Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction

被引:726
作者
Ropers, D
Baum, U
Pohle, K
Anders, K
Ulzheimer, S
Ohnesorge, B
Schlundt, C
Bautz, W
Daniel, WG
Achenbach, S
机构
[1] Massachusetts Gen Hosp, Dept Radiol, CIMIT, Boston, MA 02114 USA
[2] Univ Erlangen Nurnberg, Dept Cardiol, D-8520 Erlangen, Germany
[3] Univ Erlangen Nurnberg, Inst Diagnost Radiol, D-8520 Erlangen, Germany
[4] Univ Erlangen Nurnberg, Inst Med Phys, D-8520 Erlangen, Germany
[5] Siemens Med Solut, Forchheim, Germany
关键词
imaging; coronary disease; tomography;
D O I
10.1161/01.CIR.0000055738.31551.A9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-We analyzed the accuracy of multi-detector row spiral computed tomography (MDCT) using a 16-slice CT scanner with improved spatial and temporal resolution, as well as routine premedication with beta-blockers for detection of coronary stenoses. Methods and Results-Seventy-seven patients with suspected coronary disease were studied by MDCT (12x0.75-mm cross-sections, 420 ms rotation, 100 mL contrast agent IV at 5 mL/s). Patients with a heart rate above 60/min received 50 mg atenolol before the scan. In axial MDCT images and multiplanar reconstructions, all coronary arteries and side branches with a diameter of 1.5 mm or more were assessed for the presence of stenoses exceeding 50% diameter reduction. In comparison to invasive coronary angiography, MDCT correctly classified 35 of 41 patients (85%) as having at least 1 coronary stenosis and correctly detected 57 of 78 coronary lesions (73%). After excluding 38 of 308 coronary arteries (left main, left anterior descending, left circumflex, and right coronary artery in 77 patients) classified as unevaluable by MDCT (12%), 57 of 62 lesions were detected, and absence of stenosis was correctly identified in 194 of 208 arteries (sensitivity: 92%; specificity: 93%; accuracy: 93%; positive and negative predictive values: 79% and 97%). Conclusions-MDCT coronary angiography with improved spatial resolution and premedication with oral beta-blockade permits detection of coronary artery stenoses with high accuracy and a low rate of unevaluable arteries.
引用
收藏
页码:664 / 666
页数:3
相关论文
共 12 条
  • [1] Achenbach S, 2001, CIRCULATION, V103, P2535
  • [2] Austen W G, 1975, Circulation, V51, P5
  • [3] New technical developments in multislice CT, part 2: Sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac Imaging
    Flohr, T
    Bruder, H
    Stierstorfer, K
    Simon, J
    Schaller, S
    Ohnesorge, B
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (08): : 1022 - 1027
  • [4] Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: Influence of heart rate on image quality and stenosis detection
    Giesler, T
    Baum, U
    Ropers, D
    Ulzheimer, S
    Wenkel, E
    Mennicke, M
    Bautz, W
    Kalender, WA
    Daniel, WG
    Achenbach, S
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (04) : 911 - 916
  • [5] Visualization of coronary arteries in CT as assessed by a new 16 slice technology and reduced gantry rotation time:: first experiences
    Heuschmid, M
    Küttner, A
    Flohr, T
    Wildberger, JE
    Lell, M
    Kopp, AF
    Schröder, S
    Baum, U
    Schaller, S
    Hartung, A
    Ohnesorge, B
    Claussen, CD
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (06): : 721 - 724
  • [6] Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation
    Jakobs, TF
    Becker, CR
    Ohnesorge, B
    Flohr, T
    Suess, C
    Schoepf, UJ
    Reiser, MF
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (05) : 1081 - 1086
  • [7] Usefulness of multislice spiral computed tomography angiography for determination of coronary artery stenoses
    Knez, A
    Becker, CR
    Leber, A
    Ohnesorge, B
    Becker, A
    White, C
    Haberl, R
    Reiser, MF
    Steinbeck, G
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (10) : 1191 - +
  • [8] Non-invasive coronary angiography with high resolution multidetector-row computed tomography - Results in 102 patients
    Kopp, AF
    Schroeder, S
    Kuettner, A
    Baumbach, A
    Georg, C
    Kuzo, R
    Heuschmid, M
    Ohnesorge, B
    Karsch, KR
    Claussen, CD
    [J]. EUROPEAN HEART JOURNAL, 2002, 23 (21) : 1714 - 1725
  • [9] Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography
    Nieman, K
    Cademartiri, F
    Lemos, PA
    Raaijmakers, R
    Pattynama, PMT
    de Feyter, PJ
    [J]. CIRCULATION, 2002, 106 (16) : 2051 - 2054
  • [10] Coronary angiography with multi-slice computed tomography
    Nieman, K
    Oudkerk, M
    Rensing, BJ
    van Ooijen, P
    Munne, A
    van Geuns, RJ
    de Feyter, PJ
    [J]. LANCET, 2001, 357 (9256) : 599 - 603