Technical note: Creating a four-dimensional model of the liver using finite element analysis

被引:60
作者
Brock, KK [1 ]
Hollister, SJ [1 ]
Dawson, LA [1 ]
Balter, JM [1 ]
机构
[1] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
关键词
organ deformation; organ motion; mechanical modeling;
D O I
10.1118/1.1485055
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Finite element analysis and two liver CT scans were used to construct a four-dimensional (41)) model of the liver during breathing. A linear elastic, small deformation mechanical model was applied to one patient to obtain intermediate organ position and shape between exhale and inhale. Known transformations between anatomically defined subsections of the exhale and inhale liver surfaces were applied as constraints to the exhale CT liver model. Intermediate states were then calculated and time weighted to determine a 4D model of the liver as it deforms during the breathing cycle. This model can be used to calculate a more accurate dose distribution during radiotherapy. (C) 2002 American Association of Physicists in Medicine.
引用
收藏
页码:1403 / 1405
页数:3
相关论文
共 8 条
[1]
Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging [J].
Balter, JM ;
Lam, KL ;
McGinn, CJ ;
Lawrence, TS ;
Ten Haken, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (04) :939-943
[2]
Daily targeting of intrahepatic tumors for radiotherapy [J].
Balter, JM ;
Brock, KK ;
Litzenberg, DW ;
McShan, DL ;
Lawrence, TS ;
Ten Haken, R ;
McGinn, CJ ;
Lam, KL ;
Dawson, LA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (01) :266-271
[3]
Tissue characterization using magnetic resonance elastography: preliminary results [J].
Kruse, SA ;
Smith, JA ;
Lawrence, AJ ;
Dresner, MA ;
Manduca, A ;
Greenleaf, JF ;
Ehman, RL .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (06) :1579-1590
[4]
Constitutive modelling of abdominal organs [J].
Miller, K .
JOURNAL OF BIOMECHANICS, 2000, 33 (03) :367-373
[5]
Detection of lung tumor movement in real-time tumor-tracking radiotherapy [J].
Shimizu, S ;
Shirato, H ;
Ogura, S ;
Akita-Dosaka, H ;
Kitamura, K ;
Nishioka, T ;
Kagei, K ;
Nishimura, M ;
Miyasaka, K .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (02) :304-310
[6]
THOMPSON JS, 1990, THOMPSON CORE TXB AN
[7]
Determining parameters for respiration-gated radiotherapy [J].
Vedam, SS ;
Keall, PJ ;
Kini, VR ;
Mohan, R .
MEDICAL PHYSICS, 2001, 28 (10) :2139-2146
[8]
Organ/patient geometric variation in external beam radiotherapy and its effects [J].
Yan, D ;
Lockman, D .
MEDICAL PHYSICS, 2001, 28 (04) :593-602