Alterations in normal liver doses due to organ motion

被引:63
作者
Rosu, M [1 ]
Dawson, LA [1 ]
Balter, JM [1 ]
McShan, DL [1 ]
Lawrence, TS [1 ]
Haken, RKT [1 ]
机构
[1] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2003年 / 57卷 / 05期
关键词
geometric convolution; treatment planning; uncertainties; target coverage;
D O I
10.1016/j.ijrobp.2003.08.025
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To assess the clinical significance of differences between treatment planning calculations based on static computed tomography (CT) and more realistic predictions of the actual delivered dose to intrahepatic lesions by a geometric convolution approach that accounts for random setup variations and breathing-induced organ motion. Methods and Materials: We recalculated target and normal liver doses for 40 patients previously treated on a conformal therapy dose escalation protocol to include the effect of setup uncertainties and liver motion due to patient breathing. Initial three-dimensional (3D) dose calculations based on pretreatment CT scans taken with voluntary breath-hold at normal exhalation were convolved with 3D anisotropic probability distribution functions reflecting population measurements of position setup variation. The convolution also included a distribution function (one-dimensional, inferior-superior direction only) representing the asymmetric temporal pattern (biased toward exhalation, based on population measurements) of a typical breathing cycle, scaled in amplitude for each patient. Results: After convolution, the minimum clinical target volume (CTV) dose met or exceeded the minimum planning target volume (PTV) dose from the static plan in all but one case, indicating adequate PTV design. However, clinically relevant and statistically significant increases (decreases) in liver normal tissue complication probability (NTCP) from values computed for the static cases occured for tumors located toward the bottom (top) of the liver, as predicted for these patients scanned at exhalation. The change in liver NTCP (from a nominal 20%) ranged from +12.0% to -11.7% (average magnitude change 3.9% [sigma = 3.3%]). Changes in prescription dose required to restore the original 20% NTCP ranged from -3.7 Gy to +7.9 Gy (average magnitude change 1.9 Gy [sigma = 1.9 Gy]). Conclusion: Although the PTV concept can ensure adequate CTV coverage, the doses to normal liver are incorrectly modeled without including patient-related geometric uncertainties. (C) 2003 Elsevier Inc.
引用
收藏
页码:1472 / 1479
页数:8
相关论文
共 30 条
[1]  
[Anonymous], 1993, 50 ICRU
[2]   Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging [J].
Balter, JM ;
Lam, KL ;
McGinn, CJ ;
Lawrence, TS ;
Ten Haken, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (04) :939-943
[3]   Daily targeting of intrahepatic tumors for radiotherapy [J].
Balter, JM ;
Brock, KK ;
Litzenberg, DW ;
McShan, DL ;
Lawrence, TS ;
Ten Haken, R ;
McGinn, CJ ;
Lam, KL ;
Dawson, LA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (01) :266-271
[4]   Inclusion of organ deformation in dose calculations [J].
Brock, KK ;
McShan, DL ;
Ten Haken, RK ;
Hollister, SJ ;
Dawson, LA ;
Balter, JM .
MEDICAL PHYSICS, 2003, 30 (03) :290-295
[5]   Technical note: Creating a four-dimensional model of the liver using finite element analysis [J].
Brock, KK ;
Hollister, SJ ;
Dawson, LA ;
Balter, JM .
MEDICAL PHYSICS, 2002, 29 (07) :1403-1405
[6]   A fluence convolution method to account for respiratory motion in three-dimensional dose calculations of the liver: A Monte Carlo study [J].
Chetty, IJ ;
Rosu, M ;
Tyagi, N ;
Marsh, LH ;
McShan, DL ;
Balter, JM ;
Fraass, BA ;
Ten Haken, RK .
MEDICAL PHYSICS, 2003, 30 (07) :1776-1780
[7]   The reproducibility of organ position using active breathing control (ABC) during liver radiotherapy [J].
Dawson, LA ;
Brock, KK ;
Kazanjian, S ;
Fitch, D ;
McGinn, CJ ;
Lawrence, TS ;
Ten Haken, RK ;
Balter, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (05) :1410-1421
[8]   Partial irradiation of the liver [J].
Dawson, LA ;
Ten Haken, RK ;
Lawrence, TS .
SEMINARS IN RADIATION ONCOLOGY, 2001, 11 (03) :240-246
[9]   Escalated focal liver radiation and concurrent hepatic artery fluorodeoxyuridine for unresectable intrahepatic malignancies [J].
Dawson, LA ;
McGinn, CJ ;
Normolle, D ;
Ten Haken, RK ;
Walker, S ;
Ensminger, W ;
Lawrence, TS .
JOURNAL OF CLINICAL ONCOLOGY, 2000, 18 (11) :2210-2218
[10]  
Dawson LA, 2002, INT J RADIAT ONCOL, V53, P810, DOI 10.1016/S0360-3016(02)02846-8