEWS DRUG DISCOVERY, 2002, 1 (09) :683-695