Three-dimensional contrast-enhanced MR angiography sf endovascular covered stents in patients with peripheral arterial occlusive disease

被引:14
作者
Juergens, KU [1 ]
Tombach, B [1 ]
Reimer, P [1 ]
Vestring, T [1 ]
Heindel, W [1 ]
机构
[1] Univ Munster, Dept Clin Radiol, D-48129 Munster, Germany
关键词
D O I
10.2214/ajr.176.5.1761299
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE, Three-dimensional contrast-enhanced MR angiography was performed to study MR characteristics of Hemobahn devices. MATERIALS AND METHODS. Changes in endoluminal signal intensities and the precision of the endoluminal diameter measurement were investigated in phantom studies for different concentrations of gadopentetate dimeglumine. Before and after the Hemobahn devices had been implanted, 10 patients with peripheral arterial occlusive disease were examined on MR imaging and three-dimensional contrast-enhanced MR angiography. RESULTS, Phantom experiments using three-dimensional MR angiography showed stent-related signal void as a dark ring in the axial image orientation, providing a precise delineation of the stent-vessel border (mean endoluminal diameter, 8.2 mm; SD. 0.6 mm). Changes in endoluminal signal intensity were evaluated quantitatively. Stent-related artifacts did not compromise diagnostic imaging quality. All Hemobahn devices were found to be patent without migration of an implanted graft. In one patient, an extensive perigraft reaction (edema and contrast-enhanced perivascular tissue) was postinterventionally detected on MR imaging and corresponded to clinically evident postimplantation symptoms. CONCLUSION. Three-dimensional contrast-enhanced MR angiography is a suitable tool to follow up the implantation of Hemobahn devices and to detect intra- and extraluminal abnormalities.
引用
收藏
页码:1299 / 1303
页数:5
相关论文
共 28 条
[11]  
Link J, 1996, CARDIOVASC INTER RAD, V19, P345
[12]   Iliofemoral arterial occlusive disease: Contrast-enhanced MR angiography for preinterventional evaluation and follow-up after stent placement [J].
Link, J ;
Steffens, JC ;
Brossman, J ;
Graessner, J ;
Hackethal, S ;
Heller, M .
RADIOLOGY, 1999, 212 (02) :371-377
[13]   GADOLINIUM ENHANCED MR IMAGING OF VASCULAR STENTS [J].
MATSUMOTO, AH ;
TEITELBAUM, GP ;
CARVLIN, MJ ;
BARTH, KH ;
SAVIN, MA ;
STRECKER, EP .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (03) :357-361
[14]  
MullerHulsbeck S, 1997, AM J ROENTGENOL, V169, P743
[15]   CLINICAL SAFETY OF GADOPENTETATE DIMEGLUMINE [J].
NELSON, KL ;
GIFFORD, LM ;
LAUBERHUBER, C ;
GROSS, CA ;
LASSER, TA .
RADIOLOGY, 1995, 196 (02) :439-443
[16]   SYMPTOMATIC PERIPHERAL VASCULAR-DISEASE - SELECTION OF IMAGING PARAMETERS AND CLINICAL-EVALUATION WITH MR-ANGIOGRAPHY [J].
OWEN, RS ;
BAUM, RA ;
CARPENTER, JP ;
HOLLAND, GA ;
COPE, C .
RADIOLOGY, 1993, 187 (03) :627-635
[17]   BREATH-HOLD GADOLINIUM-ENHANCED MR-ANGIOGRAPHY OF THE ABDOMINAL-AORTA AND ITS MAJOR BRANCHES [J].
PRINCE, MR ;
NARASIMHAM, DL ;
STANLEY, JC ;
CHENEVERT, TL ;
WILLIAMS, DM ;
MARX, V ;
CHO, KJ .
RADIOLOGY, 1995, 197 (03) :785-792
[18]   DYNAMIC GADOLINIUM-ENHANCED 3-DIMENSIONAL ABDOMINAL MR ARTERIOGRAPHY [J].
PRINCE, MR ;
YUCEL, EK ;
KAUFMAN, JA ;
HARRISON, DC ;
GELLER, SC .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (06) :877-881
[19]   Nephrotoxicity of high-dose gadolinium compared with iodinated contrast [J].
Prince, MR ;
Arnoldus, C ;
Frisoli, JK .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (01) :162-166
[20]   Combined use of ECG-triggered 2D-phase contrast MR angiography and 2D-time-of-flight MR angiography for planning and follow-up before and after angiointervention of pelvic arteries and arteries of the lower limb [J].
Reimer, P ;
Wilhelm, M ;
Lentschig, M ;
Wortler, K ;
Marx, C ;
Allkemper, T ;
Boettger, U ;
Heinecke, A ;
Rummeny, EJ ;
Peters, PE .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 168 (03) :243-249