A hydrogen peroxide sensor based on a horseradish peroxidase/polyaniline/carboxy-functionalized multiwalled carbon nanotube modified gold electrode

被引:53
作者
Hua, Mu-Yi [1 ,2 ]
Lin, Yu-Chen [1 ,2 ]
Tsai, Rung-Ywan [3 ]
Chen, Hsiao-Chien [1 ,2 ]
Liu, Yin-Chih [1 ,2 ]
机构
[1] Chang Gung Univ, Green Res Ctr, Dept Chem & Mat Engn, Tao Yuan 33302, Taiwan
[2] Chang Gung Univ, Biosensor Grp, Biomed Engn Res Ctr, Tao Yuan 33302, Taiwan
[3] Ind Technol Res Inst, Elect & Optoelect Res Labs, Hsinchu 31040, Taiwan
关键词
H2O2; sensor; Horseradish peroxidase; Carboxy-functionalized multiwalled carbon nanotubes; Polyaniline; GLUCOSE BIOSENSOR; CONDUCTING-POLYMER; DIRECT ELECTROCHEMISTRY; AMPEROMETRIC BIOSENSOR; ENZYME IMMOBILIZATION; DOPED POLYANILINE; COMPOSITE; ACID; OXIDASE; FILM;
D O I
10.1016/j.electacta.2011.08.043
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
We have developed a polyaniline/carboxy-functionalized multiwalled carbon nanotube (PAn/MWCNTCOOH) nanocomposite by blending the emeraldine base form of polyaniline (PAn) and carboxy-functionalized multiwalled carbon nanotubes (MWCNT) in dried dimethyl sulfoxide (DMSO) at room temperature. The conductivity of the resulting PAn/MWCNTCOOH was 3.6 x 10(-3)S cm(-1), mainly as a result of the protonation of the PAn with the carboxyl group and the radical cations of the MWCNT fragments. Horseradish peroxidase (HRP) was immobilized within the PAn/MWCNTCOOH nanocomposite modified Au (PAn/MWCNTCOOH/Au) electrode to form HRP/PAn/MWCNTCOOH/Au for use as a hydrogen peroxide (H2O2) sensor. The adsorption between the negatively charged PAn/MWCNTCOOH nanocomposite and the positively charged HRP resulted in a very good sensitivity to H2O2 and an increased electrochemically catalytical current during cyclic voltammetry. The HRP/PAn/MWCNTCOOH/Au electrode exhibited a broad linear response range for H2O2 concentrations (86 mu M-10 mM). This sensor exhibited good sensitivity (194.9 mu A mM(-1) cm(-2)), a fast response time (2.9s), and good reproducibility and stability at an applied potential of -0.35V. The construction of the enzymatic sensor demonstrated the potential application of PAn/MWCNTCOOH nanocomposites for the detection of H2O2 with high performance and excellent stability. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:9488 / 9495
页数:8
相关论文
共 58 条
[11]   Fabrication of polyaniline/carbon nanotube composite modified electrode and its electrocatalytic property to the reduction of nitrite [J].
Guo, ML ;
Chen, JH ;
Li, J ;
Tao, B ;
Yao, SZ .
ANALYTICA CHIMICA ACTA, 2005, 532 (01) :71-77
[12]  
Hamon MA, 1999, ADV MATER, V11, P834, DOI 10.1002/(SICI)1521-4095(199907)11:10<834::AID-ADMA834>3.0.CO
[13]  
2-R
[14]   Acid doping of polyaniline: Spectroscopic and electrochemical studies [J].
Hatchett, DW ;
Josowicz, M ;
Janata, J .
JOURNAL OF PHYSICAL CHEMISTRY B, 1999, 103 (50) :10992-10998
[15]  
Hirsch A, 2002, ANGEW CHEM INT EDIT, V41, P1853, DOI 10.1002/1521-3773(20020603)41:11<1853::AID-ANIE1853>3.0.CO
[16]  
2-N
[17]   The intrinsic redox reactions of polyamic acid derivatives and their application in hydrogen peroxide sensor [J].
Hua, Mu-Yi ;
Chen, Hsiao-Chien ;
Chuang, Cheng-Keng ;
Tsai, Rung-Ywan ;
Jeng, Jyh-Long ;
Yang, Hung-Wei ;
Chern, Yaw-Terng .
BIOMATERIALS, 2011, 32 (21) :4885-4895
[18]   Synthesis and characterization of carboxylated polybenzimidazole and its use as a highly sensitive and selective enzyme-free H2O2 sensor [J].
Hua, Mu-Yi ;
Chen, Hsiao-Chien ;
Tsai, Rung-Ywan ;
Leu, Yann-Lii ;
Liu, Yin-Chih ;
Lai, Jinn-Tsyy .
JOURNAL OF MATERIALS CHEMISTRY, 2011, 21 (20) :7254-7262
[19]   A novel amperometric sensor for peracetic acid based on a polybenzimidazole-modified gold electrode [J].
Hua, Mu-Yi ;
Chen, Hsiao-Chien ;
Tsai, Rung-Ywan ;
Lin, Yu-Chen .
ELECTROCHIMICA ACTA, 2011, 56 (12) :4618-4623
[20]   Soluble n-doped polyaniline: Synthesis and characterization [J].
Hua, MY ;
Hwang, GW ;
Chuang, YH ;
Chen, SA ;
Tsai, RY .
MACROMOLECULES, 2000, 33 (17) :6235-6238