Influence of a lipid-lowering therapy on calcified and noncalcified coronary plaques monitored by multislice detector computed tomography - Results of the New Age II pilot study

被引:80
作者
Burgstahler, Christof
Reimann, Anja
Beck, Torsten
Kuettner, Axel
Baumann, Dorothee
Heuschmid, Martin
Brodoefel, Harald
Claussen, Claus D.
Kopp, Andreas F.
Schroeder, Stephen
机构
[1] Univ Tubingen, Dept Diagnost Radiol, D-72076 Tubingen, Germany
[2] Univ Tubingen, Dept Internal Med, Div Cardiol, D-72076 Tubingen, Germany
关键词
multislice detector computed tomography; lipid-lowering therapy; coronary artery disease; plaque imaging; New Age II Study; statins;
D O I
10.1097/01.rli.0000254408.96355.85
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Multislice detector computed tomography (MSCT) is an accurate noninvasive modality to detect and classify different stages of atherosclerosis. The aim of the New Age 11 Study was to detect coronary lesions in men without established coronary artery disease (CAD) but with a distinct cardiovascular risk profile. We also sought to assess the effect after I year of a lipid-lowering therapy (LLT) using 20 mg of atorvastatin. Methods: Forty-sixe male patients (mean, 61 +/- 10 years) with an elevated risk for CAD (PROCAM score > 3 quintile) without LLT were included. Native and contrast-enhanced scans were performed in all patients. A total of 27 of 46 patients received a follow-up scan (after 488 +/- 138 days). Coronary plaque burden (CPB) was assessed volumetrically. Results: The prevalence of CAD was 83% (38/46 patients), and 11% (5/46) without coronary calcifications still had noncalcified plaques. Total cholesterol and low-density lipoprotein cholesterol levels decreased significantly under LLT (225 +/- 41 mg/dL vs. 162 +/- 37 mg/dL, P > 0.0001 and 148 +/- 7 mg/dL vs. 88 +/- 5 mg/dL, P < 0.001, respectively). On follow-up, calcium score and CPB remained unchanged (Agatston score: 261 +/- 301 vs. 282 +/- 360; CPB: 0.149 +/- 0.108 vs. 0.128 +/- 0.075 mL, P > 0.05), whereas mean plaque volume of noncalcified plaques decreased significantly from 0.042 +/- 0.029 mL versus 0.030 +/- 0.014 mL (P < 0.05, mean reduction 0.012 +/- 0.017 mL or 24 +/- 13%). Conclusions: Stalin therapy led to a significant reduction of noncalcified plaque burden that was not reflected in calcium scoring or total plaque burden. This finding might explain the risk reduction after the initiation of statin therapy. Using multislice detector computed tomography, physicians have the potential to monitor medical treatment in patients with coronary atherosclerosis.
引用
收藏
页码:189 / 195
页数:7
相关论文
共 31 条
[1]   Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography - A segment-based comparison with intravascular ultrasound [J].
Achenbach, S ;
Moselewski, F ;
Ropers, D ;
Ferencik, M ;
Hoffmann, U ;
MacNeill, B ;
Pohle, K ;
Baum, U ;
Anders, K ;
Jang, I ;
Daniel, WG ;
Brady, TJ .
CIRCULATION, 2004, 109 (01) :14-17
[2]   Coronary calcification, coronary disease risk factors, C-reactive protein, and atherosclerotic cardiovascular disease events - The St. Francis Heart Study [J].
Arad, Y ;
Goodman, KJ ;
Roth, M ;
Newstein, D ;
Guerci, AD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (01) :158-165
[3]   THE PROSPECTIVE CARDIOVASCULAR MUNSTER STUDY - PREVALENCE AND PROGNOSTIC-SIGNIFICANCE OF HYPERLIPIDEMIA IN MEN WITH SYSTEMIC HYPERTENSION [J].
ASSMANN, G ;
SCHULTE, H .
AMERICAN JOURNAL OF CARDIOLOGY, 1987, 59 (14) :G9-G17
[4]   Comparison of three generations of electron beam tomography on image noise and reproducibility, a phantom study [J].
Chau, Alex ;
Gopal, Ambarish ;
Mao, SongShou ;
Tseng, Philip H. ;
Fischer, Hans ;
Budoff, Matthew J. .
INVESTIGATIVE RADIOLOGY, 2006, 41 (06) :522-526
[5]   Image reconstruction and image quality evaluation for a 64-slice CT scanner with z-flying focal spot [J].
Flohr, TG ;
Stierstorfer, K ;
Ulzheimer, S ;
Bruder, H ;
Primak, AN ;
McCollough, CH .
MEDICAL PHYSICS, 2005, 32 (08) :2536-2547
[6]   Microcirculatory efficacy of topical treatment with Aescin plus essential phospholipids gel on transcutaneous Po2 in venous insufficiency [J].
Cesarone, MR ;
Belcaro, G ;
Ippolito, E ;
Ricci, A ;
Ruffini, M ;
Dugall, M .
ANGIOLOGY, 2004, 55 :S7-S10
[7]   Effect of acquisition technique on radiation dose and image quality in multidetector row computed tomography coronary angiography with submillimeter collimation [J].
Gerber, TC ;
Stratmann, BP ;
Kuzo, RS ;
Kantor, B ;
Morin, RL .
INVESTIGATIVE RADIOLOGY, 2005, 40 (08) :556-563
[8]   Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: Influence of heart rate on image quality and stenosis detection [J].
Giesler, T ;
Baum, U ;
Ropers, D ;
Ulzheimer, S ;
Wenkel, E ;
Mennicke, M ;
Bautz, W ;
Kalender, WA ;
Daniel, WG ;
Achenbach, S .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (04) :911-916
[9]   Prevalence of noncalcified coronary plaques by 64-slice computed tomography in patients intermediate risk for significant with an coronary artery disease [J].
Hausleiter, Joerg ;
Meyer, Tanja ;
Hadamitzky, Martin ;
Kastrati, Adnan ;
Martinoff, Stefan ;
Schoemig, Albert .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (02) :312-318
[10]   Non-invasive characterisation of coronary lesion morphology and composition by multislice CT: first results in comparison with intracoronary ultrasound [J].
Kopp, AF ;
Schroeder, S ;
Baumbach, A ;
Kuettner, A ;
Georg, C ;
Ohnesorge, B ;
Heuschmid, M ;
Kuzo, R ;
Claussen, CD .
EUROPEAN RADIOLOGY, 2001, 11 (09) :1607-1611