Interconnection of Multichannel Polyimide Electrodes Using Anisotropic Conductive Films (ACFs) for Biomedical Applications

被引:21
作者
Baek, Dong-Hyun [1 ,2 ]
Park, Ji Soo [1 ]
Lee, Eun-Joong [1 ]
Shin, SuJung [1 ]
Moon, Jin-Hee [3 ]
Pak, James Jungho [4 ]
Lee, Sang-Hoon [1 ]
机构
[1] Korea Univ, Dept Biomed Engn, Coll Hlth Sci, Seoul 136703, South Korea
[2] Korea Univ, Sch Elect Engn, Seoul 136703, South Korea
[3] Seoul Natl Univ, Interdisciplinary Programs Biomed Engn, Seoul 110799, South Korea
[4] Korea Univ, Sch Elect Engn, Seoul 136701, South Korea
关键词
Biomedical engineering; biomedical electrodes; packaging; polyimide (PI) films; CONTACT RESISTANCE; THETA-RHYTHM; FLIP-CHIP; BIOCOMPATIBILITY; RELIABILITY; URETHANE; DESIGN; SYSTEM; MICE;
D O I
10.1109/TBME.2010.2102020
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper, we propose a method for interconnecting soft polyimide (PI) electrodes using anisotropic conductive films (ACFs). Reliable and automated bonding was achieved through development of a desktop thermocompressive bonding device that could simultaneously deliver appropriate temperatures and pressures to the interconnection area. The bonding conditions were optimized by changing the bonding temperature and bonding pressure. The electrical properties were characterized by measuring the contact resistance of the ACF bonding area, yielding a measure that was used to optimize the applied pressure and temperature. The optimal conditions consisted of applying a pressure of 4 kgf/cm(2) and a temperature of 180 degrees C for 20 s. Although ACF base bonding is widely used in industry (e. g., liquid crystal display manufacturing), this study constitutes the first trial of a biomedical application. We performed a preliminary in vivo biocompatibility investigation of ACF bonded area. Using the optimized temperature and pressure conditions, we interconnected a 40-channel PI multielectrode device for measuring electroencephalography (EEG) signals from the skulls of mice. The electrical properties of electrode were characterized by measuring the impedance. Finally, EEG signals were measured from the mice skulls using the fabricated devices to investigate suitability for application to biomedical devices.
引用
收藏
页码:1466 / 1473
页数:8
相关论文
共 31 条
[1]   Interfacing Conducting Polymer Nanotubes with the Central Nervous System: Chronic Neural Recording using Poly (3,4-ethylenedioxythiophene) Nanotubes [J].
Abidian, Mohammad Reza ;
Ludwig, Kip A. ;
Marzullo, Timothy C. ;
Martin, David C. ;
Kipke, Daryl R. .
ADVANCED MATERIALS, 2009, 21 (37) :3764-3770
[2]   DIELECTRIC ISOLATION OF SILICON BY ANODIC BONDING [J].
ANTHONY, TR .
JOURNAL OF APPLIED PHYSICS, 1985, 58 (03) :1240-1247
[3]  
BAEK DH, 2009, EMBC 2009 ANN INT C, P7022
[4]   A FLEXIBLE PERFORATED MICROELECTRODE ARRAY FOR EXTENDED NEURAL RECORDINGS [J].
BOPPART, SA ;
WHEELER, BC ;
WALLACE, CS .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (01) :37-42
[5]   Characteristic study of anisotropic-conductive film for chip-on-film packaging [J].
Chang, SM ;
Jou, JH ;
Hsieh, A ;
Chen, TH ;
Chang, CY ;
Wang, YH ;
Huang, CM .
MICROELECTRONICS RELIABILITY, 2001, 41 (12) :2001-2009
[6]   Transient thermal analysis of an ACF package assembly process [J].
Chiriac, VA ;
Lee, TYT .
IEEE TRANSACTIONS ON COMPONENTS AND PACKAGING TECHNOLOGIES, 2001, 24 (04) :673-681
[7]   Neural stimulation and recording electrodes [J].
Cogan, Stuart F. .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2008, 10 :275-309
[8]  
FOX SE, 1986, EXP BRAIN RES, V62, P495
[9]   Impedance characterization and modeling of electrodes for biomedical applications [J].
Franks, W ;
Schenker, I ;
Schmutz, P ;
Hierlemann, A .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (07) :1295-1302
[10]  
Harman G., 2009, WIRE BONDING MICROEL