Coronary artery stents in multislice computed tomography -: In vitro artifact evaluation

被引:102
作者
Mahnken, AH
Buecker, A
Wildberger, JE
Ruebben, A
Stanzel, S
Vogt, F
Günther, RW
Blindt, R
机构
[1] Rhein Westfal TH Aachen, Dept Diagnost Radiol, D-52074 Aachen, Germany
[2] Rhein Westfal TH Aachen, Inst Med Stat, D-52074 Aachen, Germany
[3] Rhein Westfal TH Aachen, Med Clin 1, D-52074 Aachen, Germany
关键词
stents; multislice CT; CT angiography; artifacts;
D O I
10.1097/01.rli.0000095471.91575.18
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objective: The aim of this study was to systematically compare the ability to assess the coronary artery lumen in the presence of coronary artery stents in multislice spiral CT (MSCT). Methods: Ten different coronary artery stents were examined with 4- and 16-detector row MSCT scanners. For image reconstruction, a standard and a dedicated convolution kernel for coronary artery stent visualization were used. Images were analyzed regarding lumen visibility, intraluminal attenuation, and artifacts outside the stent lumen. Results were compared using repeated-measure analysis of variance. Results: Depending on stent type, scanner hardware, and convolution kernel, artificial lumen narrowing ranged from 20% to 100%. The convolution kernel had the most significant influence on the visibility of the stent lumen. Artificial lumen narrowing and intraluminal attenuation changes decreased significantly using the dedicated convolution kernel. In general, most severe artifacts were caused by gold or gold-coated stents. Conclusions: Independent of the scanner hardware or dedicated convolution kernels, routine evaluation of most coronary artery stents is not yet feasible using MSCT.
引用
收藏
页码:27 / 33
页数:7
相关论文
共 23 条
[1]   Restenosis after coronary stenting in current clinical practice [J].
Antoniucci, D ;
Valenti, R ;
Santoro, GM ;
Bolognese, L ;
Trapani, M ;
Cerisano, G ;
Boddi, V ;
Fazzini, PF .
AMERICAN HEART JOURNAL, 1998, 135 (03) :510-518
[2]   Development of a new biodegradable intravascular polymer stent with simultaneous incorporation of bioactive substances [J].
Blindt, R ;
Hoffmeister, KM ;
Bienert, H ;
Pfannschmitt, O ;
Bartsch, G ;
Thissen, H ;
Klee, D ;
Vom Dahl, J .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1999, 22 (12) :843-853
[3]   Artifact-free in-stent lumen visualization by standard magnetic resonance angiography using a new metallic magnetic resonance imaging stent [J].
Buecker, A ;
Spuentrup, E ;
Ruebben, A ;
Günther, RW .
CIRCULATION, 2002, 105 (15) :1772-1775
[4]   New technical developments in multislice CT, part 2: Sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac Imaging [J].
Flohr, T ;
Bruder, H ;
Stierstorfer, K ;
Simon, J ;
Schaller, S ;
Ohnesorge, B .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (08) :1022-1027
[5]   Coronary artery patency after metallic stent implantation evaluated by multislice computed tomography [J].
Funabashi, N ;
Komiyama, N ;
Yanagawa, N ;
Mayama, T ;
Yoshida, K ;
Komuro, I .
CIRCULATION, 2003, 107 (01) :147-148
[6]   Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: Influence of heart rate on image quality and stenosis detection [J].
Giesler, T ;
Baum, U ;
Ropers, D ;
Ulzheimer, S ;
Wenkel, E ;
Mennicke, M ;
Bautz, W ;
Kalender, WA ;
Daniel, WG ;
Achenbach, S .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (04) :911-916
[7]   Six- and twelve-month results from a randomized, double-blind trial on a slow-release paclitaxel-eluting stent for de novo coronary lesions [J].
Grube, E ;
Silber, S ;
Hauptmann, KE ;
Mueller, R ;
Buellesfeld, L ;
Gerckens, U ;
Russell, ME .
CIRCULATION, 2003, 107 (01) :38-42
[8]   Coronary arterial stents: Safety and artifacts during MR imaging [J].
Hug, J ;
Nagel, E ;
Bornstedt, A ;
Schnackenburg, B ;
Oswald, H ;
Fleck, E .
RADIOLOGY, 2000, 216 (03) :781-787
[9]   Multislice spiral computed tomography for the detection of coronary stent restenosis and patency [J].
Krüger, S ;
Mahnken, AH ;
Sinha, AM ;
Borghans, A ;
Dedden, K ;
Hoffmann, R ;
Hanrath, P .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2003, 89 (2-3) :167-172
[10]   Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation [J].
Maintz, D ;
Juergens, KU ;
Wichter, T ;
Grude, M ;
Heindel, W ;
Fischbach, R .
EUROPEAN RADIOLOGY, 2003, 13 (04) :830-835