Development of an RSA calibration system with improved accuracy and precision

被引:22
作者
Cai, Rongyi [1 ,2 ]
Yuan, Xunhua [1 ,2 ]
Rorabeck, Cecil [3 ]
Bourne, Robert B. [2 ,3 ]
Holdsworth, David W. [1 ,2 ,4 ]
机构
[1] John P Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
[3] Univ Western Ontario, Dept Surg, Div Orthoped, London, ON N6A 3K7, Canada
[4] Univ Western Ontario, Dept Diagnost Radiol & Nucl Med, London, ON, Canada
基金
加拿大健康研究院;
关键词
radiostereometric analysis (RSA); accuracy and precision; calibration cage; computer simulation; phantom test;
D O I
10.1016/j.jbiomech.2007.11.012
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
In this study, a new radiostereometric analysis (RSA) calibration cage was developed with the aim of improving the accuracy and precision of RSA. This development consisted of three steps: a numerical simulation technique was first used to design the new cage; a synthetic imaging method was then implemented to predict the performance of the designed cage before it was actually fabricated; and an experimental phantom test was finally conducted to verify the actual performance of the new cage and compare with two currently widely used cages. Accuracy was calculated as the 95% prediction intervals from regression analyses between the measured and actual displacements, and precision was defined as the standard deviation of repeated measurements. The final experimental phantom tests showed that the accuracy and precision of the new calibration cage were improved by about 40% over an existing biplanar cage and by about 70% compared to a uniplanar cage design. This new cage can be used with any skeletal joints, in either static or kinematic examination, which is helpful for the standardization of the RSA application. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:907 / 911
页数:5
相关论文
共 29 条
[1]
Technical feasibility and precision of radiostereometric analysis as an outcome measure in canine cemented total hip replacement [J].
Allen, MJ ;
Hartmann, SM ;
Sacks, JM ;
Calabrese, J ;
Brown, PR .
JOURNAL OF ORTHOPAEDIC SCIENCE, 2004, 9 (01) :66-75
[2]
RSA wear measurements with or without markers in total hip arthroplasty [J].
Börlin, N ;
Röhrl, SM ;
Bragdon, CR .
JOURNAL OF BIOMECHANICS, 2006, 39 (09) :1641-1650
[3]
The precision of radiostereometric measurements.: Manual vs. digital measurements [J].
Börlin, N ;
Thien, T ;
Kärrholm, J .
JOURNAL OF BIOMECHANICS, 2002, 35 (01) :69-79
[4]
Experimental assessment of precision and accuracy of radio stereometric analysis for the determination of polyethylene wear in a total hip replacement model [J].
Bragdon, CR ;
Malchau, H ;
Yuan, XH ;
Perinchief, R ;
Kärrholm, J ;
Börlin, N ;
Estok, DM ;
Harris, WH .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2002, 20 (04) :688-695
[5]
Improved RSA accuracy with DLT and balanced calibration marker distributions with an assessment of initial-calibration [J].
Choo, AMT ;
Oxland, TR .
JOURNAL OF BIOMECHANICS, 2003, 36 (02) :259-264
[6]
VersaBond bone cement Prospective randomized study of the clinical properties of a new bone cement in total knee replacement [J].
Dalén, T ;
Nilsson, KG .
KNEE, 2005, 12 (04) :311-317
[7]
The Otto Aufranc Award -: Highly cross-linked polyethylene in Total Hip Arthroplasty -: Randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis [J].
Digas, G ;
Kärrholm, J ;
Thanner, J ;
Malchau, H ;
Herberts, P .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) :6-16
[8]
New polymer materials in total hip arthroplasty - Evaluation with radiostereometry, bone densitometry, radiography and clinical parameters [J].
Digas, G .
ACTA ORTHOPAEDICA, 2005, 76 :4-82
[9]
DIGAS G, 2003, CLIN ORTHOP RELAT R, V417, P126
[10]
Marker Configuration Model-Based Roentgen Fluoroscopic Analysis [J].
Garling, EH ;
Kaptein, BL ;
Geleijns, K ;
Nelissen, RGHH ;
Valstar, ER .
JOURNAL OF BIOMECHANICS, 2005, 38 (04) :893-901