Ionic dialysance as a method for the on-line monitoring of delivered dialysis without blood sampling

被引:69
作者
Manzoni, C
DiFilippo, S
Corti, M
Locatelli, F
机构
[1] Dept. of Nephrology and Dialysis, Lecco Hospital, Lecco
[2] Nephrology Division, Hospital of Lecco, 22053 Lecco
关键词
conductivity; direct quantification; effective urea clearance; Kt/V determination; ionic dialysance; urea distribution volume;
D O I
10.1093/oxfordjournals.ndt.a027091
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Background. It is well known that the difference between prescribed and delivered dialysis doses greatly affects the morbidity and mortality of dialysed patients. The on-line monitoring of delivered dialysis is therefore of paramount importance. Recently, a conductivity-based method for determining Kt/V on a routine basis has been proposed. Methods. The study was performed using a specially designed module (Biofeedback Module, COT, Hospal) which, when connected to a dialysis monitor, automatically determines effective ionic dialysance (ID). During three consecutive dialysis sessions, administered to each of eight patients at the same depurative efficiency, we deter-mined Kt/V by using mean effective ionic dialysance and by assuming, as suggested, that urea distribution volume corresponded to 55% of body weight. This method was compared with the gold standard of the direct quantification method. The Kt/V was also calculated by using mean effective ionic dialysance and the volume of urea distribution derived from anthropometric parameters. Results. The Kt/V determined by using mean effective ionic dialysance and by assuming that urea distribution volume corresponded to 55% of body weight was heavily underestimated (-22%). This difference was due to both the overestimate of urea distribution volume (+17%) and underestimate of effective urea clearance (KUeff) (-11%). The mean Kt/V calculated on the basis of ionic dialysance and anthropometric volume was also underestimated (-23%) since this volume was overestimated (+17%). Nevertheless, ionic dialysance and urea clearance proved to be closely correlated (r(2) = 0.89) so that effective urea clearance can be derived according to: Kueff = ID x 0.865 + 39.89. Conclusions. In steady-state patients, once urea distribution volume has been correctly determined by means of direct quantification, effective urea clearance can be easily derived from ionic dialysance and Kt/V calculated on-line at each session, without blood sampling or any additional costs.
引用
收藏
页码:2023 / 2030
页数:8
相关论文
共 19 条
[11]  
MANZONI C, 1995, GIORN IT NEFROL, V69, P264
[12]   CAUSES, KINETICS AND CLINICAL IMPLICATIONS OF POST-HEMODIALYSIS UREA REBOUND [J].
PEDRINI, LA ;
ZEREIK, S ;
RASMY, S .
KIDNEY INTERNATIONAL, 1988, 34 (06) :817-824
[13]   A MODEL FOR NONINVASIVE ESTIMATION OF IN-VIVO DIALYZER PERFORMANCES AND PATIENTS CONDUCTIVITY DURING HEMODIALYSIS [J].
PETITCLERC, T ;
GOUX, N ;
REYNIER, AL ;
BENE, B .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1993, 16 (08) :585-591
[14]  
PETITCLERC T, 1995, NEPHROL DIAL TRANSPL, V10, P212
[15]   AUTOMATIC, NONINVASIVE INTRADIALYTIC CLEARANCE MEASUREMENT [J].
POLASCHEGG, HD .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1993, 16 (04) :185-191
[16]  
RONCO C, 1995, J AM SOC NEPHROL, V6, P612
[17]   SHORTFALLS IN THE DELIVERY OF DIALYSIS [J].
SARGENT, JA .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1990, 15 (05) :500-510
[18]   TOTAL-BODY WATER VOLUMES FOR ADULT MALES AND FEMALES ESTIMATED FROM SIMPLE ANTHROPOMETRIC MEASUREMENTS [J].
WATSON, PE ;
WATSON, ID ;
BATT, RD .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1980, 33 (01) :27-39
[19]   UTILITY OF EXPRESSING SERUM SODIUM PER UNIT OF WATER IN ASSESSING HYPONTREMIA [J].
WAUGH, WH .
METABOLISM, 1969, 18 (08) :706-+