Frequency of Conduction Disturbances After Transcatheter Implantation of an Edwards Sapien Aortic Valve Prosthesis

被引:67
作者
Godin, Matthieu [1 ]
Eltchaninoff, Helene [1 ]
Furuta, Akira [1 ]
Tron, Christophe [1 ]
Anselme, Frederic [1 ]
Bejar, Karim [1 ]
Sanchez-Giron, Carlos [1 ]
Bauer, Fabrice [1 ]
Litzler, Pierre-Yves [2 ]
Bessou, Jean-Paul [2 ]
Cribier, Alain [1 ]
机构
[1] Rouen Univ Hosp, Dept Cardiol, Rouen, France
[2] Rouen Univ Hosp, Dept Cardiothorac Surg, Rouen, France
关键词
ATRIOVENTRICULAR-BLOCK; HEART-VALVE; REPLACEMENT; STENOSIS;
D O I
10.1016/j.amjcard.2010.04.029
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We evaluated the incidence of conduction abnormalities and requirement for permanent pacemaker in patients undergoing transcatheter aortic valve implantation (TAVI) with the Edwards Sapien prosthesis. In 2009, >8,000 patients were treated with TAVI using 1 of the 2 commercialized models of bioprosthesis (Edwards Sapien, Edwards Lifesciences, Irvine, California; and Core Valve, Medtronic, Irvine, California). Occurrence of conduction abnormalities including complete atrioventricular block requiring permanent pacemaker has been reported after TAVI with the 2 models of valve, more frequently with the Core Valve. We analyzed standard 12-lead electrocardiograms of 69 consecutive patients in whom an Edwards Sapien prosthesis was successfully implanted. Electrocardiograms were examined before treatment, at day 1, and at I-month follow-up. Heart rate, PR and QT intervals and QRS duration were measured and the presence of a first-, second-, or third-degree atrioventricular block was documented. There was a slight increase in heart rate and a discrete decrease in QT interval at day 1. These values had returned to baseline values at 1 month. There was no change in PR interval but a transitory increase in QRS duration was noted. Frequency of left bundle branch block increased from 14.5% at baseline to 27.5% at day 1 with a decreased incidence at day 30 (21.3%). Permanent pacemaker was required in only 3 patients (4.3%). In conclusion, in our experience, conductive disorders and requirement of a definitive pacemaker after implantation of an Edwards Sapien aortic bioprosthesis are infrequent. The physical properties of this prosthesis may explain this observation. (C) 2010 Published by Elsevier Inc. (Am J Cardiol 2010;106:707-712)
引用
收藏
页码:707 / 712
页数:6
相关论文
共 25 条
[1]  
Agatiello C, 2006, ARCH MAL COEUR VAISS, V99, P195
[2]  
[Anonymous], 1991, Circulation, V84, P2383, DOI [10.1161/01.CIR.84.6.2383, DOI 10.1161/01.CIR.84.6.2383]
[3]  
Ben Ameur Y., 2006, Annales de Cardiologie et d'Angeiologie, V55, P140, DOI 10.1016/j.ancard.2005.04.017
[4]   Novel therapeutic aspects of percutaneous aortic valve replacement with the 21F CoreValve Revalving™ system [J].
Berry, Colin ;
Asgar, Anita ;
Lamarche, Yoan ;
Marcheix, Bertrand ;
Couture, Pierre ;
Basmadjian, Arsene ;
Ducharme, Anique ;
Laborde, Jean-Claude ;
Cartier, Raymond ;
Bonan, Raoul .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 70 (04) :610-616
[5]   Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis [J].
Cribier, A ;
Eltchaninoff, H ;
Tron, C ;
Bauer, F ;
Agatiello, C ;
Sebagh, L ;
Bash, A ;
Nusimovici, D ;
Litzler, PY ;
Bessou, JP ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (04) :698-703
[6]   Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis - First human case description [J].
Cribier, A ;
Eltchaninoff, H ;
Bash, A ;
Borenstein, N ;
Tron, C ;
Bauer, F ;
Derumeaux, G ;
Anselme, F ;
Laborde, F ;
Leon, MB .
CIRCULATION, 2002, 106 (24) :3006-3008
[7]   Treatment of calcific aortic stenosis with the percutaneous heart valve - Mid-term follow-up from the initial feasibility studies: The French experience [J].
Cribier, A ;
Eltchaninoff, H ;
Tron, C ;
Bauer, F ;
Agatiello, C ;
Nercolini, D ;
Tapiero, S ;
Litzler, PY ;
Bessou, JP ;
Babaliaros, V .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (06) :1214-1223
[8]   Prognostic significance of newly acquired bundle branch block after aortic valve replacement [J].
El-Khally, Z ;
Thibault, B ;
Staniloae, C ;
Theroux, P ;
Dubuc, M ;
Roy, D ;
Guerra, P ;
Macle, L ;
Talajic, M .
AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (08) :1008-1011
[9]   Transcatheter aortic valve implantation: technical aspects, results and indications [J].
Eltchaninoff, H. ;
Zajarias, A. ;
Tron, C. ;
Litzler, P. Y. ;
Baala, B. ;
Godin, M. ;
Bessou, J. P. ;
Cribier, A. .
ARCHIVES OF CARDIOVASCULAR DISEASES, 2008, 101 (02) :126-132
[10]   Percutaneous aortic valve replacement for severe aortic stenosis in high-rick patients using the second- and current third-generation self-expanding CoreValve prosthesis - Device success and 30-day clinical outcome [J].
Grube, Eberhard ;
Schuler, Gerhard ;
Buellesfeld, Lutz ;
Gerckens, Ulrich ;
Linke, Axel ;
Wenaweser, Peter ;
Sauren, Barthel ;
Mohr, Friedrich-Wilhelm ;
Walther, Thomas ;
Zickmann, Bernfried ;
Iversen, Stein ;
Felderhoff, Thomas ;
Cartier, Raymond ;
Bonan, Raoul .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (01) :69-76