Portal imaging for evaluation of daily on-line setup errors and off-line organ motion during conformal irradiation of carcinoma of the prostate

被引:141
作者
Alasti, H
Petric, MP
Catton, CN
Warde, PR
机构
[1] Princess Margaret Hosp, Dept Radiat Phys, Toronto, ON M4X 1K9, Canada
[2] Princess Margaret Hosp, Dept Radiat Oncol, Toronto, ON M4X 1K9, Canada
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2001年 / 49卷 / 03期
关键词
prostate motion; patient repositioning; planning target volume; on-line portal imaging; conformal radiotherapy;
D O I
10.1016/S0360-3016(00)01446-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To use portal imaging to measure daily on-line setup error and off-line prostatic motion in patients treated with conformal radiotherapy to determine an optimum planning target volume (PTV) margin incorporating both setup error and organ motion, Results: A total of 2549 portal images from 33 patients were acquired over the course of the study. Of these patients, 23 were analyzed for setup errors while the remaining 10 were analyzed for prostatic motion, Setup errors were characterized by standard deviations of 1.8 mm in the anterior-posterior (AP) direction and 1.4 mm in the superior-inferior (SI) direction, Displacements due to prostatic motion, with standard deviations of 5.8 mm AP and 3.3 mm SI, were found to be more significant than setup errors, Conclusions: Taking into account both setup errors and target organ motion, optimum PTV margins to ensure 95% coverage are 10.0 mm AP and 5.9 mm SI. The portal imaging protocol established in this study allows radiation therapists to accept or adjust a treatment setup based upon daily on-line image matching results. The successful localization of radiopaque fiducial markers on a significant number of portal images acquired in the study gives hope that more accurate on-line targeting verification mag soon be possible through the visualization of the prostate itself as opposed to the surrounding bony structures of the pelvis, (C) 2001 Elsevier Science Inc.
引用
收藏
页码:869 / 884
页数:16
相关论文
共 38 条
[21]   Potential and role of a prototype amorphous silicon array electronic portal imaging device in breathing synchronized radiotherapy [J].
Kubo, HD ;
Shapiro, EG ;
Seppi, EJ .
MEDICAL PHYSICS, 1999, 26 (11) :2410-2414
[22]  
Kutcher, 1995, Semin Radiat Oncol, V5, P134, DOI 10.1016/S1053-4296(95)80006-9
[23]   Cancer statistics, 1998 [J].
Landis, SH ;
Murray, T ;
Bolden, S ;
Wingo, PA .
CA-A CANCER JOURNAL FOR CLINICIANS, 1998, 48 (01) :6-+
[24]   Variation in prostate position quantitation and implications for three-dimensional conformal treatment planning [J].
Melian, E ;
Mageras, GS ;
Fuks, Z ;
Leibel, SA ;
Niehaus, A ;
Lorant, H ;
Zelefsky, M ;
Baldwin, B ;
Kutcher, GJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (01) :73-81
[25]   Portal imaging protocol for radical dose-escalated radiotherapy treatment of prostate cancer [J].
Mubata, CD ;
Bidmead, AM ;
Ellingham, LM ;
Thompson, V ;
Dearnaley, DP .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (01) :221-231
[26]   CORRELATION OF RADIOTHERAPEUTIC PARAMETERS AND TREATMENT RELATED MORBIDITY - ANALYSIS OF RTOG STUDY 77-06 [J].
PILEPICH, MV ;
ASBELL, SO ;
KRALL, JM ;
BAERWALD, WH ;
SAUSE, WT ;
RUBIN, P ;
EMAMI, BN ;
PIDCOCK, GM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (07) :1007-1012
[27]   Long-term survival after radiotherapy alone: Radiation therapy oncology group prostate cancer trials [J].
Roach, M ;
Lu, JD ;
Pilepich, MV ;
Asbell, SO ;
Mohiuddin, M ;
Terry, R ;
Grignon, D .
JOURNAL OF UROLOGY, 1999, 161 (03) :864-868
[28]   Evaluation of changes in the size and location of the prostate, seminal vesicles, bladder, and rectum during a course of external beam radiation therapy [J].
Roeske, JC ;
Forman, JD ;
Mesina, CF ;
He, T ;
Pelizzari, CA ;
Fontenla, E ;
Vijayakumar, S ;
Chen, GTY .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1321-1329
[29]   IMMOBILIZATION IMPROVES THE REPRODUCIBILITY OF PATIENT POSITIONING DURING 6-FIELD CONFORMAL RADIATION-THERAPY FOR PROSTATE CARCINOMA [J].
ROSENTHAL, SA ;
GOLDSMITH, BJ ;
DOGGETT, EC ;
PICKETT, B ;
YUO, HS ;
SOFFEN, EM ;
STERN, RL ;
RYU, JK ;
ROACH, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (04) :921-926
[30]   Combined error of patient positioning variability and prostate motion uncertainty in 3D conformal radiotherapy of localized prostate cancer [J].
Rudat, V ;
Schraube, P ;
Oetzel, D ;
Zierhut, D ;
Flentje, M ;
Wannenmacher, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (05) :1027-1034