Comparison of a needle-type and a microdialysis continuous glucose monitor in type 1 diabetic patients

被引:75
作者
Wentholt, IM
Vollebregt, MA
Hart, AA
Hoekstra, JB
DeVries, JH
机构
[1] Acad Med Ctr, Dept Internal Med, NL-1100 AD Amsterdam, Netherlands
[2] Acad Med Ctr, Dept Clin Epidemiol & Biostat, NL-1100 AD Amsterdam, Netherlands
关键词
D O I
10.2337/diacare.28.12.2871
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE - We examined the reliability of two continuous glucose sensors in type 1 diabetic patients at night and during rapid glucose excursions and verified the hypothesized nocturnal hypoglycemic drift of the needle-type sensor (CGMSgold) and delay of the microchalysis sensor (GlucoDay). RESEARCH DESIGN AND METHODS - Blood was sampled overnight twice per hour in 13 patients. Rapid-acting insulin was given subcutaneously 30 min after breakfast. Sampling once per minute started 45 min after breakfast and 75 min After insulin injection for 30 min, with the aim of determining peak and nadir glucose values. Mean absolute differences (MADs) between sensor and blood glucose values were calculated. Sensor curves were modeled for all patients using linear regression. Horizontal and vertical shifts of sensor curves from the blood glucose curves were assessed. A vertical shift indicates sensor drift and a horizontal shift sensor delay. RESULTS- Drift was minimal in the needle-type and microdialysis sensors (-0.02 and - 0.04 mmol/l). Mean +/- SD delay was 7.1 +/- 5.5 min for the microdialysis sensor (P < 0. 001). MAD was 15.0% for the needle-type sensor and 13.6% for the microdialysis sensor (P = 0.013), After correction for the 7-min delay, the microdialysis MAD improved to 11.7% (P < 0.0001). CONCLUSIONS - The microdialysis sensor was more accurate than the needle-type sensor, with or without correction for a 7-min delay. In contrast to the previous version, the current needle-type sensor did not exhibit nocturnal hypoglycemic drift. Continuous subcutaneous glucose sensors are valuable adjunctive tools for glucose trend analyses. However, considering the large MADs, individual sensor values should be interpreted with caution.
引用
收藏
页码:2871 / 2876
页数:6
相关论文
共 17 条
[11]   Evaluating the accuracy of continuous glucose-monitoring sensors [J].
Kovatchev, BP ;
Gonder-Frederick, LA ;
Cox, DJ ;
Clarke, WL .
DIABETES CARE, 2004, 27 (08) :1922-1928
[12]   Continuous subcutaneous glucose monitoring in diabetic patients - A multicenter analysis [J].
Maran, A ;
Crepaldi, C ;
Tiengo, A ;
Grassi, G ;
Vitali, E ;
Pagano, G ;
Bistoni, S ;
Calabrese, G ;
Santeusanio, F ;
Leonetti, F ;
Ribaudo, M ;
Di Mario, U ;
Annuzzi, G ;
Genovese, S ;
Riccardi, G ;
Previti, M ;
Cucinotta, D ;
Giorgino, F ;
Bellomo, A ;
Giorgino, R ;
Poscia, A ;
Varalli, M .
DIABETES CARE, 2002, 25 (02) :347-352
[13]  
Mastrototaro J J, 2000, Diabetes Technol Ther, V2 Suppl 1, pS13, DOI 10.1089/15209150050214078
[14]   Reproducibility of the continuous glucose monitoring system matches previous reports and the intended use of the product [J].
Mastrototaro, JJ ;
Gross, TM .
DIABETES CARE, 2003, 26 (01) :256-256
[15]   Spurious reporting of nocturnal hypoglycemia by CGMS in patients with tightly controlled type I diabetes [J].
McGowan, K ;
Thomas, W ;
Moran, A .
DIABETES CARE, 2002, 25 (09) :1499-1503
[16]   Do sensor glucose levels accurately predict plasma glucose concentrations during hypoglycemia and hyperinsulinemia? [J].
Monsod, TP ;
Flanagan, DE ;
Rife, F ;
Saenz, R ;
Caprio, S ;
Sherwin, RS ;
Tamborlane, WV .
DIABETES CARE, 2002, 25 (05) :889-893
[17]   Evaluating clinical accuracy of systems for self-monitoring of blood glucose by error grid analysis - Comment on constructing the "upper A-line" [J].
Stockl, D ;
Dewitte, K ;
Fierens, C ;
Thienpont, LM .
DIABETES CARE, 2000, 23 (11) :1711-1712