X-ray holographic microscopy by means of photoresist recording and atomic-force microscope readout

被引:50
作者
Lindaas, S [1 ]
Howells, H [1 ]
Jacobsen, C [1 ]
Kalinovsky, A [1 ]
机构
[1] SUNY STONY BROOK, DEPT PHYS, STONY BROOK, NY 11794 USA
关键词
D O I
10.1364/JOSAA.13.001788
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We have reconstructed in-line (or Gabor) x-ray holograms at 40-50-nm resolution from a complex biological specimen. The holograms were recorded as a relief pattern on photoresist with use of 1.89-nm, soft, x rays from the X1A undulator beam line at the National Synchrotron Light Source at Brookhaven National Laboratory. We have improved the resolution and the fidelity and simplified the experiment compared with earlier work by employing a special atomic-force microscope to examine and digitize the holograms. Following digitization the holograms were reconstructed numerically, allowing both the absorptive and phase-shifting properties of the reconstructed objected to be mapped. A comparison of the reconstructed images with images obtained from holographic technique. The method offers promise as a technique for soft-x-ray microscopy and diffraction tomography of dry and frozen hydrated specimens and for microscopy with pulsed x-ray sources. (C) 1996 Optical Society of America.
引用
收藏
页码:1788 / 1800
页数:13
相关论文
共 59 条
[51]   X-RAY MICROSCOPY OF BIOLOGICAL OBJECTS WITH CARBON-K-ALPHA AND WITH SYNCHROTRON RADIATION [J].
SPILLER, E ;
FEDER, R ;
TOPALIAN, J ;
EASTMAN, D ;
GUDAT, W ;
SAYRE, D .
SCIENCE, 1976, 191 (4232) :1172-1174
[52]  
Stead A D, 1995, J Xray Sci Technol, V5, P52, DOI [10.1016/S0895-3996(05)80012-6, 10.3233/XST-1995-5105]
[53]  
STEAD AD, 1992, SOFT XRAY MICROSCOPY, V1741, P351
[54]   DEMONSTRATION OF X-RAY HOLOGRAPHY WITH AN X-RAY LASER [J].
TREBES, JE ;
BROWN, SB ;
CAMPBELL, EM ;
MATTHEWS, DL ;
NILSON, DG ;
STONE, GF ;
WHELAN, DA .
SCIENCE, 1987, 238 (4826) :517-519
[55]   FRAUNHOFER HOLOGRAPHY APPLIED TO PARTICLE-SIZE ANALYSIS - REASSESSMENT [J].
TYLER, GA ;
THOMPSON, BJ .
OPTICA ACTA, 1976, 23 (09) :685-700
[56]   MEASUREMENTS OF WET METAPHASE CHROMOSOMES IN THE SCANNING-TRANSMISSION X-RAY MICROSCOPE [J].
WILLIAMS, S ;
ZHANG, X ;
JACOBSEN, C ;
KIRZ, J ;
LINDAAS, S ;
VANTHOF, J ;
LAMM, SS .
JOURNAL OF MICROSCOPY-OXFORD, 1993, 170 :155-165
[57]  
Williams S., 1992, Proceedings of the SPIE - The International Society for Optical Engineering, V1741, P318
[58]   The linac coherent light source (LCLS): A fourth-generation light source using the SLAG linac [J].
Winick, H .
JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1995, 75 :1-8
[59]   EXPOSURE STRATEGIES FOR POLYMETHYL METHACRYLATE FROM IN-SITU X-RAY-ABSORPTION NEAR-EDGE STRUCTURE SPECTROSCOPY [J].
ZHANG, X ;
JACOBSEN, C ;
LINDAAS, S ;
WILLIAMS, S .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1995, 13 (04) :1477-1483