Coronary artery stents in multislice computed tomography -: In vitro artifact evaluation

被引:102
作者
Mahnken, AH
Buecker, A
Wildberger, JE
Ruebben, A
Stanzel, S
Vogt, F
Günther, RW
Blindt, R
机构
[1] Rhein Westfal TH Aachen, Dept Diagnost Radiol, D-52074 Aachen, Germany
[2] Rhein Westfal TH Aachen, Inst Med Stat, D-52074 Aachen, Germany
[3] Rhein Westfal TH Aachen, Med Clin 1, D-52074 Aachen, Germany
关键词
stents; multislice CT; CT angiography; artifacts;
D O I
10.1097/01.rli.0000095471.91575.18
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objective: The aim of this study was to systematically compare the ability to assess the coronary artery lumen in the presence of coronary artery stents in multislice spiral CT (MSCT). Methods: Ten different coronary artery stents were examined with 4- and 16-detector row MSCT scanners. For image reconstruction, a standard and a dedicated convolution kernel for coronary artery stent visualization were used. Images were analyzed regarding lumen visibility, intraluminal attenuation, and artifacts outside the stent lumen. Results were compared using repeated-measure analysis of variance. Results: Depending on stent type, scanner hardware, and convolution kernel, artificial lumen narrowing ranged from 20% to 100%. The convolution kernel had the most significant influence on the visibility of the stent lumen. Artificial lumen narrowing and intraluminal attenuation changes decreased significantly using the dedicated convolution kernel. In general, most severe artifacts were caused by gold or gold-coated stents. Conclusions: Independent of the scanner hardware or dedicated convolution kernels, routine evaluation of most coronary artery stents is not yet feasible using MSCT.
引用
收藏
页码:27 / 33
页数:7
相关论文
共 23 条
[11]   Multislice CT angiography of the iliac arteries in the presence of various stents - In vitro evaluation of artifacts and lumen visibility [J].
Maintz, D ;
Fischbach, R ;
Juergens, KU ;
Allkemper, T ;
Wessling, J ;
Heindel, W .
INVESTIGATIVE RADIOLOGY, 2001, 36 (12) :699-704
[12]   Coronary magnetic resonance angiography for assessment of the stent lumen: A phantom study [J].
Maintz, D ;
Botnar, RM ;
Fischbach, R ;
Heindel, W ;
Manning, WJ ;
Stuber, M .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2002, 4 (03) :359-367
[13]  
Möhlenkamp S, 1999, CATHETER CARDIO INTE, V48, P39
[14]   Coronary angiography with multi-slice computed tomography [J].
Nieman, K ;
Oudkerk, M ;
Rensing, BJ ;
van Ooijen, P ;
Munne, A ;
van Geuns, RJ ;
de Feyter, PJ .
LANCET, 2001, 357 (9256) :599-603
[15]   Cardiac imaging by means of electrocardiographically gated multisection spiral CT: Initial experience [J].
Ohnesorge, B ;
Flohr, T ;
Becker, C ;
Kopp, AF ;
Schoepf, UJ ;
Baum, U ;
Knez, A ;
Klingenbeck-Regn, K ;
Reiser, MF .
RADIOLOGY, 2000, 217 (02) :564-571
[16]   Coronary arterial stent patency:: Assessment with electron-beam CT [J].
Pump, H ;
Möhlenkamp, S ;
Sehnert, CA ;
Schimpf, SS ;
Schmidt, A ;
Erbel, R ;
Grönemeyer, DHW ;
Seibel, RMM .
RADIOLOGY, 2000, 214 (02) :447-452
[17]   Angiographic findings of the multicenter Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL) - Sirolimus-eluting stents inhibit restenosis irrespective of the vessel size [J].
Regar, E ;
Serruys, PW ;
Bode, C ;
Holubarsch, C ;
Guermonprez, JL ;
Wijns, W ;
Bartorelli, A ;
Constantini, C ;
Degertekin, M ;
Tanabe, K ;
Disco, C ;
Wuelfert, E ;
Morice, MC .
CIRCULATION, 2002, 106 (15) :1949-1956
[18]   Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction [J].
Ropers, D ;
Baum, U ;
Pohle, K ;
Anders, K ;
Ulzheimer, S ;
Ohnesorge, B ;
Schlundt, C ;
Bautz, W ;
Daniel, WG ;
Achenbach, S .
CIRCULATION, 2003, 107 (05) :664-666
[19]  
*SIEM INC, 2002, SOMATOM 16 APPL GUID, P28
[20]   Multislice spiral computed tomography for in-stent restenosis [J].
Storto, ML ;
Marano, R ;
Maddestra, N ;
Caputo, M ;
Zimarino, M ;
Bonomo, L .
CIRCULATION, 2002, 105 (16) :2005-2005