Management of severe vena cava filter tilting: Experience with Bard G-2 filters

被引:9
作者
Turba, Ulku C. [1 ]
Glaiberman, Craig [2 ]
Picus, Daniel [2 ]
Arslan, Bulent [1 ]
Angle, John F. [1 ]
Matsumoto, Alan H. [1 ]
机构
[1] Univ Virginia Hlth Syst, Dept Radiol, Charlottesville, VA 22908 USA
[2] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, St Louis, MO USA
关键词
D O I
10.1016/j.jvir.2007.11.020
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this article is to discuss the occurrence of abdominal pain associated with severe tilting of the Bard G-2 inferior vena cava filters. Potential reasons for the occurrence of tilting and management of tilting of the filters are discussed.
引用
收藏
页码:449 / 453
页数:5
相关论文
共 14 条
[1]   Initial experience in humans with a new retrievable inferior vena cava filter [J].
Asch, MR .
RADIOLOGY, 2002, 225 (03) :835-844
[2]   Retrievability of the recovery vena cava filter after dwell times longer than 180 days [J].
Binkert, CA ;
Sasadeusz, K ;
Stavropoulos, SW .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 17 (02) :299-302
[3]   A penetrating inferior vena caval filter ... [J].
DuraiRaj, R. ;
Fogarty, S. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2006, 32 (06) :737-739
[4]   Duodenal perforation with an inferior vena cava filter: An unusual cause of abdominal pain [J].
Feezor, RJ ;
Huber, TS ;
Welborn, MB ;
Schell, SR .
JOURNAL OF VASCULAR SURGERY, 2002, 35 (05) :1010-1012
[5]   Difficult retrieval of a recovery IVC filter [J].
Hagspiel, KD ;
Leung, DA ;
Aladdin, M ;
Spinosa, DJ ;
Matsumoto, AH ;
Angle, JF .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2004, 15 (06) :645-647
[6]   Guidelines for the use of retrievable and convertible vena cava filters: Report from the Society of Interventional Radiology multidisciplinary consensus conference [J].
Kaufman, JA ;
Kinney, TB ;
Streiff, MB ;
Sing, RF ;
Proctor, MC ;
Becker, D ;
Cipolle, M ;
Comerota, AJ ;
Millward, SF ;
Rogers, FB ;
Sacks, D ;
Venbrux, AC .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 17 (03) :449-459
[7]  
Kaufman John A, 2004, Tech Vasc Interv Radiol, V7, P96, DOI 10.1053/j.tvir.2004.02.006
[8]   IVC filter tilt and asymmetry: Comparison of the over-the-wire stainless-steel and titanium greenfield IVC filters [J].
Kinney, TB ;
Rose, SC ;
Weingarten, KE ;
Valji, K ;
Oglevie, SB ;
Roberts, AC .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1997, 8 (06) :1029-1037
[9]   Reporting standards for inferior vena caval filter placement and patient follow-up: Supplement for temporary and retrievable/optional filters [J].
Millward, SF ;
Grassi, CJ ;
Kinney, TB ;
Kundu, S ;
Becker, GJ ;
Cardella, JF ;
Martin, LG ;
Silberzweig, JE ;
Sacks, D .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 16 (04) :441-443
[10]   Aortic pseudoaneurysm after penetration by a Simon nitinol inferior vena cava filter [J].
Putterman, D ;
Niman, D ;
Cohen, G .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 16 (04) :535-538