A specific LC/ESI-MS/MS method for determination of 25-hydroxyvitamin D3 in neonatal dried blood spots containing a potential interfering metabolite, 3-epi-25-hydroxyvitamin D3

被引:65
作者
Higashi, Tatsuya [1 ,2 ]
Suzuki, Masahiro
Hanai, Junji [3 ]
Inagaki, Shinsuke
Min, Jun Zhe
Shimada, Kazutake [4 ]
Toyo'oka, Toshimasa
机构
[1] Univ Shizuoka, Sch Pharmaceut Sci, Suruga Ku, Shizuoka 4228526, Japan
[2] Univ Shizuoka, Global COE Program, Suruga Ku, Shizuoka 4228526, Japan
[3] Sapporo City Inst Publ Hlth, Sapporo, Hokkaido 0038505, Japan
[4] Kanazawa Univ, Sendai, Miyagi, Japan
基金
日本学术振兴会;
关键词
Derivatization; Dried blood spot; 3-Epi-25-hydroxyvitamin D-3; 25-Hydroxyvitamin D3; LC/ESI-MS/MS; VITAMIN-D METABOLITES; DIELS-ALDER DERIVATIZATION; LIQUID-CHROMATOGRAPHY; MASS-SPECTROMETRY; SERUM; RISK; BIRTH;
D O I
10.1002/jssc.201000911
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Vitamin D deficiency in an infant is associated with a wide range of adverse health outcomes in later life. A method for the quantification of 25-hydroxyvitamin D-3 [25(OH)D-3, the best-established indicator of vitamin D status] in neonatal dried blood spots (DBSs) using LC/ESI-MS/MS has been developed and validated. The method employed two steps of derivatization, a Diels-Alder reaction with 4-phenyl-1,2,4-triazoline- 3,5-dione followed by acetylation, to enhance the detectability of 25(OH)D-3 in ESIMS/MS and to separate 25(OH)D-3 from 3-epi-25-hydroxyvitamin D-3 [3-epi-25(OH)D-3], a potent interfering metabolite. 25(OH)D-3 was extracted from two DBS punches (3mm in diameter, equivalent to 5.3 mu L of whole blood), purified using an Oasis HLB (R) cartridge, and subjected to derivatization prior to analysis with LC/ESI-MS/MS. 25-Hydroxyvitamin D-4 was used as the internal standard. This method was reproducible (intra-and inter-assay RSDs, <6.9%) and accurate (analytical recovery, 95.2-102.7%), and the LOQ was 3.0 ng/mL. The developed method enabled specific quantification of 25(OH)D-3 in neonatal DBSs and detection of vitamin D deficiency without interference from 3-epi-25(OH)D-3.
引用
收藏
页码:725 / 732
页数:8
相关论文
共 23 条
[1]   Metabolic profiling of major vitamin D metabolites using Diels-Alder derivatization and ultra-performance liquid chromatography-tandem mass spectrometry [J].
Aronov, Pavel A. ;
Hall, Laura M. ;
Dettmer, Katja ;
Stephensen, Charles B. ;
Hammock, Bruce D. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (05) :1917-1930
[2]   ASSESSMENT OF THE FREE FRACTION OF 25-HYDROXYVITAMIN-D IN SERUM AND ITS REGULATION BY ALBUMIN AND THE VITAMIN-D-BINDING PROTEIN [J].
BIKLE, DD ;
GEE, E ;
HALLORAN, B ;
KOWALSKI, MA ;
RYZEN, E ;
HADDAD, JG .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1986, 63 (04) :954-959
[3]  
Cookson R.C., 1971, ORG SYNTH, V51, P121, DOI [10.15227/orgsyn.051.0121, DOI 10.15227/ORGSYN.051.0121, DOI 10.15227/0RGSYN.051.0121]
[4]   Quantitative determination of vitamin D metabolites in plasma using UHPLC-MS/MS [J].
Ding, Shujing ;
Schoenmakers, Inez ;
Jones, Kerry ;
Koulman, Albert ;
Prentice, Ann ;
Volmer, Dietrich A. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (02) :779-789
[5]   Ultrasensitive Quantification of Serum Vitamin D Metabolites Using Selective Solid-Phase Extraction Coupled to Microflow Liquid Chromatography and Isotope-Dilution Mass Spectrometry [J].
Duan, Xiaotao ;
Weinstock-Guttman, Bianca ;
Wang, Hao ;
Bang, Eunjin ;
Li, Jun ;
Ramanathan, Murali ;
Qu, Jun .
ANALYTICAL CHEMISTRY, 2010, 82 (06) :2488-2497
[6]   Progress of liquid chromatography-mass spectrometry in measurement of vitamin D metabolites and analogues [J].
El-Khoury, Joe M. ;
Reineks, Edmunds Z. ;
Wang, Sihe .
CLINICAL BIOCHEMISTRY, 2011, 44 (01) :66-76
[7]   A sensitive LC/MS/MS assay of 250H vitamin D3 and 250H vitamin D2 in dried blood spots [J].
Eyles, Darryl ;
Anderson, Cameron ;
Ko, Pauline ;
Jones, Alun ;
Thomas, Andrew ;
Burne, Thomas ;
Mortensen, Preben Bo ;
Norgaard-Pedersen, Bent ;
Hougaard, David Michael ;
McGrath, John .
CLINICA CHIMICA ACTA, 2009, 403 (1-2) :145-151
[8]   The utility of neonatal dried blood spots for the assessment of neonatal vitamin D status [J].
Eyles, Darryl W. ;
Morley, Ruth ;
Anderson, Cameron ;
Ko, Pauline ;
Burne, Thomas ;
Permezel, Michael ;
Mortensen, Preben B. ;
Norgaard-Pedersen, Bent ;
Hougaard, David M. ;
McGrath, John J. .
PAEDIATRIC AND PERINATAL EPIDEMIOLOGY, 2010, 24 (03) :303-308
[9]   Liquid chromatography-tandem mass spectrometric method for the determination of salivary 25-hydroxyvitamin D3:: a noninvasive tool for the assessment of vitamin D status [J].
Higashi, Tatsuya ;
Shibayama, Yujin ;
Fuji, Mihoko ;
Shimada, Kazutake .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (01) :229-238
[10]   Advances in determination of vitamin D related compounds in biological samples using liquid chromatography-mass spectrometry: A review [J].
Higashi, Tatsuya ;
Shimada, Kazutake ;
Toyo'oka, Toshimasa .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (20) :1654-1661