Measurement of single kidney contrast media clearance by multiphasic spiral computed tomography: preliminary results

被引:23
作者
Hackstein, N [1 ]
Puille, MF [1 ]
Bak, BH [1 ]
Scharwat, O [1 ]
Rau, WS [1 ]
机构
[1] Univ Giessen, Dept Diagnost Radiol, D-35385 Giessen, Germany
关键词
contrast media clearance; renal function; single kidney function; Patlak-Plot; computed tomography;
D O I
10.1016/S0720-048X(01)00323-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective. We present preliminary results of a new method (hereinafter called 'CT-clearance') to measure single kidney contrast media clearance by performing multiphasic helical CT of the kidneys. CT-clearance was calculated according to an extension of the Patlak-Plot. In contrast to prior investigators, who repeatedly measured a single slice, this method makes it possible to calculate single kidney clearance from at least three spiral CTs, utilizing the whole kidney volume. Methods. Spiral CT of the kidneys was performed unenhanced and about 30 and 100 s after administration of about 120 ml iopromide. Sum-density of the whole kidneys and aortic density was calculated from this data. Using this data, renal clearance of contrast media was calculated by CT-clearance in 29 patients. As reference, Serum-clearance was calculated in 24 patients by application of a modified one-exponential slope model. Information on the relative kidney function was gained by renal scintigraphy with Tc99m-MAG-3 or Tc99m-DMSA in 29 patients. Results. Linear regression analysis revealed a correlation coefficient of CT-clearance with Serum-clearance of r = 0.78 with Cl (CT) [ml/min] = 22.2 + 1.03 * Cl (serum), n = 24. Linear regression of the relative kidney function (rkf) of the right kidney calculated by CT-clearance compared to scintigraphy results provided a correlation coefficient r = 0.89 with rkf(CT)[%] = 18.6 + 0.58 * rkf(scintigraphy), n = 29. Conclusion. The obtained results of contrast media clearance measured by CT-clearance are in the physiological range of the parameter. Future studies should be performed to improve the methodology with the aim of higher accuracy. More specifically, better determination of the aortic density curve might improve the accuracy. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:201 / 208
页数:8
相关论文
共 12 条
[1]   The quantification of renal function with enhanced computed tomography [J].
Blomley, MJK ;
Dawson, P .
BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (827) :989-995
[2]   CONTRAST BOLUS DYNAMIC COMPUTED-TOMOGRAPHY FOR THE MEASUREMENT OF SOLID-ORGAN PERFUSION [J].
BLOMLEY, MJK ;
COULDEN, R ;
BUFKIN, C ;
LIPTON, MJ ;
DAWSON, P .
INVESTIGATIVE RADIOLOGY, 1993, 28 :S72-S77
[3]   VOLUME DETERMINATIONS USING COMPUTED-TOMOGRAPHY [J].
BREIMAN, RS ;
BECK, JW ;
KOROBKIN, M ;
GLENNY, R ;
AKWARI, OE ;
HEASTON, DK ;
MOORE, AV ;
RAM, PC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 138 (02) :329-333
[5]   IOHEXOL CLEARANCE FOR THE DETERMINATION OF GLOMERULAR-FILTRATION RATE IN CLINICAL-PRACTICE - EVIDENCE FOR A NEW GOLD STANDARD [J].
BROWN, SCW ;
OREILLY, PH .
JOURNAL OF UROLOGY, 1991, 146 (03) :675-679
[6]  
DAWSON P, 1993, INVEST RADIOL, V28, pS79
[7]   DYNAMIC CONTRAST BOLUS COMPUTED-TOMOGRAPHY FOR THE ASSESSMENT OF RENAL-FUNCTION [J].
DAWSON, P ;
PETERS, M .
INVESTIGATIVE RADIOLOGY, 1993, 28 (11) :1039-1042
[8]   TC-99M MAG3 FOR QUANTITATION OF DIFFERENTIAL RENAL-FUNCTION [J].
LLAMASELVIRA, JM ;
MARTINEZPAREDES, M ;
JIMENEZHEFFERNAN, A ;
SOPENA, R ;
REQUENA, MJ ;
GONZALEZ, FM ;
TORRES, M ;
MATEO, A .
NUCLEAR MEDICINE COMMUNICATIONS, 1989, 10 (10) :759-764
[9]   GRAPHICAL EVALUATION OF BLOOD-TO-BRAIN TRANSFER CONSTANTS FROM MULTIPLE-TIME UPTAKE DATA [J].
PATLAK, CS ;
BLASBERG, RG ;
FENSTERMACHER, JD .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1983, 3 (01) :1-7
[10]  
THOMSEN HS, 1987, ACTA RADIOL, V28, P653