Evaluation of ultrasound-based prostate localization for image-guided radiotherapy

被引:192
作者
Langen, KM
Pouliot, J
Anezinos, C
Aubin, M
Gottschalk, AR
Hsu, IC
Lowther, D
Liu, YM
Shinohara, K
Verhey, LJ
Weinberg, V
Roach, M
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, Sch Med, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Dept Urol, Sch Med, San Francisco, CA 94143 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2003年 / 57卷 / 03期
关键词
prostate cancer; organ motion; daily prostate localization;
D O I
10.1016/S0360-3016(03)00633-3
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate the use of the ultrasound-based BAT system for daily prostate alignment. Materials and Methods: Prostate alignments using the BAT system were compared with alignments using radiographic images of implanted radiopaque markers. The latter alignments were used as a reference. The difference between the BAT and marker alignments represents the displacements that would remain if the alignments were done using ultrasonography. The inter-user variability of the contour alignment process was assessed. Results: On the basis of the marker alignments, the initial displacement of the prostate in the AP, superoinferior, and lateral direction was -0.9 +/- 3.9, 0.1 +/- 3.9, and 0.2 +/- 3.4 mm respectively. The directed differences between the BAT and marker alignments in the respective directions were 0.2 +/- 3.7, 2.7 +/- 3.9, and 1.6 +/- 3.1 mm. The occurrence of displacements 2:5 mm was reduced by a factor of two in the AP direction after the BAT system was used. Among eight users, the average range of couch shifts due to contour alignment variability was 7, 7, and 5 mm in the antero-posterior (AP), superoinferior, and lateral direction, respectively. Conclusion: In our study, the BAT alignments were systematically different from the marker alignments in the superoinferior, and lateral directions. The remaining random variability of the prostate position after the ultrasound-based alignment was similar to the initial variability. However, the occurrence of displacements 2:5 mm was reduced in the AP direction. The inter-user variation of the contour alignment process was significant. (C) 2003 Elsevier Inc.
引用
收藏
页码:635 / 644
页数:10
相关论文
共 16 条
[11]   Combined error of patient positioning variability and prostate motion uncertainty in 3D conformal radiotherapy of localized prostate cancer [J].
Rudat, V ;
Schraube, P ;
Oetzel, D ;
Zierhut, D ;
Flentje, M ;
Wannenmacher, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (05) :1027-1034
[12]   Initial experience with ultrasound localization for positioning prostate cancer patients for external beam radiotherapy [J].
Serago, CF ;
Chungbin, SJ ;
Buskirk, SJ ;
Ezzell, GA ;
Collie, AC ;
Vora, SA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05) :1130-1138
[13]   Variation of clinical target volume definition in three-dimensional conformal radiation therapy for prostate cancer [J].
Valicenti, RK ;
Sweet, JW ;
Hauck, WW ;
Hudes, RS ;
Lee, T ;
Dicker, AP ;
Waterman, FM ;
Anne, PR ;
Corn, BW ;
Galvin, JM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 44 (04) :931-935
[14]  
Van den Heuvel F., 2002, International Journal of Radiation Oncology Biology Physics, V54, P178, DOI 10.1016/S0360-3016(02)03367-9
[15]  
Verhey, 1995, Semin Radiat Oncol, V5, P100, DOI 10.1016/S1053-4296(95)80004-2
[16]   Electronic portal imaging device detection of radioopaque markers for the evaluation of prostate position during megavoltage irradiation: A clinical study [J].
Vigneault, E ;
Pouliot, J ;
Laverdiere, J ;
Roy, J ;
Dorion, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (01) :205-212