Quantification of coronary plaque by 64-slice computed tomography: A comparison with quantitative intracoronary ultrasound

被引:75
作者
Otsuka, Masato [1 ,2 ]
Bruining, Nico [1 ]
Van Pelt, Niels C. [1 ,2 ]
Mollet, Nico R. [1 ,2 ]
Ligthart, Jurgen M. R. [1 ]
Vourvouri, Eleni [2 ]
Hamers, Ronald [1 ]
De Jaegere, Peter [1 ]
Wijns, William [3 ]
Van Domburg, Ron T. [1 ]
Stone, Gregg W. [4 ]
Veldhof, Susan [5 ]
Verheye, Stefan [6 ]
Dudek, Dariusz [7 ]
Serruys, Patrick W. [1 ]
Krestin, Gabriel P. [2 ]
De Feyter, Pim J. [1 ,2 ]
机构
[1] Erasmus MC, Dept Cardiol, Thoraxctr, Rotterdam, Netherlands
[2] Erasmus MC, Dept Radiol, Rotterdam, Netherlands
[3] Onze Lieve Vrouwe Ziekenhuis, Ctr Cardiovasc, Aalst, Belgium
[4] Columbia Univ, Med Ctr, New York, NY USA
[5] Abbott Vasc, Diegem, Belgium
[6] Middelheim Hosp, Antwerp, Belgium
[7] Jagiellonian Univ, Inst Cardiol, Krakow, Poland
关键词
atherosclerosis; computed tomography; coronary artery disease; imaging; plaque;
D O I
10.1097/RLI.0b013e31816a88a9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Noninvasive assessment of coronary atherosclerotic plaque may be useful for risk stratification and treatment of atherosclerosis. Materials and Methods: We studied 47 patients to investigate the accuracy of coronary plaque volume measurement acquired with 64-slice multislice computed tomography (MSCT), using newly developed quantification software, when compared with quantitative intracoronary ultrasound (QCU). Quantitative MSCT coronary angiography (QMSCT-CA) was performed to determine plaque volume for a matched region of interest (regional plaque burden) and in significant plaque defined as a plaque with >= 50% area obstruction in QCU, and compared with QCU. Dataset with image blurring and heavy calcification were excluded from analysis. Results: In 100 comparable regions of interest, regional plaque burden was highly correlated (coefficient r = 0.96; P < 0.001) between QCU and QMSCT-CA, but QMSCT-CA overestimated the plaque burden by a mean difference of 7 +/- 33 mm(3) (p = 0.03). In 76 significant plaques detected within the regions of interest, plaque volume determined by QMSCT-CA was highly correlated (r = 0.98; P < 0.001) with a slight underestimation of 2 +/- 17 mm(3) (p = not significant) when compared with QCU. Calcified and mixed plaque volume was slightly overestimated by 4 +/- 19 mm(3) (P = ns) and noncalcified plaque volume was significantly underestimated by 9 11 mm(3) (P < 0.001) with QMSCT-CA. Overall, the limits of agreement for plaque burden/volume measurement between QCU and QMSCT-CA were relatively large. Reproducibility for the measurements of regional plaque burden with QMSCT-CA was good, with a mean intraobserver and interobserver variability of 0% +/- 16% and 4% +/- 24%, respectively. Conclusions: Quantification of coronary plaque within selected proximal or middle coronary segments without image blurring and heavy calcification with 64-slice CT was moderately accurate with respect to intravascular ultrasound and demonstrated good reproducibility. Further improvement in CT resolution is required for more reliable measurement of coronary plaques using quantification software.
引用
收藏
页码:314 / 321
页数:8
相关论文
共 34 条
[1]   Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography - A segment-based comparison with intravascular ultrasound [J].
Achenbach, S ;
Moselewski, F ;
Ropers, D ;
Ferencik, M ;
Hoffmann, U ;
MacNeill, B ;
Pohle, K ;
Baum, U ;
Anders, K ;
Jang, I ;
Daniel, WG ;
Brady, TJ .
CIRCULATION, 2004, 109 (01) :14-17
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
Bruining N, 1998, CATHETER CARDIO DIAG, V43, P254, DOI 10.1002/(SICI)1097-0304(199803)43:3<254::AID-CCD3>3.0.CO
[4]  
2-8
[5]   Reproducible coronary plaque quantification by multislice computed tomography [J].
Bruining, Nico ;
Roelandt, Jos R. T. C. ;
Palumbo, Alessandro ;
La Grutta, Ludovico ;
Cademartiri, Filippo ;
de Feijter, Pirn J. ;
Mollet, Nico ;
van Domburg, Ron T. ;
Serruys, P. W. ;
Hamers, Ronald .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 69 (06) :857-865
[6]   Influence of a lipid-lowering therapy on calcified and noncalcified coronary plaques monitored by multislice detector computed tomography - Results of the New Age II pilot study [J].
Burgstahler, Christof ;
Reimann, Anja ;
Beck, Torsten ;
Kuettner, Axel ;
Baumann, Dorothee ;
Heuschmid, Martin ;
Brodoefel, Harald ;
Claussen, Claus D. ;
Kopp, Andreas F. ;
Schroeder, Stephen .
INVESTIGATIVE RADIOLOGY, 2007, 42 (03) :189-195
[7]   Influence of intracoronary attenuation on coronary plaque measurements using multislice computed tomography: observations in an ex vivo model of coronary computed tomography angiography [J].
Cademartiri, F ;
Mollet, NR ;
Runza, G ;
Bruining, N ;
Hamers, R ;
Somers, P ;
Knaapen, M ;
Verheye, S ;
Midiri, M ;
Krestin, GP ;
de Feyter, PJ .
EUROPEAN RADIOLOGY, 2005, 15 (07) :1426-1431
[8]   Retrospective image-based gating of intracoronary ultrasound images for improved quantitative analysis: The intelligate method [J].
de Winter, SA ;
Hamers, R ;
Degertekin, M ;
Tanabe, K ;
Lemos, PA ;
Serruys, PW ;
Roelandt, JRTC ;
Bruining, N .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 61 (01) :84-94
[9]   Coronary artery stenosis quantification using multislice computed tomography [J].
Dewey, Marc ;
Rutsch, Wofgang ;
Schnapauff, Dirk ;
Teige, Florian ;
Hamm, Bernd .
INVESTIGATIVE RADIOLOGY, 2007, 42 (02) :78-84
[10]   First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268