Assessment of coronary artery stents by 16 slice computed tomography

被引:99
作者
Gilard, M
Cornily, JC
Pennec, PY
Le Gal, G
Nonent, M
Mansourati, J
Blanc, JJ
Boschat, J
机构
[1] Brest Univ Hosp, Dept Cardiol, Brest, France
[2] Brest Univ Hosp, Dept Internal Med, Brest, France
[3] Brest Univ Hosp, Dept Radiol, Brest, France
关键词
D O I
10.1136/hrt.2004.056010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To analyse coronary stents with multislice spiral computed tomography (MSCT) in comparison with coronary angiography. Patients and methods: 310 patients referred for conventional coronary angiography underwent MSCT on the next day (16 x 0.75 mm cross section, 420 ms rotation, 110 ml contrast agent intravenously at 4 ml/s). Two independent blinded reviewers analysed the MSCT. Results: 143 patients had previous stenting (232 stents) and 190 (82%) of the 232 stents were detected. Intrastent lumen was interpretable in 126 (64%) of the detected stents. Lumen interpretability depended on stent diameter: for stent diameter > 3 mm, 81% of lumens were interpretable, as against 51% with <= 3 mm stent diameter (p < 0.001). Restenosis detection likewise depended on stent diameter: with small stents (<= 3 mm), sensitivity and specificity of MSCT were 54% and 100%, respectively; positive and negative predictive values were 100% and 94%. For stents with > 3 mm diameter, corresponding values were 86%, 100%, 100%, and 99%. Conclusion: 16 slice MSCT allows analysis of in- stent lumen in about half of all stented angioplasties. It performs better when stent diameter is more than 3 mm and may offer a non-invasive alternative to conventional coronary angiography for monitoring stented coronary arteries. Technical progress may improve interpretability and hence increase the yield of MSCT in this application.
引用
收藏
页码:58 / 61
页数:4
相关论文
共 13 条
[1]   Neointimal hyperplasia in carotid stent detected with multislice computed tomography [J].
Cademartiri, F ;
Mollet, N ;
Nieman, K ;
Krestin, GP ;
de Feyter, PJ .
CIRCULATION, 2003, 108 (21) :E147-E147
[2]  
Gilard M, 2004, EUR HEART J, V25, P472
[3]   EXERCISE TESTING AND LEFT MAIN CORONARY-ARTERY STENOSIS - CAN PATIENTS WITH LEFT MAIN DISEASE BE IDENTIFIED [J].
JANOSI, A ;
VERTES, A .
CHEST, 1991, 100 (01) :227-229
[4]   Multislice spiral computed tomography for the detection of coronary stent restenosis and patency [J].
Krüger, S ;
Mahnken, AH ;
Sinha, AM ;
Borghans, A ;
Dedden, K ;
Hoffmann, R ;
Hanrath, P .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2003, 89 (2-3) :167-172
[5]   Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques - A comparative study with intracoronary ultrasound [J].
Leber, AW ;
Knez, A ;
Becker, A ;
Becker, C ;
von Ziegler, F ;
Nikolaou, K ;
Rist, C ;
Reiser, M ;
White, C ;
Steinbeck, G ;
Boekstegers, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (07) :1241-1247
[6]   Coronary artery stents in multislice computed tomography -: In vitro artifact evaluation [J].
Mahnken, AH ;
Buecker, A ;
Wildberger, JE ;
Ruebben, A ;
Stanzel, S ;
Vogt, F ;
Günther, RW ;
Blindt, R .
INVESTIGATIVE RADIOLOGY, 2004, 39 (01) :27-33
[7]  
Maintz D, 2003, INVEST RADIOL, V38, P790, DOI 10.1097/01.rli.0000086495.96457.54
[8]   Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography [J].
Nieman, K ;
Cademartiri, F ;
Lemos, PA ;
Raaijmakers, R ;
Pattynama, PMT ;
de Feyter, PJ .
CIRCULATION, 2002, 106 (16) :2051-2054
[9]   Noninvasive angiographic evaluation of coronary stents with multi-slice spiral computed tomography [J].
Nieman, K ;
Cademartiri, F ;
Raaijmakers, R ;
Pattynama, P ;
de Feyter, P .
HERZ, 2003, 28 (02) :136-142
[10]   Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction [J].
Ropers, D ;
Baum, U ;
Pohle, K ;
Anders, K ;
Ulzheimer, S ;
Ohnesorge, B ;
Schlundt, C ;
Bautz, W ;
Daniel, WG ;
Achenbach, S .
CIRCULATION, 2003, 107 (05) :664-666