Initial experience with ultrasound localization for positioning prostate cancer patients for external beam radiotherapy

被引:127
作者
Serago, CF
Chungbin, SJ
Buskirk, SJ
Ezzell, GA
Collie, AC
Vora, SA
机构
[1] Mayo Clin, Dept Radiat Oncol, Jacksonville, FL 32224 USA
[2] Mayo Clin, Dept Radiat Oncol, Scottsdale, AZ USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2002年 / 53卷 / 05期
关键词
prostate cancer; quality assurance; radiotherapy; ultrasound positioning system;
D O I
10.1016/S0360-3016(02)02826-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Transabdominal ultrasound localization of the prostate gland and its immediate surrounding anatomy has been used to guide the positioning of patients for the treatment of prostate cancer. This process was evaluated in terms of (1) the reproducibility of the ultrasound measurement; (2) a comparison of patient position between ultrasound localization and skin marks determined from a CT treatment planning scan; (3) the predictive indicators of patient anatomy not well suited for ultrasound localization; (4) the measurement of prostate organ displacement resulting from ultrasound probe pressure; and (5) quality assurance measures. Methods and Materials: The reproducibility of the ultrasound positioning process was evaluated for same-day repeat positioning by the same ultrasound operator (22 patients) and for measurements made by 2 different operators (38 patients). Differences between conventional patient positioning (CT localization with skin markings) and ultrasound-based positioning were determined for 38 patients. The pelvic anatomy was evaluated for 34 patients with pretreatment CT scans to identify predictors of poor ultrasound image quality. The displacement of the prostate resulting from pressure of the ultrasound probe was measured for 16 patients with duplicate CT scans with and without a simulated probe. Finally, daily, monthly, and semiannual quality assurance tests were evaluated. Results: Self-verification tests of ultrasound positioning indicated a shift of <3 min in approximately 95% of cases. Interoperator tests indicated shifts of <3 mm in approximately 80-90% of cases. The mean difference in patient positioning between conventional and ultrasound localization for lateral shifts was 0.3 mm (SD 2.5): vertical, 1.3 mm (SD 4.7 mm) and longitudinal, 1.0 mm (SD 5.1). However, on a single day, the differences were >10 mm in 1.5% of lateral shifts, 7% of longitudinal shifts, and 7% of vertical shifts. The depth to the isocenter, thickness of tissue overlying the bladder, and position of the prostate relative to the pubic symphysis, but not the bladder volume, were significant predictive indicators of poor ultrasound imaging. The pressure of the ultrasound probe displaced the prostate in 7 of the 16 patients by an average distance of 3.1 mm; 9 patients (56%) showed no displacement. Finally, the quality assurance tests detected ultrasound equipment defects. Conclusion: The ultrasound positioning system is reproducible and may indicate the need for significant positioning moves. Factors that predict poor image quality are the depth to the isocenter, thickness of tissue overlying the bladder, and position of the prostate relative to the pubic symphysis. The prostate gland may be displaced a small amount by the pressure of the ultrasound probe. A quaility assurance program is necessary, to detect ultrasound equipment defects that could result in patient alignment errors. (C) 2002 Elsevier Science Inc.
引用
收藏
页码:1130 / 1138
页数:9
相关论文
共 26 条
[1]   Portal imaging for evaluation of daily on-line setup errors and off-line organ motion during conformal irradiation of carcinoma of the prostate [J].
Alasti, H ;
Petric, MP ;
Catton, CN ;
Warde, PR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (03) :869-884
[2]   MEASUREMENT OF PROSTATE MOVEMENT OVER THE COURSE OF ROUTINE RADIOTHERAPY USING IMPLANTED MARKERS [J].
BALTER, JM ;
SANDLER, HM ;
LAM, K ;
BREE, RL ;
LICHTER, AS ;
TENHAKEN, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01) :113-118
[3]   LATE RECTAL BLEEDING FOLLOWING COMBINED X-RAY AND PROTON HIGH-DOSE IRRADIATION FOR PATIENTS WITH STAGES T3-T4 PROSTATE CARCINOMA [J].
BENK, VA ;
ADAMS, JA ;
SHIPLEY, WU ;
URIE, MM ;
MCMANUS, PL ;
EFIRD, JT ;
WILLETT, CG ;
GOITEIN, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 26 (03) :551-557
[4]   High-precision conformal radiotherapy (HPCRT) of prostate cancer -: A new technique for exact positioning of the prostate at the time of treatment [J].
Bergström, P ;
Löfroth, PO ;
Widmark, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (02) :305-311
[5]   Dose escalation with 3D conformal treatment: Five year outcomes, treatment optimization, and future directions [J].
Hanks, GE ;
Hanlon, AL ;
Schultheiss, TE ;
Pinover, WH ;
Movsas, B ;
Epstein, BE ;
Hunt, MA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (03) :501-510
[6]   Conformal irradiation of the prostate: Estimating long-term rectal bleeding risk using dose-volume histograms [J].
Hartford, AC ;
Niemierko, A ;
Adams, JA ;
Urie, MM ;
Shipley, WU .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (03) :721-730
[7]  
Horwitz EM, 2001, CANCER, V92, P1281, DOI 10.1002/1097-0142(20010901)92:5<1281::AID-CNCR1449>3.0.CO
[8]  
2-9
[9]  
International Commission in Radiation Units and Measurements, 1999, 62 ICRU
[10]  
International Commission in Radiation Units and Measurements, 1993, 50 ICRU