Theoretical analysis of molecular diffusion in pressure-driven laminar flow in microfluidic channels

被引:215
作者
Kamholz, AE [1 ]
Yager, P [1 ]
机构
[1] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
关键词
D O I
10.1016/S0006-3495(01)76003-1
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The T-sensor is a microfluidic analytical device that operates at low Reynolds numbers to ensure entirely laminar flow. Diffusion of molecules between streams flowing side by side may be observed directly. The pressure-driven velocity profile in the duct-shaped device influences diffusive transport in ways that affect the use of the T-sensor to measure molecular properties. The primary effect is a position-dependent variation in the extent of diffusion that occurs due to the distribution of residence time among different fluid laminae. A more detailed characterization reveals that resultant secondary concentration gradients yield variations in the scaling behavior between diffusive displacement and elapsed time in different regions of the channel. In this study, the time-dependent evolution of analyte distribution has been quantified using a combination of one- and two-dimensional models. The results include an accurate portrayal of the shape of the interdiffusion region in a representative T-sensor assay, calculation of the diffusive scaling law across the width of the channel, and quantification of artifacts that occur when making diffusion coefficient measurements in the T-sensor.
引用
收藏
页码:155 / 160
页数:6
相关论文
共 24 条
[11]   Characterisation of a micro-total analytical system for the determination of nitrite with spectrophotometric detection [J].
Greenway, GM ;
Haswell, SJ ;
Petsul, PH .
ANALYTICA CHIMICA ACTA, 1999, 387 (01) :1-10
[12]  
Happel J., 1983, LOW REYNOLDS NUMBER
[13]   Microfabricated flow chamber for fluorescence-based chemistries and stopped-flow injection cytometry [J].
Hodder, PS ;
Blankenstein, G ;
Ruzicka, J .
ANALYST, 1997, 122 (09) :883-887
[14]   Experimental and theoretical scaling laws for transverse diffusive broadening in two-phase laminar flows in microchannels [J].
Ismagilov, RF ;
Stroock, AD ;
Kenis, PJA ;
Whitesides, G ;
Stone, HA .
APPLIED PHYSICS LETTERS, 2000, 76 (17) :2376-2378
[15]   Quantitative analysis of molecular interaction in a microfluidic channel: The T-sensor [J].
Kamholz, AE ;
Weigl, BH ;
Finlayson, BA ;
Yager, P .
ANALYTICAL CHEMISTRY, 1999, 71 (23) :5340-5347
[16]  
Leveque M, 1928, ANN MINES, V2, P201
[17]   Separation and identification of peptides from gel-isolated membrane proteins using a microfabricated device for combined capillary electrophoresis/nanoelectrospray mass spectrometry [J].
Li, JJ ;
Kelly, JF ;
Chemushevich, I ;
Harrison, DJ ;
Thibault, P .
ANALYTICAL CHEMISTRY, 2000, 72 (03) :599-609
[18]   EXPERIMENTAL EVALUATION OF THE SEPARATION EFFICIENCY IN CAPILLARY ELECTROPHORESIS USING OPEN TUBULAR AND GEL-FILLED COLUMNS [J].
LIU, JP ;
DOLNIK, V ;
HSIEH, YZ ;
NOVOTNY, M .
ANALYTICAL CHEMISTRY, 1992, 64 (13) :1328-1336
[19]   RADIAL MEASUREMENT OF HYDRODYNAMICALLY GENERATED CONCENTRATION PROFILES FOR MOLECULAR-WEIGHT DETERMINATION [J].
MURUGAIAH, V ;
SYNOVEC, RE .
ANALYTICAL CHEMISTRY, 1992, 64 (18) :2130-2137
[20]  
Ruzicka Jaromir., 1988, FLOW INJECTION ANAL, V2nd