Portal imaging for evaluation of daily on-line setup errors and off-line organ motion during conformal irradiation of carcinoma of the prostate

被引:141
作者
Alasti, H
Petric, MP
Catton, CN
Warde, PR
机构
[1] Princess Margaret Hosp, Dept Radiat Phys, Toronto, ON M4X 1K9, Canada
[2] Princess Margaret Hosp, Dept Radiat Oncol, Toronto, ON M4X 1K9, Canada
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2001年 / 49卷 / 03期
关键词
prostate motion; patient repositioning; planning target volume; on-line portal imaging; conformal radiotherapy;
D O I
10.1016/S0360-3016(00)01446-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To use portal imaging to measure daily on-line setup error and off-line prostatic motion in patients treated with conformal radiotherapy to determine an optimum planning target volume (PTV) margin incorporating both setup error and organ motion, Results: A total of 2549 portal images from 33 patients were acquired over the course of the study. Of these patients, 23 were analyzed for setup errors while the remaining 10 were analyzed for prostatic motion, Setup errors were characterized by standard deviations of 1.8 mm in the anterior-posterior (AP) direction and 1.4 mm in the superior-inferior (SI) direction, Displacements due to prostatic motion, with standard deviations of 5.8 mm AP and 3.3 mm SI, were found to be more significant than setup errors, Conclusions: Taking into account both setup errors and target organ motion, optimum PTV margins to ensure 95% coverage are 10.0 mm AP and 5.9 mm SI. The portal imaging protocol established in this study allows radiation therapists to accept or adjust a treatment setup based upon daily on-line image matching results. The successful localization of radiopaque fiducial markers on a significant number of portal images acquired in the study gives hope that more accurate on-line targeting verification mag soon be possible through the visualization of the prostate itself as opposed to the surrounding bony structures of the pelvis, (C) 2001 Elsevier Science Inc.
引用
收藏
页码:869 / 884
页数:16
相关论文
共 38 条
[1]  
[Anonymous], 1993, ICRU Report 50
[2]   Prostate target volume variations during a course of radiotherapy [J].
Antolak, JA ;
Rosen, II ;
Childress, CH ;
Zagars, GK ;
Pollack, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (03) :661-672
[3]   Initial performance evaluation of an indirect-detection, active matrix flat-panel imager (AMFPI) prototype for megavoltage imaging [J].
Antonuk, LE ;
El-Mohri, Y ;
Huang, WD ;
Jee, KW ;
Siewerdsen, JH ;
Maolinbay, M ;
Scarpine, VE ;
Sandler, H ;
Yorkston, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (02) :437-454
[4]   Automated localization of the prostate at the time of treatment using implanted radiopaque markers: Technical feasibility [J].
Balter, JM ;
Lam, KL ;
Sandler, HM ;
Littles, JF ;
Bree, RL ;
TenHaken, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1281-1286
[5]   ONLINE REPOSITIONING DURING TREATMENT OF THE PROSTATE - A STUDY OF POTENTIAL LIMITS AND GAINS [J].
BALTER, JM ;
CHEN, GTY ;
PELIZZARI, CA ;
KRISHNASAMY, S ;
RUBIN, S ;
VIJAYAKUMAR, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (01) :137-143
[6]   MEASUREMENT OF PROSTATE MOVEMENT OVER THE COURSE OF ROUTINE RADIOTHERAPY USING IMPLANTED MARKERS [J].
BALTER, JM ;
SANDLER, HM ;
LAM, K ;
BREE, RL ;
LICHTER, AS ;
TENHAKEN, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01) :113-118
[7]   Target margins for random geometrical treatment uncertainties in conformal radiotherapy [J].
Bel, A ;
vanHerk, M ;
Lebesque, JV .
MEDICAL PHYSICS, 1996, 23 (09) :1537-1545
[8]   High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging [J].
Bel, A ;
Vos, PH ;
Rodrigus, PTR ;
Creutzberg, CL ;
Visser, AG ;
Stroom, JC ;
Lebesque, JV .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (02) :321-332
[9]   High-precision conformal radiotherapy (HPCRT) of prostate cancer -: A new technique for exact positioning of the prostate at the time of treatment [J].
Bergström, P ;
Löfroth, PO ;
Widmark, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (02) :305-311
[10]  
CATTON C, 1998, INT J RAD ONCOL B S1, V42, P216